background image

®  

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

251934-YTG-J-0910

TECHNICAL GUIDE

Description

YORK

®

 ZJ Series Sunline Magnum

 /ZR Series 

MagnaDRY™/ZF Series Sunline™ units are convertible single 
package high efficiency rooftops. All models have independent 
refrigeration circuits for efficient part load operation.

Although the units are primarily designed for curb mounting on 
a roof, they can also be slab-mounted at ground level or set on 
steel beams above a finished roof.

All ZJ/ZR/ZF units are self-contained and assembled on rigid 
full perimeter base rails allowing for overhead rigging. Every 
unit is completely charged, wired, piped, and tested at the 
factory to provide a quick and easy field installation.

All models (including those with an economizer) are convertible 
between bottom and horizontal duct connections.

ZJ/ZR/ZF units are available in the following configurations: 
cooling only, cooling with electric heat, and cooling with gas 
heat. Electric heaters are available as factory-installed options 
only.

Tested in accordance with:

R-410A
ZJ/ZR/ZF SERIES
15 - 25 TON
60 Hertz

ZJ/ZR Shown

                   

                   

Summary of Contents for 251934-YTG-J-0910

Page 1: ...steel beams above a finished roof All ZJ ZR ZF units are self contained and assembled on rigid full perimeter base rails allowing for overhead rigging Every unit is completely charged wired piped and...

Page 2: ...of Contents Description 1 Table of Contents 2 Component Location 3 Nomenclature 4 Features and Benefits 5 Guide Specifications 9 Physical Data 15 Capacity Performance 21 Airflow Performance 49 Sound...

Page 3: ...r Motor Electric Heater Location Optional Electric Electric Units Belt Drive Blower Motor 14 Gauge Base Rails with Lifting Holes Filter Drier Solid Core Thermal Expansion Valve Copper Tube Aluminum Fi...

Page 4: ...APS Johnson Controller UNT 1126 N2 protocol DFS APS Honeywell Controller DFS APS Novar Controller DFS APS Simplicity IntelliComfort Controller Simplicity IntelliComfort Controller Simplicity LINC York...

Page 5: ...option The assembly includes a rain hood with a damper that can be set for 10 15 or 25 outdoor air With bottom duct connections the fixed outdoor air intake assembly should be mounted over the opening...

Page 6: ...air and determines when the air is cool enough and dry enough to provide free cooling The rainhood is painted to match the basic unit and must be field assembled before installing BAS Ready Economizer...

Page 7: ...s a switch sized to the largest electric heat available for the particular unit is provided Factory installed option only Double Wall Construction Optional double wall construction is available to pro...

Page 8: ...ch the basic unit and must be field assembled before installing Motorized Outdoor Air Intake Damper Includes a slide in plug in damper assembly with a 2 position spring return motor actuator which ope...

Page 9: ...mounted installation The 15 ton unit shall have a minimum EER rating of 12 4 The 17 5 ton unit shall have a minimum EER rating of 12 1 The 20 ton unit shall have a minimum EER rating of 11 6 The 25 to...

Page 10: ...system shall provide at least 15 F of sub cooling at design conditions e All models shall have four independent circuits f Hot gas bypass option shall be factory installed on compressor 1 discharge l...

Page 11: ...that matches the exterior of the unit Water eliminator filters shall be provided Simultaneous economizer compressor operation is also possible Dampers shall fully close on power loss Motorized Outdoo...

Page 12: ...t calls for second stage cooling the RCB senses a signal through Y1 Y2 and engages circuit 1 and circuit 2 in the cooling mode Indoor blower operation is initiated upon a call for first stage cooling...

Page 13: ...TG J 0910 Johnson Controls Unitary Products 13 Reheat Control Board Reheat Controls Part 1 R Y1 Y2 G W1 OCC C W2 P4 P5 P6 P3 COM HGRR HGR HUM K1 K2 K4 K3 MODE SELECTION JUMPER DEHUMIDISTAT HARNESS CON...

Page 14: ...roducts Reheat Controls Part 2 UCB UNIT CONTROL BOARD RHB REHEAT CONTROL BOARD RHTB REHEAT TERMINAL BLOCK HUM HUMIDIFY TERMINAL RHR REHEAT RELAY REHEAT SOLENOID 3 REHEAT SOLENOID 1 REHEAT SOLENOID 2 R...

