PHYSICAL DATA - ELECTRIC HEAT ACCESSORIES

PHYSICAL DATA (OUTDOOR UNIT)

PHYSICAL DATA (INDOOR UNIT)

DESCRIPTION

UNIT MODEL

E2FB090

E1FB120

Compressor

1

Rating - tons

7-1/2

10

Fans

Quantity

1

2

Diameter - inches No. of Blades/

24 / 4

22 / 3

Nominal CFM

6000

7600

Fan Motors

2

HP

3/4

1/2

RPM

1100

1100

Coil

Rows Deep x Rows High

2 x 30

2 x 36

Finned Length - inches

90

96

Face Area - square feet

18.75

24.00

Tube (Copper) OD - inches

3/8

3/8

Fins (Aluminum) per inch

18

16

Refrigerant-22 (Lbs.)

Holding Charge

1.0

1.50

Operating Charge

3

14.3

18.8

Pumpdown Capacity

4

19.6

24.6

Unit Weight (Lbs.)

Shipping

355

510

Operating

350

505

1These compressors are fully hermetic.

2

These PSC motors are directly connected to the outdoor fans and have inherent protection, ball bearings and a 48 frame. Rotation (when viewing shaft end of motor) -090 = CW, -120 = CCW.

3

Includes outdoor unit and matched indoor blower unit, but no piping.

4

Based on a 95

°

F ambient.

Description

Nominal Heater Capacity

10 KW

16 KW

26 KW

36 KW

Heater Elements

% Nickel

59.2

% Chromium

16.0

Coil ID - inches

9/32

Watt Density-watts/sq.in.

59

Rows Deep

1

2

3

4

Face Area - square feet

3.0

DESCRIPTION

UNIT MODEL

F3EH090

F3EH120

Coil

Rows Deep x Rows High

3 x 24

3 x 32

Finned Length - inches

45.5

45.5

Face Area - square feet

7.6

10.1

Tube (Copper) OD - inches

3/8

3/8

Fins (Aluminum) per inch

13

13

Centrifugal Blower (Forward Curve)

Diameter x Width - inches

15 X 15

15 X 15

Blower Motor

1

Nominal Rating - HP

1-1/2

2

Filters (Throwaway)

Quantity Per Unit - 16" x 25" x 1"

4

4

Total Face Area - square feet

11.1

11.1

Refrigerant-22 (Lbs.)

Holding Charge

2

-

-

Pumpdown Capacity

5

12.0

16.5

Unit Weight

3

 (lbs.)

Shipping

405

425

Operating

365

385

Accessory Operating Weights (Lbs.)

Electric Heaters

4

10 KW

63

63

16 KW

66

66

26 KW

71

71

36 KW

74

74

Supply Air Plenum

102

102

Base

60

60

Return Air Grille

15

15

Shipping Volume (Basic Unit) - cubic feet

45

45

1All of these 1750 RPM motors have a solid base, a 56 frame, a 1.15 service factor, inherent protection & permanently lubricated ball bearings. Refer to page 6 for additional motor & drive data.

2

Although every indoor unit is shipped with a small holding charge, this charge will be lost during installation. Loss of all refrigerant must be reclaimed during installation-NOT vented into the

  atmosphere. Refer to the above table on the OUTDOOR unit for the system operating charge.

3

Refer to Installation Instruction Form 515.41-N2 for the distributed weight of these indoor units.

4

Refer to the table below for additional electric heat accessory data.

5

Based on a 80

°

F ambient.

515.41-TG1Y

Unitary Products Group

11

Summary of Contents for E2FB090

Page 1: ...heating cycles To eliminate the costly cabinet deterioration problems usually associated with outdoor equipment all sheet metal parts are constructed of commercial grade G90 galvanized steel After fab...

Page 2: ...and defrost cycles condensate will drip from the underside of the unit coils and that this condensate will freeze when the temperature of the outdoor air is below 32 F A gravel bed or some other means...

Page 3: ...120 121 9 0 117 3 0 63 2 1 Outdoor Unit Sound Rating2 bels E2FB090 8 6 E1FB120 9 0 1Ratings are in accordance with ARI Standard 240 2Sound ratings are in accordance with ARI Standard 270 3Deduct 1 MBH...

Page 4: ...71 9 8 51 119 0 101 2 8 88 110 5 96 3 9 93 93 9 91 0 11 00 80 65 5 64 0 60 9 88 0 83 2 77 8 76 55 8 53 7 49 9 74 9 70 0 64 7 72 46 1 43 3 38 9 61 7 56 9 51 5 80 62 82 5 76 8 5 40 74 3 73 7 6 91 66 0 6...

Page 5: ...8 4 98 70 5 5 41 81 0 6 07 91 5 6 86 102 0 7 65 70 20 8 3 53 30 4 4 16 40 0 4 75 51 8 5 15 63 6 5 58 73 2 6 25 82 8 7 05 92 4 7 84 80 17 5 3 72 26 2 4 35 35 0 4 95 45 8 5 36 56 8 5 79 65 5 6 47 74 3 7...

Page 6: ...diagram inside the motor terminal box when the motor leads have to be reconnected for a 208 or 230 volt power supply Motor Specifications 1750 RPM inherently protected 208 230 460 3 60 or 380 415 3 50...

Page 7: ...n be field installed to enhance protection of the unit Thermostats with either manual or automatic changeover are available for precise control of the temperature within the conditioned space The manu...

Page 8: ...CESS 1 3 8 OD SUCTION CONN 5 8 OD LIQUID CONN COMPRESSOR AND CONDENSER FAN MOTOR ACCESS 7 8 KNOCKOUT ACCESSORY WIRING ENTRY 1 3 8 DIA POWER WIRING ENTRY 7 8 DIA CONTROL WIRING ENTRY 32 1 2 5 4 1 8 2 5...

Page 9: ...ctric heater a supply air plenum or a base is used 2This dimension is required for removal of the coil Only 26 is required for normal servicing 3Although no clearance is required for service and opera...

Page 10: ...ACCESSORY DIMENSIONS Nom KW Model Number 10 2HS04501025 46 50 16 2HS04501625 46 50 26 2HS04502625 46 50 36 2HS04503625 46 50 515 41 TG1Y 10 Unitary Products Group...

Page 11: ...3 x 24 3 x 32 Finned Length inches 45 5 45 5 Face Area square feet 7 6 10 1 Tube Copper OD inches 3 8 3 8 Fins Aluminum per inch 13 13 Centrifugal Blower Forward Curve Diameter x Width inches 15 X 15...

Page 12: ...280 415 3 50 37 4 51 8 60 6 283 F3EH120 10 208 3 60 20 8 35 4 40 8 133 230 3 60 24 1 38 6 40 8 134 460 3 60 12 0 19 3 20 12 216 380 3 50 9 5 16 9 20 12 203 415 3 50 10 4 18 6 20 12 202 16 208 3 60 33...

Reviews: