279104-YTG-B-0307
6
Unitary Products Group
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric
power input during the same period.
— = Not Applicable.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric
power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - With Air Handler
UNIT
MODEL*
COIL
1
MODEL
ARI HEATING
2
OUTDOOR TEMP
3
47
°
F
17
°
F
HSPF
-3
°
F
7
°
F
17
°
F
27
°
F
37
°
F
47
°
F
57
°
F
MBH COP MBH COP
STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW
E1RA036S(25,4
F2RP/F2FP036 34.0 3.00 20.4
2.16
7.2
15.5 2.40 15.6 2.54 20.4 2.80 24.9 3.03 29.9 3.20 34.0 3.32 38.5 3.50
AHP36,42
34.0 3.00 20.4
2.16
7.2
15.5 2.40 15.6 2.54 20.4 2.80 24.9 3.03 29.9 3.20 34.0 3.32 38.5 3.50
E2RA048S(25,46
F2FP048
37.0 3.08 31.4
2.32
7.5
20.8 3.64 26.1 3.80 31.4 3.97 36.7 4.13 40.1 4.27 47.0 4.47 54.6 4.71
AHP48,60
37.0 3.08 31.4
2.32
7.5
20.8 3.64 26.1 3.80 31.4 3.97 36.7 4.13 40.1 4.27 47.0 4.47 54.6 4.71
E1RA060S(25,46)
F2FP060
58.5 3.12 39.0
2.34
7.6
26.0 4.48 32.5 4.68 39.0 4.88 42.1 4.98 45.1 5.07 58.5 5.49 65.0 5.70
AHP48,60
58.5 3.12 39.0
2.34
7.6
26.0 4.48 32.5 4.68 39.0 4.88 42.1 4.98 45.1 5.07 58.5 5.49 65.0 5.70
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental
electric heat operation.
3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.
HEATING PERFORMANCE - With Furnace Coils
UNIT
MODEL*
COIL
1
MODEL
ARI HEATING
2
OUTDOOR TEMP
3
47
°
F
17
°
F
HSP
F
-3
°
F
7
°
F
17
°
F
27
°
F
37
°
F
47
°
F
57
°
F
MBH COP MBH COP STD MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
E1RA036S25,46
G2FD042(S,H)21
34.0
3.00
20.2
2.14
7.2
11.3
2.40
15.7
2.58
20.2
2.77
24.7
2.94
29.5
3.15
34.0
3.32
40.5
3.50
G1NA036S17L
35.0
3.20
22.0
2.26
7.6
13.3
2.62
17.7
2.74
22.0
2.85
23.3
2.71
24.5
2.57
35.0
3.21
39.3
3.32
G1NA048S21D
35.0
3.20
22.0
2.26
7.6
13.3
2.62
17.7
2.74
22.0
2.85
23.3
2.71
24.5
2.57
35.0
3.21
39.3
3.32
G1UA048S21
34.0
3.00
20.2
2.14
7.2
11.3
2.40
15.7
2.58
20.2
2.77
24.7
2.95
29.5
3.15
34.0
3.32
40.5
3.50
G1FA048S21
34.0
3.00
20.2
2.14
7.2
11.3
2.40
15.7
2.58
20.2
2.77
24.7
2.95
29.5
3.15
34.0
3.32
40.5
3.50
FC/MC/PC35*3X
34.0
3.00
20.2
2.14
7.2
11.3
2.40
15.7
2.58
20.2
2.77
24.7
2.95
29.5
3.15
34.0
3.32
40.5
3.50
FC/MC/PC/UC36*3X
34.0
3.00
20.2
2.14
7.2
11.3
2.40
15.7
2.58
20.2
2.77
24.7
2.95
29.5
3.15
34.0
3.32
40.5
3.50
FC/MC/PC/UC42*3X
34.0
3.00
20.2
2.14
7.2
11.3
2.40
15.7
2.58
20.2
2.77
24.7
2.95
29.5
3.15
34.0
3.32
40.5
3.50
E2RA048S25,46
G2FD048(S,H)21,24
47.0
3.02
31.2
2.32
7.5
21.0
3.56
26.1
3.75
31.2
3.94
36.3
4.13
40.1
4.32
47.0
4.56
54.1
4.59
G1NA048S21D
47.0
2.96
31.2
2.30
7.5
20.7
3.52
25.9
3.75
31.2
3.98
35.2
4.13
39.2
4.29
47.0
4.65
52.3
4.88
G1UA048S21
47.0
3.00
31.2
2.30
7.50
20.9
3.60
26.1
3.79
31.2
3.98
36.3
4.16
42.0
4.39
47.0
4.56
54.0
4.61
G1FA048S21
47.0
3.00
31.2
2.30
7.5
20.9
3.60
26.1
3.79
31.2
3.98
36.3
4.16
42.0
4.39
47.0
4.59
54.0
4.61
FC/MC/PC/UC48C3X
47.0
3.02
31.2
2.32
7.5
21.0
3.56
26.1
3.75
31.2
3.94
36.3
4.13
40.1
4.32
47.0
4.56
54.1
4.59
FC/MC/PC/UC48D3X
47.0
3.02
31.2
2.32
7.5
21.0
3.56
26.1
3.75
31.2
3.94
36.3
4.13
40.1
4.32
47.0
4.56
54.1
4.59
E1RA060S25,46
G2FD060(S,H)24
58.0
3.20
38.5
2.40
7.7
25.5
4.29
32.0
4.50
3.9
4.70
42.1
4.91
45.7
5.11
58.0
5.31
64.5
5.51
G1UA060S24
58.0
3.20
38.5
2.40
7.7
25.5
4.29
32.0
4.50
3.9
4.70
42.1
4.91
45.7
5.11
58.0
5.31
64.5
5.51
G1FA060S24
58.0
3.20
38.5
2.40
7.7
25.5
4.29
32.0
4.50
3.9
4.70
42.1
4.91
45.7
5.11
58.0
5.31
64.5
5.51
FC/MC/PC/UC60C3X
58.0
3.20
38.5
2.40
7.7
25.5
4.29
32.0
4.50
3.9
4.70
42.1
4.91
45.7
5.11
58.0
5.31
64.5
5.51
FC/MC/PC/UC60D3X
58.0
3.20
38.5
2.40
7.7
25.5
4.29
32.0
4.50
3.9
4.70
42.1
4.91
45.7
5.11
58.0
5.31
64.5
5.51
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental elec-
tric heat operation.
3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.