Page 15: ...40 320 240 320 240 320 240 320 AFUE Steady state efficiency 80 80 80 80 80 80 80 80 No burners 6 8 6 8 6 8 6 8 No stages 2 2 2 2 2 2 2 2 Temperature Rise Range F 20 50 30 60 20 50 30 60 20 50 30 60 20...

Page 16: ...15 18 X 15 Type Centrifugal Centrifugal Centrifugal Centrifugal Motor Sheave 1VP65 1VP65 1VP60 1VP60 1VP60 1VP60 1VP60 1VP75X 1VP75X Blower Sheave BK110 BK090 BK110 BK090 BK110 BK090 1B5V94 1B5V110 1...

Page 17: ...burners 6 8 6 8 6 8 No stages 2 2 2 2 2 2 Temperature Rise Range F 20 50 30 60 20 50 30 60 20 50 30 60 Gas Limit Setting F 195 195 195 195 195 195 Gas piping connection in 1 1 1 1 1 1 DIMENSIONS inche...

Page 18: ...5 18 X 15 18 X 15 Type Centrifugal Centrifugal Centrifugal Motor Sheave 1VP65 1VP65 1VP60 1VP60 1VP60 1VP75X 1VP75X Blower Sheave BK110 BK090 BK110 BK090 1B5V94 1B5V110 1B5V94 Belt BX85 BX81 BX78 BX75...

Page 19: ...80 80 80 80 80 No burners 6 8 6 8 6 8 6 8 No stages 2 2 2 2 2 2 2 2 Temperature Rise Range F 20 50 30 60 20 50 30 60 20 50 30 60 20 50 30 60 Gas Limit Setting F 195 195 195 195 195 195 195 195 Gas pip...

Page 20: ...BX85 BX81 BX78 BX75 BX78 BX75 BX78 5VX840 5VX860 Motor HP each 5 5 5 7 5 5 7 5 7 5 10 15 RPM 1725 1725 1725 1725 1725 1725 1725 1725 1725 Frame size 184T 184T 184T 213T 184T 213T 213T 215T 254T FILTE...

Page 21: ...0 5 152 4 124 3 96 3 67 225 5 10 2 225 5 194 5 166 9 139 3 111 6 212 9 11 6 212 9 191 0 162 9 134 8 106 7 62 208 2 10 1 208 2 208 2 208 2 180 6 152 9 125 3 197 1 11 5 197 1 197 1 197 1 169 0 140 9 112...

Page 22: ...106 7 80 9 157 0 18 1 157 0 152 6 126 8 100 9 75 1 62 158 1 16 3 158 1 158 1 162 5 136 7 110 9 85 1 145 8 18 0 145 8 145 8 145 8 129 5 103 6 77 8 57 159 3 16 3 159 3 159 3 157 2 131 4 105 6 79 8 148...

Page 23: ...7 12 0 262 7 234 8 201 5 168 1 134 8 246 5 13 5 246 5 229 7 195 7 161 8 127 8 62 227 5 11 7 227 5 227 5 227 5 194 2 160 8 127 5 224 9 13 4 224 9 224 9 224 9 190 9 157 0 123 0 57 239 2 11 8 239 2 239 2...

Page 24: ...3 4 154 0 124 7 95 3 172 5 20 9 172 5 172 5 147 9 118 5 89 0 62 185 9 19 0 185 9 185 9 180 1 150 8 121 5 92 1 173 0 20 9 173 0 173 0 168 3 138 8 109 3 79 8 57 184 3 18 9 184 3 184 3 180 5 151 1 121 8...

Page 25: ...3 307 3 260 5 224 3 188 0 151 8 288 4 16 2 288 4 252 8 216 6 180 3 144 1 62 284 5 14 1 284 5 284 5 270 0 233 8 197 6 161 3 270 8 16 0 270 8 270 8 262 2 226 0 189 7 153 4 57 276 1 14 3 276 1 276 1 276...

Page 26: ...7 8 175 3 142 8 110 3 198 3 24 8 198 3 198 3 167 8 134 9 102 0 62 209 0 22 5 209 0 209 0 208 4 175 9 143 4 110 9 192 7 24 8 192 7 192 7 192 7 163 9 131 0 98 1 57 208 1 22 5 208 1 208 1 206 8 174 3 141...

