![York LDO9624 Parts Manual Download Page 31](http://html1.mh-extra.com/html/york/ldo9624/ldo9624_parts-manual_912563031.webp)
31
YORK INTERNATIONAL
FORM 102.20-RP1(1104)
FIG. 9 - SECURING FANS AND MOTORS
LDO9703
NOTE 3
B
END RL
PLAN VIEW
COMEFRI
FAN
MOT
OR
INDUSTRIAL FAN
DRIVE
COMEFRI FAN
MOTOR
Spring RL
ISO RL WITH STIFF
NOTE 2
MBS RL
NOTE 1
DIRECTION OF AIR FLOW FOR: R, RI
(OPP. DIRECTION FOR F, FI)
NOTES:
1. SECURING FANS:
COMEFRI FAN 7-7 - SEE TABLE 1.
COMEFRI FANS 9-6 TO 32-32 - SEE TABLE 2.
INDUSTRIAL FANS 122 TO 182 - SEE TABLE 2.
INDUSTRIAL FANS 200 TO 330 - SEE TABLE 3.
2. SECURING MOTOR BASES:
BASES USED WITH COMEFRI FANS 7-7 TO 12-9 - SEE TABLE 2.
ALL OTHER BASES - SEE TABLE 3.
3. SECURING MOTORS:
1 H.P. TO 2 H.P. MOTORS - SEE TABLE 1.
3 H.P. THROUGH 10 H.P. MOTORS - SEE TABLE 2.
15 H.P. MOTORS AND UP - SEE TABLE 3.
4. DIMENSION "A" IS THE DISTANCE FROM THE INSIDE EDGE OF
THE RAIL TO THE SIDE OF THE MOTOR BASE RAIL.
DIMENSION "B" IS THE DISTANCE FROM THE FAN'S FRAME TO
THE INSIDE EDGE OF THE END RAIL.
ISO RL
WITH STIFF
END RL
WITH STIFF
MOTOR
BASE
SPRING
RL
NOTE 3
MOTOR
PLENUM FAN
DIRECTION OF AIRFLOW FOR
FRONT INLET
SPRING
RL
ISO RL
PLENUM FAN
END RL
NOTE 1
MOTOR
SPRING
RL
NOTE 2
MOTOR BASE
END RL
COMM RL
ISO STIFF
TOP VIEW
TIE-DOWN
HOLES
NOTE 6
SPRING
RL
END RL
ISOLATOR
NOTE 6
HOLE 1
NOTE 4
HOLE 2
NOTE 4
END RL
END/SPRING/COMM RL
SPRING RL
NOTE 5
NOTE 7
COMM RL
A (NOTE 4)
B (NOTE 4)
NOTES:
1. SECURING FANS:
FANS 121 TO 161 - SEE TABLE 2.
FANS 201 TO 321 - SEE TABLE 3.
FANS 351 TO 551 - SEE TABLE 4.
INDUSTRIAL FANS 200 TO 330 - SEE TABLE 3.
2. SECURING MOTOR BASES:
BASES USED WITH FANS 121 TO 161 - SEE TABLE 2.
ALL OTHER BASES - SEE TABLE 3.
3. SECURING MOTORS:
1 H.P. TO 2 H.P. MOTORS - SEE TABLE 1.
3 H.P. THROUGH 10 H.P. MOTORS - SEE TABLE 2.
15 H.P. MOTORS AND UP - SEE TABLE 3.
4. THIS SKID WILL WORK WITH CLASS 1, 2 & 3 PLENUM FANS
TO DETERMINE WHETHER HOLE 1 OR 2 IS USED: MEASURE THE
CNTR TO CNTR DISTANCE ON THE FAN. THEN MEASURE FROM
HOLE 1 & 2 TO FIND A MATCHING CNTR TO CNTR DISTANCE (DIMENSION A OR B).
NOTE: IN SOME CASES HOLE 1 & 2 ARE IN THE SAME LOCATION.
5. HOLES LOCATED ACROSS FROM ONE ANOTHER (AS SHOWN) ARE USED
FOR MOUNTING THE MOTOR BASE.
6. THE ISOLATOR HOLES CAN BE EASILY IDENTIFIED SINCE THEY ARE LOCATED
EXACTLY IN-BETWEEN THE TIE DOWN HOLES.
7. REMOVE THE FLAT WASHERS, USED WITH THE SNUBBER BOLT, IF THEY
CAUSE ANY ASSY ISSUES WITH THE FAN.
PLENUM MTR BS FAN SKID ASSY
F/R COMEFRI/INDUSTRIAL MTR BH FAN SKID ASSY
B (SEE TABLES 5 & 6)
SIDE VIEW
TOP VIEW
(SEE TABLES 5 & 6) A
Summary of Contents for LDO9624
Page 8: ...FORM 102 20 RP1 1104 YORK INTERNATIONAL 8 TABLE 2 UNIT NOMENCLATURE ENVIORNMENT...
Page 90: ...NOTES...
Page 91: ...NOTES...