335224-BIM-B-1208
6
Johnson Controls Unitary Products
NOMENCLATURE
D K -10 N18 A T A AA 3 0 1 2 4 A
Product Category
D = A/C, Single Pkg., R-410A
A = Std. Motor
Airflow
B = Std. Motor/Econo./Barometric Relief (Downflow
Only)
C = Std. Motor/Econo./Power Exhaust (Downflow Only)
D = Std. Motor/Motorized Damper (Downflow Only)
E = Std. Motor/Horizontal Economizer (No Baro.)
F = Std. Motor/Slab Econo./Power Exhaust
(Downflow Only)
G = Std. Motor/Slab Econo./Barometric Relief
(Downflow Only)
N = Hi Static
P = Hi Static
/Econo./Barometric Relief
(Downflow Only)
Q = Hi Static
/Econo./Power Exhaust
(Downflow Only)
R = Hi Static
/Motorized Damper (Downflow Only)
S = Hi Static
/Horizontal Economizer (No Baro.)
T = Hi Static
/Slab Econo./Power Exhaust
(Downflow Only)
U = Hi Static
/Slab Econo./Barometric Relief
(Downflow only)
Product Generation
4 = Fourth Generation
C00 = Cooling Only. No heat installed
Heat Type and Nominal Heat Capacity
N12 = 120 MBH Input Aluminized Steel
N18 = 180 MBH Input Aluminized Steel
N24 = 240 MBH Input Aluminized Steel
S12 = 120 MBH Input Stainless Steel
S18 = 180 MBH Input Stainless Steel
S24 = 240 MBH Input Stainless Steel
E09 = 9 KW
E18 = 18 KW
E24 = 24 KW
E36 = 36 KW
E54 = 54 KW
Gas Heat Options
Electric Heat Options
Nominal Cooling Capacity
-07 = 7.5 Ton
-10 = 10.0 Ton
-12 = 12.5 Ton
Product Identifier
K = Reheat
Voltage
T = 208/230-3-60
W = 460-3-60
X = 575-3-60
Product Style
A = Style A
B = Style B
A = No Options Installed
Installation Options
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Options
SS Drain Pan
Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
CPC Controller, DFS, APS
Johnson Controller, DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity IntelliComfort Controller
Simplicity IntelliComfort Controller w/ModLinc
2" Pleated filters
BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)
Shipping Bag
Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned
AA = None
AB = Phase Monitor
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
Additional Options
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator & Condenser Coils
7.5-12.5 Ton Single Package Model Number Nomenclature
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.