Page 27: ...68 0 333 1 305 4 277 8 250 1 346 8 23 1 346 8 317 5 287 8 258 1 228 4 62 342 2 21 2 342 2 342 2 342 2 314 5 286 9 259 2 322 2 22 7 322 2 322 2 322 2 292 5 262 8 233 1 57 328 7 20 9 328 7 328 7 328 7 3...

Page 28: ...276 5 249 3 215 6 182 0 148 4 253 4 32 1 253 4 240 5 207 3 174 1 140 9 62 258 6 28 9 258 6 258 6 267 4 233 8 200 1 166 5 238 2 31 6 238 2 238 2 238 2 224 8 191 6 158 4 57 254 7 29 0 254 7 254 7 282 7...

Page 29: ...0 127 7 90 5 67 232 3 11 5 232 3 208 9 171 7 134 4 97 2 218 2 12 7 218 2 204 6 167 3 130 1 92 8 62 214 5 11 3 214 5 214 5 214 5 177 3 140 0 102 7 201 9 12 5 201 9 201 9 201 9 164 6 127 4 90 1 57 211...

Page 30: ...161 2 16 8 161 2 161 2 157 7 128 5 99 4 70 2 150 2 18 4 150 2 150 2 146 3 117 1 88 0 58 8 6750 72 190 0 17 1 170 7 137 5 104 2 71 0 175 2 18 6 164 4 131 2 98 0 64 8 67 172 6 17 0 172 6 167 6 141 5 10...

Page 31: ...13 1 110 0 106 8 56 8 25 0 107 2 8 9 107 2 105 0 94 6 48 9 20 0 7500 72 156 9 10 2 146 7 10 8 67 141 0 9 4 92 8 55 6 18 3 131 8 10 0 87 8 50 6 13 3 62 122 5 8 5 112 9 110 0 85 0 65 0 115 1 9 2 107 4 1...

Page 32: ...0 9 47 7 14 4 83 6 12 0 83 6 75 4 42 2 9 0 57 89 6 11 1 89 6 87 0 58 2 24 9 83 8 11 9 90 0 83 4 46 0 17 0 7500 72 115 9 12 5 105 7 13 1 67 104 3 11 9 72 8 35 5 95 1 12 5 67 8 30 5 62 92 9 11 3 91 0 85...

Page 33: ...7 301 4 258 9 209 2 159 5 109 9 282 3 16 2 282 3 254 1 204 4 154 7 105 0 62 273 9 14 6 273 9 273 9 260 1 210 4 160 8 111 1 259 7 16 0 259 7 259 7 252 2 202 5 152 8 103 2 57 270 8 14 4 270 8 270 8 270...

Page 34: ...66 8 57 207 3 21 2 207 3 207 3 187 2 148 4 109 5 70 6 193 6 23 1 193 6 193 6 164 6 125 7 86 8 47 9 9000 72 244 2 21 5 217 3 173 0 128 8 84 5 223 8 23 3 207 9 163 6 119 4 75 1 67 223 2 21 3 223 2 220 7...

Page 35: ...9 1 11 0 149 1 148 4 104 1 59 8 15 6 139 5 11 8 139 5 138 7 94 4 50 1 5 8 10000 72 180 6 12 8 37 7 169 7 13 5 32 4 67 165 5 12 0 124 4 51 4 1 7 155 0 12 8 114 8 46 5 62 159 0 11 1 138 0 129 7 80 0 30...

Page 36: ...19 5 14 4 98 0 95 2 50 9 6 6 109 1 15 2 95 0 89 4 45 1 0 8 57 110 7 14 3 110 7 109 5 65 2 20 9 101 1 15 1 101 1 99 8 55 5 11 2 10000 72 137 1 15 7 16 7 126 3 16 5 11 5 67 123 7 15 0 86 0 31 7 113 2 15...

Page 37: ...370 6 314 9 252 8 190 7 128 6 347 6 23 0 347 6 306 8 244 7 182 6 120 5 62 337 7 20 6 337 7 337 7 303 9 241 8 179 7 117 6 319 8 22 3 319 8 319 8 292 6 230 5 168 4 106 3 57 332 2 20 6 332 2 332 2 317 0...

