background image

TECHNICAL GUIDE

SPLIT-SYSTEM 
AIR CONDITIONERS

10 SEER – R-22/R-407C – 3 Phase 60 Hz

MODELS:
GCGA36 THRU 76
(3 THRU 6.3 NOMINAL TONS)

Due to continuous product improvement, specifications are 
subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at 

www.ahridirectory.org

 

567173-XTG-A-0310

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The 10 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.

FEATURES

QUALITY CONDENSER COILS -

 The coil is constructed of

copper tubing and enhanced aluminum fins for increased
efficiency and corrosion protection.

Protected Compressor -

 The compressor is internally pro-

tected against high pressure and temperature. This is
accomplished by the simultaneous operation of high pres-
sure relief valve and a temperature sensor which protects the
compressor if undesirable operating conditions occur. A liq-
uid line filter-drier further protects the compressor.

Durable Finish -

 The cabinet is made of pre-painted steel.

The pre-treated galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.

Lower Installed Cost -

 Installation time and costs are

reduced by easy power and control wiring connections.
Available in sweat connect models only. The small base
dimension means less space is required on the ground or
roof.

Top Discharge -

 The warm air from the top mounted fan is

blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.

Low Operating Sound Level -

 The upward air flow carries

the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the rippled fins of the condenser
coil muffle the normal fan motor and compressor operating
sounds.

Low Maintenance -

 Long life permanently lubricated motor-

bearings need no annual servicing.

Easy Service Access -

 Fully exposed refrigerant connec-

tions, and a single panel covering the electrical controls
make for easy servicing of the unit.

Secured Service Valves -

 Secured re-usable service valves

are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.

Summary of Contents for GCGA36 THRU 76

Page 1: ...ier further protects the compressor Durable Finish The cabinet is made of pre painted steel The pre treated galvanized steel provides a better paint to steel bond which resists corrosion and rust cree...

Page 2: ...Rows Deep 1 1 1 1 Fin Inches 18 18 18 18 Liquid Line Set OD Field Installed 3 8 3 8 3 8 1 2 Vapor Line Set OD Field Installed 3 4 7 8 7 8 1 1 8 R 22 Indoor Orifice 0 071 0 079 0 090 TXV R 22 Unit Cha...

Page 3: ...in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt hours during the same period COOLING CAPACITY R 407C With Air Handler Coils Unit Model Air Ha...

Page 4: ...6 9 03 40 68 6 80 6 6 19 76 9 6 61 73 2 7 11 69 3 7 66 65 2 8 22 60 9 8 76 56 2 9 28 45 76 1 87 7 6 35 83 7 6 77 79 7 7 28 75 6 7 84 71 3 8 43 66 8 9 00 61 9 9 55 50 84 1 94 9 6 51 90 6 6 93 86 4 7 45...

Page 5: ...KW 3 86 3 86 3 85 4 06 4 18 4 08 4 03 4 02 4 22 4 30 4 28 4 17 4 16 4 36 4 43 125 T C 24 9 24 1 23 8 27 6 30 4 26 6 24 7 24 4 28 3 30 9 27 9 27 6 24 9 28 6 31 0 S C 24 9 24 1 20 0 20 4 15 6 26 6 24 7...

Page 6: ...KW 5 11 5 06 5 04 5 38 5 65 5 36 5 27 5 24 5 56 5 82 5 59 5 54 5 41 5 72 5 97 125 T C 32 9 31 7 31 7 36 4 41 3 34 3 33 7 32 1 37 0 41 6 35 4 34 9 32 6 37 3 41 9 S C 32 9 31 7 27 5 27 8 21 6 34 3 33 7...

Page 7: ...KW 7 25 7 22 7 18 7 53 7 78 7 51 7 44 7 39 7 70 7 93 7 73 7 59 7 54 7 83 8 08 125 T C 41 2 39 8 40 6 45 7 50 0 42 9 41 3 41 6 46 1 50 4 44 0 41 7 41 4 46 4 50 6 S C 41 2 39 8 34 7 34 7 26 3 42 9 41 3...

Page 8: ...S C 59 9 58 8 52 5 51 9 36 9 61 1 58 0 54 3 53 6 37 3 60 9 59 3 55 7 55 2 37 9 KW 9 31 9 27 8 95 9 18 9 41 9 48 9 40 9 09 9 31 9 54 9 63 9 53 9 20 9 44 9 67 125 T C 56 7 57 2 58 8 66 5 66 6 58 0 55 4...