background image

356486-UUM-K-0613

Johnson Controls Unitary Products

5

Do not operate the furnace, call a certified dealer or servicing contractor
to check or clean your furnace, or for more information if you have
questions about the operation of your furnace.

If all components appear to be in good operating condition, replace the
furnace access panels/doors. Turn ON the gas and electrical power
supplies to the furnace, and set thermostat to the desired temperature.

How to Clean your Filter

High-velocity filters may be cleaned with a vacuum cleaner or washed
with a garden hose. Be sure to shake off excess water and allow filter to
completely dry before re-installing the filter.

Replace throw away filter(s) with the same size new filter(s). Throw
away filter(s) may be replaced with cleanable filter(s) at this time. 

BLOWER CARE

Even with good filters properly in place, blower wheels and motors will
become dust laden after months of operation. The entire blower assem-
bly should be inspected annually. This service must be performed by a
qualified service agency.

NOTE: 

The spring-loaded safety cut-off switch, mounted at the blower

deck will automatically cut off the electrical power supply to the furnace
when the furnace blower access panel/door is removed. As a safety
precaution, all electrical power and the gas supply to the furnace should
be turned off before servicing.

MOTOR LUBRICATION

The motors in these furnaces are permanently lubricated, and do not
require periodic oiling.

SERVICE INFORMATION

TROUBLESHOOTING PROBLEMS

If your furnace is not operating correctly, the following visual checks
should be made before contacting your local contractor, dealer, or ser-
vice provider.

1.

Check that electrical power to the furnace is turned on.

2.

Check that the manual gas shut-off valve in the gas piping supply is
turned to the ON position. Refer to Figure 8.

3.

Check that the ON/OFF switch on the gas valve is turned to the ON
position. Refer to Figures 9, 10 or 11.

4.

Check that the furnace blower access panel/door is correctly posi-
tioned. The electrical power supply will be cut off if this door is
removed.

FURNACE CONTROL DIAGNOSTICS

The furnace has built-in, self-diagnostic capability. If a system problem
occurs, a blinking LED shows a fault code. The LED can flash red,
green or amber to indicate various conditions. It is located behind a
clear view port in the blower compartment door.

The control continuously monitors its own operation and the operation
of the system. If a failure occurs, the LED will indicate the failure code. If
the failure is internal to the control, the light will stay on continuously. In
this case, the entire control should be replaced, as the control is not
field repairable.

Flash sequence codes 1 through 10 are as follows: LED will turn ON for
1/4 second and OFF for 1/4 second. This pattern will be repeated the
number of times equal to the code. For example, six ON flashes equals
a number 6 fault code. All flash code sequences are broken by a 2 sec-
ond OFF period.

SLOW GREEN FLASH: 

Normal operation.

DOUBLE AMBER FLASH:

 Normal heating operation - Modulating Fur-

nace Models Only

SLOW AMBER FLASH:

 Normal operation with call for heat.

RAPID RED FLASHES:

 There is a problem with the operation of this

furnace. Contact your local dealer, contractor or service provider.

FURNACE MAINTENANCE - DEALER/CONTRACTOR

The furnace should be cleaned and adjusted by a certified dealer or
qualified service contractor once a year or before the start of every
heating season. The following items must be cleaned and serviced or
replaced if there are signs of deterioration.

1.

The vent terminal.

2.

The furnace vent and combustion air intake passageways. Should it
be necessary to service the vent/air intake system, the manufac-
turer recommends this service be conducted by a qualified service
agency. The operation of this appliance requires the reassembly
and resealing of the vent/air intake system.

3.

The furnace burners, ignitor and flame sensor.

4.

The condensate collection and disposal system. If any disassembly
of components containing flue or vent gases is required, a qualified
service agency must perform the service.

5.

Heat exchanger assembly.

6.

Induced draft motor assembly.

REPLACEMENT PARTS LIST

All components, assemblies, accessories, and replacement parts for
this furnace are available through qualified service agencies. It is not
recommended that the user purchase, install, or replace any compo-
nents of this furnace. Contact your local contactor, dealer, or service
provider for additional information.

WIRING DIAGRAM

The unit wiring diagram may be found on the inside of one of the access
panels on the furnace. It is intended for reference only. If service is
required, contact your local contactor, dealer, or service provider.

Make sure you DO NOT move the clip on weight on the
indoor fan wheel when cleaning the wheel. This weight is
used to balance the wheel. Moving the weight will cause the
fan wheel to vibrate.

Summary of Contents for All Residential Multi-position Gas Furnaces(33” Models)

Page 1: ...from the furnace 3 The furnace needs air for combustion in order to operate properly and safely Do not block or obstruct air openings on the furnace air openings to the area where the furnace is inst...

Page 2: ...afety Door Switch Control Board Flue Collar Electrical Junction Box Blower Transformer Capacitor Not used on all models Power Factor Choke Not used on all models Vent Pipe Pressure Switch Manifold Pip...

Page 3: ...gases Next the hot surface ignitor glows and after a warm up period the gas valve opens and ignition occurs A short time later the blower starts and dis tributes the warm air throughout the home When...

Page 4: ...are changed the following items should be visually inspected Check combustion air and vent pipe for blockage or leakage Check all components to be sure they are in good condition and that there are no...

Page 5: ...r compartment door The control continuously monitors its own operation and the operation of the system If a failure occurs the LED will indicate the failure code If the failure is internal to the cont...

Page 6: ...356486 UUM K 0613 6 Johnson Controls Unitary Products NOTES...

Page 7: ...led so that the combustion air is not contaminated by compounds of chlorine fluorine or other damaging chemicals or vapors 4 The product is installed such that the heat exchangers are not exposed to r...

Page 8: ...of the water circuit by foreign material or like causes 13 Damages caused by improper parts components or accessories not suitable for use in or with the unit For a list of parts that are known to be...