Page 38: ...133 0 84 4 57 250 4 28 5 250 4 250 4 244 1 195 5 146 9 98 3 231 0 31 1 231 0 231 0 224 9 176 3 127 7 79 1 11250 72 307 0 29 9 263 0 207 6 152 3 96 9 283 0 32 7 246 1 190 8 135 4 80 1 67 278 3 29 5 278...

Page 39: ...9 25 3 159 9 16 0 150 0 141 8 83 9 21 9 12500 72 199 6 18 0 65 6 55 0 190 8 19 2 64 2 52 0 67 175 0 17 4 99 8 85 0 169 0 18 6 94 4 80 0 62 166 9 16 4 137 0 135 0 53 8 27 2 159 7 17 6 126 0 104 0 50 3...

Page 40: ...4 65 0 9 6 62 136 2 20 4 120 0 99 0 40 0 127 5 21 6 120 0 91 0 35 7 57 131 5 18 6 131 5 125 0 69 0 12 0 122 1 21 2 122 1 119 4 64 0 8 7 12500 72 164 4 23 0 60 0 43 0 155 7 24 2 58 6 40 0 67 151 0 22 3...

Page 41: ...2 126 4 99 6 67 227 8 11 7 227 8 194 4 167 5 140 6 113 7 212 2 12 9 212 2 194 0 167 2 140 4 113 6 62 208 0 11 4 208 0 208 0 208 0 181 1 154 2 127 3 194 3 12 7 194 3 194 3 194 3 167 5 140 7 113 9 57 26...

Page 42: ...107 5 84 5 150 4 18 3 150 4 147 3 124 4 101 6 78 7 62 151 4 16 7 151 4 151 4 139 3 116 3 93 2 70 2 138 4 18 1 138 4 138 4 122 5 99 7 76 8 53 9 57 157 5 16 8 157 5 157 5 153 9 130 9 107 9 84 9 146 7 1...

Page 43: ...14 2 259 6 232 5 200 7 168 8 137 0 243 7 15 6 243 7 222 6 191 6 160 5 129 4 62 240 1 14 1 240 1 240 1 240 1 208 2 176 4 144 6 225 0 15 4 225 0 225 0 225 0 194 0 162 9 131 8 57 241 5 14 0 241 5 241 5 2...

Page 44: ...5 4 127 1 98 7 179 4 21 7 179 4 179 4 150 5 121 4 92 3 62 185 5 19 9 185 5 185 5 180 8 152 4 124 1 95 7 174 5 21 6 174 5 174 5 168 7 139 6 110 5 81 4 57 184 0 19 9 184 0 184 0 183 1 154 7 126 3 97 9 1...

Page 45: ...317 0 279 3 235 1 190 9 146 7 299 0 21 2 299 0 264 8 225 1 185 5 145 8 62 290 5 19 0 290 5 290 5 284 7 240 5 196 3 152 1 275 5 20 8 275 5 275 5 272 6 232 9 193 2 153 5 57 283 0 18 9 283 0 283 0 283 0...

Page 46: ...13 3 184 5 155 6 126 8 230 3 29 1 230 3 207 4 178 5 149 7 120 8 62 227 6 26 5 227 6 227 6 223 7 194 9 166 0 137 2 212 0 28 6 212 0 212 0 212 0 185 7 156 8 127 9 57 228 7 26 6 228 7 228 7 225 1 196 2 1...

Page 47: ...343 6 305 9 258 1 210 3 162 5 324 5 22 5 324 5 296 7 250 1 203 4 156 8 62 319 2 20 0 319 2 319 2 319 2 271 4 223 6 175 8 301 0 22 0 301 0 301 0 301 0 254 4 207 7 161 1 57 308 1 20 1 308 1 308 1 308 1...

Page 48: ...29 0 271 7 246 4 212 4 178 5 144 5 249 0 31 1 249 0 236 7 203 4 170 1 136 8 62 259 7 28 6 259 7 259 7 256 6 222 7 188 7 154 8 242 9 30 8 242 9 242 9 242 9 209 6 176 3 142 9 57 257 9 28 9 257 9 257 9 2...

Page 49: ...rmance includes gas heat exchangers and 2 filters See STATIC RESISTANCE table for additional applications 2 See RPM SELECTION table to determine desired motor sheave setting and to determine the maxim...

