ROOM AIR CONDITIONERS

5

IOM # 036 - 3007 TP (0206)

FRESH AIR VENTILATION

This is usually kept in the 
closed position and is used 
only when smoke and / or 
odors are required to be 
cleared from the room. When 
the ventilation lever is pushed 
to ‘CLOSE’, the fresh air 
ventilation is closed, when the 
ventilation is pushed to 
‘OPEN’, the fresh air 
ventilation takes place.

Note: There is some difference 
in the operation method 
between different models. For 
some models, when the 
ventilation lever is pushed 
forward, the fresh air 
ventilation is closed, when it is 
pulled outward, the fresh air 
ventilation is opened. 

 

Note : The VENTILATION LEVER should normally be 
kept in the CLOSED position during cooling for 
maximum cooling effect. 

CLOSE

VENT

OPEN

MAINTENAINCE AND  OPERATIONAL 
CARE

Â

  TO AVOID THE POSSIBILITY OF INJURY, BE SURE 

TO DISCONNECT POWER SUPPLY TO THE UNIT 
BEFORE SERVICING AND / OR CLEANING.

Do Not

 use gasoline, 

benzene, thinner or any other 
chemicals, or insecticide to 
clean the air conditioner, as 
these substances may cause 
flaking off of the paint, and 
cracking or deformation of 
plastic parts.

Never

 attempt to clean the 

unit by pouring water directly 
over any of the surface areas, 
as this will cause deterioration 
of electrical components and 
wiring insulation and it may 
cause a short circuit or 
electrocution.

CLEANING THE AIR FILTER

If the air filter becomes clogged with dust, air flow is 
obstructed which reduces the cooling efficiency. The air filter 
should be cleaned every two weeks.

!

CAUTION

1. Remove 

Air 

Filter (See

Installation Instructions, 
Step 1, on Page 7).

2.  Cleaning the Air Filter

 

Remove the dust clogged 
in the filter by tapping it or 
vacuum clean it. Wash 
the filter well with lukewarm water or a neutral cleaning 
agent.

3.   Cleaning the Air Freshener 

 

The air freshener is fixed 
on the reverse side of the 
air filter, and should be 
cleaned together with the 
air filter. 

  Rinse the filter and 

fresher well using clean 
water. Allow  time  to  dry 
completely.

4. Attaching the Air Filter
See Installation Instructions, Step 5, on Page 7.

 Note 

:

 Never use hot water over 40°C (104°F) to clean 

the air filter and air fresher. Never attempt to operate the 
unit without the air filter.

CLEANING THE FRONT PANEL

During operation, dust may accumulate on the front panel, 
use soft wet cloth with a neutral cleaning agent to wipe it. 
Never use water over 50°C, alcohol, gasoline, acid, solvent 
or brush to clean the front panel as this will damage the 
surface.

END OF SEASON CARE

1.  Operate the fan alone for half a day to dry out any 

moisture from inside the 
unit.

2. Turn  off  power  and 

remove plug from wall 
outlet.

TROUBLE
SHOOTING

Problem : Unit is working, but cooling is not sufficient.

Possible Cause : It is quite 
possible that the supply or 
exhaust grill is blocked. This 
prevents the unit from efficient 
cooling. Remove any 
obstructions.

Possible Cause : The outdoor 
temperature may be 
abnormally high due to the 
unit being exposed to an 
external source of heat.

Summary of Contents for Alaska Y9USC05-5A-F

Page 1: ...cable for the following ALASKA models Y9USC05 5A F Y9USC07 5A F Y9USC09 5A F Y9USE09 5A F Y9USC12 5A F Y9USE12 5A F Y9USC18 5A F Y9USE18 5A F Y9USC21 5A F Y9USC24 5A F Y9USE24 5A F Y9UOC18 5A F Y9UOC2...

Page 2: ...ontact the manufacturer its authorized distributor or service agent if you want to replace it 3 For electrical power supply see the specification on the unit name plate Electrical safety and rules 2 P...

Page 3: ...ns higher than the design conditions may cause the unit to trip or the compressor may burn out 5 If you need to change the location of the unit please contact the York agent or distributor from whom y...

Page 4: ...upwards or downwards always keep the top or bottom blades horizontal This can effectively prevent condensation of water on the front panel of the unit OPERATION DETAILS COOLING ELECTRIC HEATING MODELS...

Page 5: ...h dust air flow is obstructed which reduces the cooling efficiency The air filter should be cleaned every two weeks CAUTION 1 Remove Air Filter See Installation Instructions Step 1 on Page 7 2 Cleanin...

Page 6: ...here is no air flow from the unit Possible Cause The unit may not be working as there may not be any power supply Check for proper connections of the power cable Possible Cause The fuse may be blown C...

Page 7: ...a click Figure 10 ROOM AIR CONDITIONERS 7 IOM 036 3007 TP 0206 Figure 4 Figure 5 Figure 6 Figure 7 Figure 9 Figure 10 Figure 8 DRAINAGE OF CONDENSATE To meet the requirements of different type of app...

Page 8: ...ROOM AIR CONDITIONERS 8 IOM 036 3007 TP 0206...

Page 9: ...C07 5A F Y9USC09 5A F Y9USE09 5A F Y9USC12 5A F Y9USE12 5A F Y9USC18 5A F Y9USE18 5A F Y9USC21 5A F Y9USC24 5A F Y9USE24 5A F Y9UOC18 5A F Y9UOC24 5A F Y9UOC28 5A F Y9ROC18 5A F Y9ROC24 5A F Y9ROC28 5...

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: