PARTS INSTALLATION
NOTES
INDOOR UNIT
INSTALLATION PROCEDURE
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
■
Fixing
• Place the installation guide pattern on the designated
installation place and mark the hole position.
• Drill a hole and mount installation plate.
• After determining the pipe
hole position. Drill the hole
at a slight downward slant
towards the outdoor side.
Outdoor
Indoor
Note: When installing
the refrigerant pipes from
others side. A hole must
be place to allow fall
towards the outdoor unit.
• Make 6 mm 4-6 holes, in the wall at the four corners of mouting
plate (bracket) then insert appropriate mouting devices.
• Install the mounting plate using 4-6 pieces of mounting screw
securely at four corners and tighten the screw completely.
Do not over tighten the screws and deform the back plate.
CAUTIONS
• Ensure that the space around the left and right of the indoor
unit is more than 12cm.
The indoor unit should be installed allowing a minimum clear-
ance of 15cm from the ceiling.
• Use a stud finder to locate studs to prevent unnecessary
damage to the wall.
• A minimum pipe run of 3 metres is required to minimise
vibration & excessive noise.
• The indoor unit should be installed on the wall at a height of
2.3 metres or more from the floor .
• A, B and C directions should be free from obstructions.
5
Remote controller
1
6
Self-tapping screw B ST3.9X10
2
7
Remote controller holder
1
8
Seal
1
9
Drain joint
1
Liquid side
4
Gas side
ø 6.35
ø 9.53 (<12000Btu/h model)
ø 12.7 (21000Btu/h model > Cooling
capacity
f
12000Btu/h model)
ø 16 (
f
21000Btu/h model)
Parts
you
must
purchase
NOTES
• This illustration is for explanation purposes only.
• Copper lines must be insulated independently.
C
B
A
1
2
3
5
4
7
6
Self-tapping screw B
ST3.9X10
Loop the
connective
cable.
Remote Controller
Air F
ilter
Remote Controller
holer
30cm min
imum
200cm
mini
mum
60cm m
inimum
30cm mi
nimu
m
12cm minimum
12c
m min
imum
15cm
minimum
60cm minimum
Except the above parts provided, the other parts needed
during installation you must purchase.
750
45
250
Right refrigerant
pipe hole
65
Installation plate
Indoor unit outline
Left refrigerant
pipe hole
65
150mm or more to ceiling
120mm or more
to wall
120mm or more
to wall
150mm or more to ceiling
Indoor unit outline
Installation plate
920
293
Right refrigerant
pipe hole
65
Left refrigerant
pipe hole
65
120mm or more
to wall
120mm or more
to wall
(
12000Btu/h model)
(
12000Btu/h model)
MODEL 07-12
MODEL 18