Page 50: ...4 85 6000 699 2 11 735 2 60 772 3 06 808 3 49 844 3 88 879 4 24 913 4 55 946 4 80 977 5 01 1007 5 15 1036 5 24 1062 5 25 6400 719 2 55 756 3 03 792 3 49 828 3 92 864 4 32 899 4 67 933 4 98 966 5 24 99...

Page 51: ...7 14 35 1129 14 92 1160 15 47 1192 15 98 1223 16 47 1255 16 94 High Static 15 HP Drive Air Flow CFM Available External Static Pressure IWG1 1 Blower performance includes gas heat exchangers and 2 filt...

Page 52: ...es gas heat exchangers and 2 filters See STATIC RESISTANCE table for additional applications 2 See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous...

Page 53: ...53 1017 4 67 1045 4 74 1071 4 75 6000 734 2 25 770 2 70 806 3 13 841 3 53 877 3 90 911 4 23 944 4 52 977 4 77 1008 4 96 1038 5 09 1066 5 17 1092 5 18 6400 757 2 71 793 3 17 829 3 60 864 4 00 899 4 37...

Page 54: ...includes gas heat exchangers and 2 filters See STATIC RESISTANCE table for additional applications 2 See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum cont...

Page 55: ...ide Duct Air Flow CFM Available External Static Pressure IWG1 1 Blower performance includes gas heat exchangers and 2 filters See STATIC RESISTANCE table for additional applications 2 See RPM SELECTIO...

Page 56: ...12200 1212 15 90 1244 16 34 1276 16 75 1308 17 14 High Static 15 HP Drive 15 HP Field Supplied Drive Air Flow CFM Available External Static Pressure IWG1 1 Blower performance includes gas heat exchang...

Page 57: ...5 HP Field Supplied Drive ZR240 20 Ton Bottom Duct Air Flow CFM Available External Static Pressure IWG1 1 Blower performance includes gas heat exchangers and 2 filters See STATIC RESISTANCE table for...

Page 58: ...10 48 1110 10 89 1141 11 28 1172 11 64 1203 11 99 1234 12 32 1265 12 64 1297 12 94 1330 13 24 1363 13 52 1398 13 79 1434 14 06 10600 1115 11 59 1147 12 00 1178 12 38 1209 12 75 1240 13 10 1271 13 43...

Page 59: ...tional applications 2 See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP 3 kW BHP x 0 838 0 4 0 6 0 8 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 RPM...

Page 60: ...717 2 17 754 2 65 790 3 10 826 3 52 862 3 90 897 4 25 931 4 55 964 4 81 996 5 01 1026 5 15 1054 5 23 1081 5 24 6400 740 2 64 776 3 11 812 3 57 848 3 99 884 4 37 919 4 72 953 5 02 986 5 28 1018 5 48 10...

Page 61: ...5 1129 14 92 1160 15 47 1192 15 98 1223 16 47 1255 16 94 High Static 15 HP Drive Air Flow CFM Available External Static Pressure IWG1 1 Blower performance includes gas heat exchangers and 2 filters Se...

Page 62: ...onal applications 2 See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP 3 kW BHP x 0 838 0 4 0 6 0 8 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 RPM B...

Page 63: ...75 1089 4 76 6000 754 2 35 790 2 79 826 3 21 862 3 61 897 3 97 931 4 29 965 4 58 997 4 81 1028 5 00 1058 5 14 1086 5 21 1112 5 22 6400 779 2 85 814 3 29 850 3 71 886 4 11 921 4 47 955 4 79 989 5 08 10...

Page 64: ...es gas heat exchangers and 2 filters See STATIC RESISTANCE table for additional applications 2 See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous...

Page 65: ...0 11 50 1VP60 BK090 905 950 990 1035 1075 1120 N A 300 25 ZR 7 5 8 63 1VP60 1B5V94 810 850 885 920 960 1000 N A 10 11 50 1VP75X 1B5V110 975 1005 1040 1070 1100 1135 1165 15 17 25 1VP75X 1B5V94 1140 11...

Page 66: ...5 0 HP motor The 7 5 HP motor is required 6 1020 RPM is within the range of the 7 5 HP drives 7 Using the 7 5 HP motor and drive 3 5 turns open will achieve 1020 RPM Example Supply Air Blower Performa...

