background image

SPLIT-SYSTEM 
AIR CONDITIONERS

12 SEER

MODELS:
AC018X12* THRU 060
(1.5 THRU 5 NOMINAL TONS, 1 PH)

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.ariprimenet.org.

LISTED

CERTIFICATION APPLIES ONLY

WHEN THE COMPLETE

SYSTEM IS LISTED

WITH ARI.

ISO 9001

Certified Quality

Management System

R

N

E

M

P

I

U

Q

E

T

Y

R

AT

I

N

U

0

1

2

A R

I

R

A

D

N

A

T

S

D

I

S

N

O

T

C

E

S

F

O

C

C

I

F

I

T

R

E

N

O

I

T

A

HT

I

W

C

G N

I

YL

P

M

O

S

A

I

R

A

O

T

D

E

I

F

I

T

R

E

C

R

E

R

UT

C

A

F

U

N

A

M

C

-

G

NI

N O

I

TI

D

N

O

R

I

A

 

036-21106-005 Rev. B (0505) 

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

 

TECHNICAL
GUIDE 

TECHNICAL
GUIDE 

DESCRIPTION

The 12 SEER Series condensing unit is the outdoor
part of a versatile system of air conditioning. It is
designed to be custom-matched with one of UPG’s
complete line of evaporator sections, each designed to
serve a specific function. Matching Air Handlers are
available for upflow, downflow or horizontal applica-
tions to provide a complete system. Electric Heaters
are available if required. Add-On coils are available for
use with upflow, downflow or horizontal furnaces and
air handlers.

WARRANTY

5-year limited parts warranty.
10-year limited compressor warranty.

FEATURES

• QUALITY CONDENSER COILS - The coil is constructed

of enhanced copper tube and aluminum fins.

• COIL PROTECTION - Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.

• PROTECTED COMPRESSOR - The compressor is inter-

nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.

• DURABLE FINISH - The cabinet is made of pre-painted

steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted textured champagne
finish insure less fading when exposed to sunlight.

• LOWER INSTALLED COST - Installation time and costs

are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Available in sweat connect models only.
The unit contains enough refrigerant for matching indoor
coils and 15 feet of interconnecting piping. The small base
dimension means less space is required on the ground or
roof.

• TOP DISCHARGE - The warm air from the top mounted

fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.

• LOW OPERATING SOUND LEVEL - The upward air flow

carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.

• LOW MAINTENANCE - Long life permanently lubricated

motor-bearings need no annual servicing.

• EASY SERVICE ACCESS - Fully exposed refrigerant con-

nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.

• SECURED SERVICE VALVES - Secured re-usable ser-

vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.

• U.L. and C.U.L. listed - approved for outdoor application.

Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.

Summary of Contents for AC018X1222

Page 1: ...ion of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating condi tions occur A liquid line filter drier further protects the compressor DURABLE F...

Page 2: ...OD 3 8 3 8 3 8 3 8 3 8 3 8 3 8 Vapor Line OD 3 4 3 4 3 4 3 4 7 8 7 8 1 1 8 Unit Charge Lbs Oz 4 4 9 4 7 5 8 5 3 6 13 7 7 8 15 Charge Per Foot Oz 0 68 0 68 0 68 0 68 0 70 0 70 0 76 Operating Weight Lb...

Page 3: ...2 10 703 11 G2FD060 S H 24 T 90 87 15 703 15 703 5 G2FD061H24 T 90 87 19 703 19 703 11 G1HD024 59 53 5 59 4 701 5 701 4 G1HD036 69 59 13 63 11 73 7 701 13 701 11 702 7 G1HD048 81 73 13 78 3 87 4 702 1...

Page 4: ...tal System Charge Base Charge as shipped adder for evaporator adder for line set 5 If the orifice in the evaporator was changed verify the evaporator nameplate has been marked with the correct orifice...

Page 5: ...030 5 8 10 15 18 750 24 0 17 9 12 00 12 00 11 10 AC030X1222 F2RC F2FC030 5 8 10 15 18 1000 29 8 21 5 12 00 12 00 11 00 F2RC F2FC036 5 8 10 15 21 1000 31 0 22 4 12 25 12 25 11 30 F2RP F2FP030 5 8 10 15...

Page 6: ...16 9 12 00 12 00 11 00 14 G1UA036S14 750 24 2 17 6 12 00 12 00 11 25 17 21 G1UA036S17 21 750 24 0 17 3 12 00 12 00 11 10 14 17 G2FD024 S H 14 17 750 23 6 16 9 12 00 12 00 11 00 17 G2FD030 S H 17 750 2...

