Page 6 (of 7)
Fig.5
L
S
T
b) Now the vice can be installed on the workbench. First it must be dismantled into 2 parts by removing
the retaining ring (7) and turning the spindle clockwise (CCW) until the base plate (1) exits the guide
rods (5).
If a spacer is used, it must now be fixed to the bottom side of the workbench and pushed against the
additional rear jaw or workbench collar. For easier installation, you can lightly fix it with 2 wood screws
S
1
∅ 4−5
mm (0,16“-0,2“)
, length
L
1
=
E
(spacer thickness) +
25
mm(
1“
) and then attach to it the base
plate (1) of vice HV, into pre-drilled openings of the base plate itself. Lightly tighten the screws
S
2
to
enable the front jaw to fit correctly and the base plate (1) to meet with the rear jaw or workbench collar,
Fig. 6
L
mm/"
ks
6-8
(0,24"-0,32")
L=T
+50
(
L=T
+2")
5-7
∅
4-6
(0,16"-0,24"
)
Fixing of base plate and spacer
L
1
mm/"
mm/"
ks
ks
L
2
mm/"
L
ks
ks
2
mm/"
HV 515
6
(0,24")
5
(0,2")
HV 516
4-8
(0,16-0,32")
E
+25
(
E
+0,98")
2-4
3-6
(0,12"-0,24")
8
(0,32")
E
+35
(
E
+1,38")
4
6
(0,24")
∅
∅
S
mm/"
S
2
S
1
L
2
L
1
Fig.6
∅
∅
∅
S
1
mm/"
∅
S
2
mm/"