Page 67: ...Air Size Tons Heat Size Supply Air CFM Cooling Heating Min Max Min Max 180 15 24 4500 7000 4500 7000 32 4500 7000 4500 7000 210 17 5 24 6000 8750 6000 8750 32 6000 8750 6000 8750 240 20 24 6000 9400 6...

Page 68: ...4 1 BK110 BX85 5 1725 0 89 1 15 184T 5 2 6 4 1 1 8 1VP65 8 4 1 BK090 BX81 210 17 5 ZJ ZF 5 1725 0 89 1 15 184T 4 2 5 5 1 1 8 1VP60 10 4 1 3 16 BK110 BX78 7 5 1725 0 91 1 15 213T 4 2 5 5 1 3 8 1VP60 8...

Page 69: ...82 78 75 70 300 25 10000 1 3 1 160 12 5 92 91 91 89 88 88 84 81 76 1 These values have been accessed using a model of sound propagation from a point source into the hemispheric free field The dBA val...

Page 70: ...1 1 7 2 0 0 None 44 3 50 E18 18 0 1 21 7 44 3 50 E36 36 0 2 43 3 63 1 70 E54 54 0 2 65 0 74 0 90 E72 72 0 2 86 6 95 6 110 575 3 60 6 4 40 10 0 0 9 5 9 0 0 None 36 7 40 E18 18 0 1 17 3 36 7 40 E36 36...

Page 71: ...one 141 8 150 E18 13 5 1 37 5 141 8 150 E36 27 0 2 74 9 141 8 150 E54 40 6 2 112 7 175 9 200 E72 54 1 2 150 2 185 2 200 230 3 60 23 0 160 31 5 3 7 26 0 0 0 None 139 3 150 E18 18 0 1 43 3 139 3 150 E36...

Page 72: ...8 110 E18 13 5 1 37 5 104 8 110 E36 27 0 2 74 9 125 4 150 E54 40 6 2 112 7 172 6 175 E72 54 1 2 150 2 181 9 200 230 3 60 16 7 120 26 0 2 1 14 4 10 0 None 103 8 110 E18 18 0 1 43 3 103 8 110 E36 36 0 2...

Page 73: ...9 13 0 5 0 None 77 7 90 E18 18 0 1 21 7 77 7 90 E36 36 0 2 43 3 77 7 90 E54 54 0 2 65 0 87 5 90 E72 72 0 2 86 6 109 1 110 575 3 60 8 7 62 13 5 1 5 10 3 4 0 None 57 7 60 E18 18 0 1 17 3 57 7 60 E36 36...

Page 74: ...0 2 110 E18 13 5 1 37 5 100 2 110 E36 27 0 2 74 9 118 7 125 E54 40 6 2 112 7 165 9 175 E72 54 1 2 150 2 175 2 200 230 3 60 16 7 120 26 0 2 1 20 0 0 0 None 100 2 110 E18 18 0 1 43 3 100 2 110 E36 36 0...

Page 75: ...3 0 0 None 80 5 90 E18 18 0 1 21 7 80 5 90 E36 36 0 2 43 3 80 5 90 E54 54 0 2 65 0 89 1 100 E72 72 0 2 86 6 110 7 125 575 3 60 8 7 62 13 5 1 5 15 4 0 0 None 60 1 70 E18 18 0 1 17 3 60 1 70 E36 36 0 2...

Page 76: ...2 125 E18 13 5 1 37 5 110 2 125 E36 27 0 2 74 9 131 2 150 E54 40 6 2 112 7 178 4 200 E72 54 1 2 150 2 187 7 200 230 3 60 16 7 120 26 0 2 1 20 0 10 0 None 110 2 125 E18 18 0 1 43 3 110 2 125 E36 36 0...

Page 77: ...3 5 0 None 85 5 100 E18 18 0 1 21 7 85 5 100 E36 36 0 2 43 3 85 5 100 E54 54 0 2 65 0 95 3 110 E72 72 0 2 86 6 117 0 125 575 3 60 8 7 62 13 5 1 5 15 4 4 0 None 64 1 70 E18 18 0 1 17 3 64 1 70 E36 36...

Page 78: ...2 13 5 1 5 8 2 0 0 None 51 2 60 E18 18 0 1 17 3 51 2 60 E36 36 0 2 34 6 53 6 60 E54 54 0 2 52 0 62 2 70 E72 72 0 2 69 3 79 5 90 ZJ300 Low Static Drive With Powered Convenience Outlet Size Tons Volt Co...