Page 7: ...5 30 3 12 00 10 65 21 G1HA048H21T 1400 40 7 29 7 12 00 10 65 G1HD048 1400 41 5 29 7 12 00 10 60 21 G1NA048S21D 1400 41 0 28 6 12 00 10 40 17 G1UA048S17 1400 42 0 30 2 12 00 10 60 21 G1UA048S21 1400 4...

Page 8: ...UND POWER RATINGS Rated in accordance with ARI Standard 270 COOLING PERFORMANCE MODEL SUCT T P COMPR AIR TEMP ON CONDENSER MODEL SUCT T P COMPR AIR TEMP ON CONDENSER 75 F 95 F 115 F 75 F 95 F 115 F TE...

Page 9: ...L OPENING S WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL NOTE ALL OUTDOOR WIRING MUST BE WEATHERPROOF ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE NEC AND OR LOCAL CODES POWER WIRING 20...

Page 10: ...5 13 4 KW 1 37 1 35 1 34 1 37 1 36 1 35 1 38 1 37 1 36 95 T C 19 5 18 1 15 8 20 0 19 2 16 7 20 5 19 5 17 7 S C 11 7 11 3 10 4 13 2 13 0 12 0 14 7 14 2 13 6 KW 1 47 1 45 1 43 1 48 1 47 1 45 1 49 1 48...

Page 11: ...84 1 92 1 89 1 86 1 93 1 90 1 88 105 T C 22 9 20 8 18 2 23 3 21 4 19 1 23 8 22 0 20 0 S C 14 5 13 8 12 9 16 3 16 0 15 0 18 1 18 1 17 2 KW 2 04 2 01 1 96 2 07 2 02 1 98 2 09 2 04 2 00 115 T C 21 3 18 6...

Page 12: ...3 28 2 26 8 24 6 27 9 27 8 26 8 S C 18 7 17 7 16 2 20 4 20 1 18 7 22 2 22 1 21 2 KW 2 53 2 45 2 40 2 53 2 49 2 44 2 53 2 51 2 48 115 T C 26 3 23 0 19 7 27 5 24 2 20 7 28 6 25 5 21 8 S C 17 9 16 7 15...

Page 13: ...1 2 67 105 T C 31 8 29 5 27 2 32 3 30 0 27 6 32 9 30 5 28 0 S C 22 6 21 6 20 5 24 8 23 7 22 5 26 9 25 8 24 5 KW 2 93 2 88 2 82 2 94 2 90 2 85 2 96 2 92 2 87 115 T C 29 6 27 2 24 8 30 1 27 6 25 1 30 6...

Page 14: ...9 2 44 8 43 0 39 8 45 0 43 4 40 4 S C 28 0 27 6 26 5 29 3 29 5 28 6 30 7 31 4 30 7 KW 3 07 3 06 3 05 3 08 3 07 3 06 3 09 3 07 3 06 105 T C 43 7 41 0 37 4 43 9 41 5 38 1 44 2 42 0 38 9 S C 28 4 27 6 25...

Page 15: ...31 2 29 3 35 8 34 1 31 5 38 4 36 5 33 7 KW 3 74 3 62 3 57 3 76 3 56 3 57 3 78 3 69 3 58 105 T C 44 7 40 0 35 8 45 4 41 0 36 5 46 1 42 0 37 1 S C 31 9 29 8 27 8 34 5 32 2 29 9 37 0 34 7 32 1 KW 4 01 3...

Page 16: ...7 58 6 63 2 50 3 55 5 59 3 64 1 50 8 55 9 59 8 64 5 S C 43 2 41 0 42 0 41 8 45 5 43 2 44 5 44 2 47 1 44 7 46 3 45 8 KW 10 3 11 2 11 8 12 6 10 2 11 1 11 8 12 6 10 2 11 0 11 7 12 5 105 T C 47 2 52 2 55...

Page 17: ...LOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE APPLICAT...

Page 18: ...036 21106 005 Rev B 0505 18 Unitary Products Group NOTES...

Page 19: ...036 21106 005 Rev B 0505 Unitary Products Group 19 NOTES...

Page 20: ...without notice Printed in U S A 036 21106 005 Rev B 0505 Copyright by York International Corp 2005 All rights reserved Supersedes 036 21106 005 Rev A 0904 Unitary 5005 Norman Products York OK Group D...

Reviews: