TECHNICAL GUIDE

SPLIT-SYSTEM HEAT PUMPS

10 SEER – R-22

MODELS:

10 SEER 50 H

Z

 R22

H*RA018S78 THRU H*RA036S78 (1 PH)

(1.5 THRU 3 NOMINAL TONS)

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com

DESCRIPTION

The HRA Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom
matched with one of UPG’s complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
applications to provide a complete system. Electric Heaters
are available if required. Add-On coils are available for use
with upflow, downflow or horizontal furnaces and air handlers.

FEATURES

QUALITY CONDENSER COILS - 

The coil is constructed

of enhanced copper tube and aluminum fins.

COIL PROTECTION -

 Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.

PROTECTED COMPRESSOR - 

The compressor is inter-

nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.

DURABLE FINISH -

 Cabinet is made of pre-painted steel.

The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish  insure
less fading when exposed to sunlight.

LOWER INSTALLED COST - 

Installation time and costs

are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.

TOP DISCHARGE - 

The warm air from the top mounted

fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.

LOW OPERATING SOUND LEVEL - 

The upward air flow

carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and com-
pressor operating sounds.

LOW MAINTENANCE - 

Long life permanently lubricated

motor-bearings need no annual servicing.

EASY SERVICE ACCESS - 

Fully exposed refrigerant con-

nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.

SECURED SERVICE VALVES - 

Secured re-usable ser-

vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.

FACTORY TESTED -

 to verify system operation and con-

trol functioning before shipment.

Summary of Contents for 10 SEER 50HZ R22

Page 1: ...made of pre painted steel The pre treated flat galvanized steel provides a better paint to steel bond which resists corrosion and rust creep Special primer formulas and matted textured finish insure...

Page 2: ...50 1 650 2 350 2 350 Coil Face Area Sq Ft 8 00 8 00 9 15 9 15 Rows Deep 1 1 1 1 Fin Inches 14 14 16 16 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 4 3 4 3 4...

Page 3: ...F entering air temperature 50 RH and rated air flow KW includes compressor outdoor fan and indoor blower motor watts Add on coils include 365 watts 1000 CFM for blower motor COOLING PERFORMANCE MODEL...

Page 4: ...ATION 018S78 036S78 UNIT MODEL dBA 018 76 024 78 030 82 036 82 MINIMUM 18 SERVICE ACCESS CLEARANCE ON ONE SIDE 60 OVERHEAD CLEARANCE 10 CLEARANCE COIL AREA WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO...

Page 5: ...K W 1 55 1 55 1 53 1 71 1 71 1 69 1 68 1 67 1 66 85 T C 17 8 17 2 15 4 18 0 17 5 16 1 18 2 17 8 16 8 S C 10 6 10 7 10 2 11 3 11 7 11 6 12 0 12 8 13 1 K W 1 76 1 74 0 95 1 95 1 93 1 90 1 95 1 93 1 90 9...

Page 6: ...15 2 11 2 08 2 17 2 13 2 10 2 18 2 15 2 12 85 T C 25 4 23 9 21 8 25 7 24 6 22 8 26 1 25 2 23 7 S C 15 3 15 1 14 4 16 4 16 6 16 2 17 4 18 2 18 1 K W 2 31 2 26 1 16 2 33 2 28 2 23 2 36 2 31 2 26 95 T C...

Page 7: ...39 2 35 2 32 2 53 2 49 2 46 2 56 2 53 2 50 85 T C 25 4 23 9 21 8 25 7 24 6 22 8 26 1 25 2 23 7 S C 15 3 15 1 14 4 16 4 16 6 16 2 17 4 18 2 18 1 K W 2 67 2 62 1 40 2 82 2 76 2 71 2 93 2 88 2 83 95 T C...

Page 8: ...39 1 34 7 35 6 39 4 32 5 36 2 S C 23 4 23 5 23 4 24 4 24 8 24 8 25 4 26 1 26 2 K W 3 30 3 25 3 21 3 59 3 54 3 50 3 48 3 43 3 39 85 T C 37 4 34 8 31 9 37 7 34 1 32 6 38 1 33 4 33 4 S C 23 5 24 0 22 2...