Page 79: ...60 30 1 225 47 0 3 7 20 0 0 0 None 102 5 125 E18 13 5 1 37 5 102 5 125 E36 27 0 2 74 9 118 7 125 E54 40 6 2 112 7 165 9 175 E72 54 1 2 150 2 175 2 200 230 3 60 30 1 225 47 0 3 7 20 0 0 0 None 102 5 1...

Page 80: ...1 225 47 0 3 7 20 0 10 0 None 112 5 125 E18 13 5 1 37 5 112 5 125 E36 27 0 2 74 9 131 2 150 E54 40 6 2 112 7 178 4 200 E72 54 1 2 150 2 187 7 200 230 3 60 30 1 225 47 0 3 7 20 0 10 0 None 112 5 125 E1...

Page 81: ...0 1 225 47 0 3 7 28 0 0 0 None 109 1 125 E18 13 5 1 37 5 109 1 125 E36 27 0 2 74 9 126 9 150 E54 40 6 2 112 7 174 1 175 E72 54 1 2 150 2 183 4 200 230 3 60 30 1 225 47 0 3 7 26 6 0 0 None 109 1 125 E1...

Page 82: ...1 225 47 0 3 7 28 0 10 0 None 119 1 125 E18 13 5 1 37 5 119 1 125 E36 27 0 2 74 9 139 4 150 E54 40 6 2 112 7 186 6 200 E72 54 1 2 150 2 195 9 200 230 3 60 30 1 225 47 0 3 7 26 6 10 0 None 119 1 125 E1...

Page 83: ...0 23 0 1 5 8 2 0 0 None 47 3 60 E18 18 0 1 17 3 47 3 60 E36 36 0 2 34 6 53 6 60 E54 54 0 2 52 0 62 2 70 E72 72 0 2 69 3 79 5 90 ZR300 Low Static Drive With Powered Convenience Outlet Size Tons Volt Co...

Page 84: ...6 110 E18 13 5 1 37 5 85 6 110 E36 27 0 2 74 9 112 9 125 E54 40 6 2 112 7 160 1 175 E72 54 1 2 150 2 169 4 200 230 3 60 27 2 27 2 203 203 42 5 43 4 3 14 4 0 0 None 84 2 110 E18 18 0 1 43 3 84 2 110 E3...

Page 85: ...2 13 0 0 0 None 62 2 80 E18 18 0 1 21 7 62 2 80 E36 36 0 2 43 3 70 4 80 E54 54 0 2 65 0 81 2 90 E72 72 0 2 86 6 102 9 110 575 3 60 15 1 15 3 135 9 114 23 7 24 1 7 10 3 0 0 None 50 2 60 E18 18 0 1 17 3...

Page 86: ...E18 13 5 1 37 5 95 6 110 E36 27 0 2 74 9 125 4 150 E54 40 6 2 112 7 172 6 175 E72 54 1 2 150 2 181 9 200 230 3 60 27 2 27 2 203 203 42 5 43 4 3 14 4 10 0 None 94 2 110 E18 18 0 1 43 3 94 2 110 E36 36...

Page 87: ...2 2 13 0 5 0 None 67 2 80 E18 18 0 1 21 7 67 2 80 E36 36 0 2 43 3 76 6 80 E54 54 0 2 65 0 87 5 90 E72 72 0 2 86 6 109 1 110 575 3 60 15 1 15 3 135 9 114 23 7 24 1 7 10 3 4 0 None 54 2 70 E18 18 0 1 1...

Page 88: ...18 13 5 1 37 5 90 2 110 E36 27 0 2 74 9 118 7 125 E54 40 6 2 112 7 165 9 175 E72 54 1 2 150 2 175 2 200 230 3 60 27 2 27 2 203 203 42 5 42 5 4 3 20 0 0 0 None 89 8 110 E18 18 0 1 43 3 89 8 110 E36 36...

Page 89: ...2 19 3 0 0 None 68 5 80 E18 18 0 1 21 7 68 5 80 E36 36 0 2 43 3 78 3 80 E54 54 0 2 65 0 89 1 100 E72 72 0 2 86 6 110 7 125 575 3 60 15 1 15 3 135 9 114 23 7 24 1 7 15 4 0 0 None 55 3 70 E18 18 0 1 17...

