Wired Zone Controller XK41 & XK47
1
2
Fig.3.10.1 Blow Setting
Notes:
①.
When the Blow function is activated, if turning off the unit by pressing On/Off or using the
remote controller, the indoor fan will run at the low fan speed for two minutes
, with “BLOW”
displayed on the LCD. But if the Blow function is deactivated, the indoor fan will turn off
automatically.
②.
Blow function is not available in the Fan or Heating mode.
3.11 Other Functions
a. Lock
Upon start-up of a unit with no
malfunction or under the “Off” state of the unit, press ▲ and ▼ at
the same time for five seconds until the wired zone controller enters the Lock function. In this case,
the LCD displays
.
After that, repress these two buttons at the same time for five seconds to quit this function.
Under the Lock state, any other button pressed
won’t work.
b. Memory
Memory switch-over: In
the “Off” state of the unit, press “Mode” and ▲ at the same time for five
seconds to switch memory states between memory ON and memory OFF. When this function is
activated, Memory will be displayed. If this function is not set, the unit will be in
the “Off” state after
a power failure and then power recovery.
Memory recovery: If this function has been set for the wired zone controller, after a power failure
the wired zone controller will resume its original running state upon power recovery.
Memory contents: On/ Off Mode, set temperature, set fan speed and Lock function.
Press
Function
repeatedly until
reaching the Blow setting status.
Press Function repeatedly until
reaching the Blow setting status again.
Note: It will take about five seconds to save data. Therefore, please do not turn off the power at
this time, or data will not be saved.