Page 90: ...18 13 5 1 37 5 100 2 125 E36 27 0 2 74 9 131 2 150 E54 40 6 2 112 7 178 4 200 E72 54 1 2 150 2 187 7 200 230 3 60 27 2 27 2 203 203 42 5 42 5 4 3 20 0 10 0 None 99 8 125 E18 18 0 1 43 3 99 8 125 E36 3...

Page 91: ...2 2 19 3 5 0 None 73 5 90 E18 18 0 1 21 7 73 5 90 E36 36 0 2 43 3 84 5 90 E54 54 0 2 65 0 95 3 110 E72 72 0 2 86 6 117 0 125 575 3 60 15 1 15 3 135 9 114 23 7 24 1 7 15 4 4 0 None 59 3 70 E18 18 0 1 1...

Page 92: ...3 7 24 1 7 8 2 0 0 None 48 1 60 E18 18 0 1 17 3 48 1 60 E36 36 0 2 34 6 53 6 60 E54 54 0 2 52 0 62 2 70 E72 72 0 2 69 3 79 5 90 ZF180 300 Low Static Drive With Powered Convenience Outlet Size Tons Vol...

Page 93: ...4 Second stage heating not required on single stage heating units Jumper is required if there is no Smoke Detector circuit Jumper is required for any combination of R RC or RH 5 5 OCC is an output fr...

Page 94: ...ammable Thermostat 2ET0770010024 includes subbase 2 Terminals A1 and A2 provide a relay output to close the outdoor economizer dampers when the thermostat switches to the set back position 3 TO REMOTE...

Page 95: ...MINALS ON A LIMITED NUMBER OF THERMOSTATS 3 1 2 4 3 1 2 4 Second stage heating not required on single stage heating units Second stage cooling not required on single stage cooling units Jumper is requ...

Page 96: ...8 313 210 17 5 ZJ 2670 2665 85 25 44 477 797 870 520 293 401 580 633 437 320 240 20 ZJ 2702 2697 85 05 44 485 805 878 529 298 406 585 638 443 326 300 25 ZJ 2788 2783 85 25 44 498 833 908 544 306 419 6...

Page 97: ...ood 60 55 Econ Power Exhaust Rain Hood 95 90 Wood Skid 220 220 Roof Curb 190 185 Hot Gas Bypass 10 10 Supply Fan VFD See Supply Fan VFD Weights 1 Weight given is for the maximum heater size available...

Page 98: ...R INTAKE AIR AND POWER EXHAUST RAIN HOODS See detail Y 92 46 5 8 35 1 4 33 2 3 4 3 3 4 B POWER WIRING ENTRY BOTTOM SUPPLY AND RETURN AIR OPENINGS See Note A CONTROL WIRING ENTRY 21 1 2 11 1 8 D GAS SU...

Page 99: ...UST RAIN HOODS See detail Y FIELD SUPPLIED DISCONNECT SWITCH LOCATION BLOWER COMPARTMENT ACCESS Auxiliary DOT PLUG For pressure Drop Reading FRONT VIEW CONTROL BOX ACCESS 21 5 9 3 4 11 1 2 2 3 4 21 1...

Page 100: ...wer exhaust option The covering consists of a heavy black paper composition 3 Replace the side supply and return air compartment panels For side duct applications 1 Replace the side panels on the supp...

Page 101: ...00 Unit Clearances Direction Distance in Direction Distance in Top1 1 Units must be installed outdoors Over hanging structure or shrubs should not obscure condenser air discharge outlet 72 With 36 Max...

Page 102: ...251934 YTG J 0910 102 Johnson Controls Unitary Products Unit Accessory Dimensions ZJ ZR180 300 ZF210 300 Roof Curb ZF180 Roof Curb 25 1 4 14 1 4 115 1 4...

Page 103: ...overall dimension of the ducts allows ductwork penetration between roof joists that are spaced on 72 centers NOTE Ducts can be installed into the curb from the roof All electrical and gas line connec...

Page 104: ...change without notice Printed in U S A 251934 YTG J 0910 Copyright 2010 by Johnson Controls Inc All rights reserved Supersedes 251934 YTG I 1008 Johnson Controls Unitary Products 5005 York Drive Norma...

Reviews: