HOW YOUR GAS FURNACE WORKS

Your furnace is a very easy appliance to take for granted. Season after
season, it sits there in your home, keeping you warm and comfortable.
For this reason, you may never have given much thought to the way
your furnace operates. In order to get the safest and most efficient oper-
ation from your furnace, you should understand how your furnace does
its job.

When you set your thermostat to provide more heat in your home, you
are starting the heating cycle of the furnace. First, the inducer motor
starts to purge the heat exchanger of any remaining gases. Next, the
hot surface ignitor glows and after a warm-up period the gas valve
opens and ignition occurs. A short time later, the blower starts and dis-
tributes the warm air throughout the home. When the temperature set-
ting on your thermostat is reached, the gas valve closes, the main
burners are turned off, and the blower continues to run until the remain-
ing warm air in the system is distributed. When the blower stops, the
heating cycle has ended.

START-UP AND SHUTDOWN INSTRUCTIONS

Read the Instructions Below Before Trying to Start the 
Furnace

A.

This appliance does not have a pilot. It is equipped with an ignition
device which automatically lights the burner. Do not try to light the
burner by hand.

B.

BEFORE OPERATING; smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.

C.

Use only your hand to push the gas control switch to the “on” posi-
tion. Never use tools. If the switch will not operate by hand, don’t
try to repair it, call a qualified service technician. Force or
attempted repair may result in a fire or explosion.

D.

Do not use this appliance if any part has been under water. Imme-
diately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control,
which has been under water.

Operating Instructions:

1.

STOP! Read the safety information above.

2.

Set the thermostat to the lowest setting.

3.

Turn off all electric power to the appliance.

4.

Remove burner door.

5.

Move gas control switch to the “OFF” position. Do not force. See
Figure 4.

6.

Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow “B” in the safety information above. If you don’t
smell gas, go to next step.

7.

Move gas control switch to the “ON” position. Do not force. See
Figure 4.

8.

Replace burner door.

9.

Turn on all electric power to the appliance.

10. Set thermostat to the desired setting. Burner will light, which may

take 30-60 seconds.

11.

After three (3) trials for ignition, if the appliance will not operate fol-
low the instructions, “TO TURN OFF THE APPLIANCE” and call
your service technician or gas supplier.

To Turn Off the Appliance:

1.

Set the thermostat to lowest setting.

2.

Turn off all electric power to the appliance if service is to be per-
formed.

3.

Remove burner access panel.

4.

Move gas control switch to the “OFF” position. See Figure 4.

5.

Replace burner access panel.

NOTE: 

The spring-loaded safety cut-off switch, mounted under the

blower deck will automatically cut off the electrical power supply
to the furnace when the blower panel is removed. As a safety
precaution, all electrical power and the gas supply to the furnace
should be turned off before servicing.

If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury, and/or loss of life.

Should overheating occur, or the gas valve fail to shut off,
turn the external manual gas valve in the gas supply line to
the furnace to the “off” position and let the furnace cool off
before shutting off the electrical power supply. Refer to
Figure 5.

 FIGURE 4: Gas Valve - White Rodgers

 FIGURE 5: Gas Piping

R

E

P

L

A

C

E

R

E

P

L

A

C

E

SCRE

W

SCRE

W

INLET

OUTLET

ON / OFF SWITCH

WRENCH
BOSS

PM

C

HI

O
F
F

ON

EXTERNAL MANUAL
SHUTOFF VALVE

TO GAS
SUPPLY

TO GAS
SUPPLY

GROUNDED JOINT UNION
MAY BE INSTALLED
INSIDE OR OUTSIDE UNIT.

DRIP
LEG

Summary of Contents for G8D-UH

Page 1: ...electrical parts that have been wet or the furnace if deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or prop erty damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical s...

Page 2: ...space containing the furnace 4 Examine the furnace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal 5 Examine the furnace casing for obvious signs of deterioration 6 Examine the burner flames to make sure they are in good adjust ment Refer to the pictorial s...

Page 3: ...part of the control system and any gas control which has been under water Operating Instructions 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove burner door 5 Move gas control switch to the OFF position Do not force See Figure 4 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B ...

Page 4: ...ters by using brackets with the number two 2 D If the air filters are on both sides of the furnace then you have a two sided return You must replace both air filters Table 1 will indicate 2 filters by using brackets with the number two 2 3 After you determine the cabinet size and what return configuration you have look up the recommended filter size from Table 1 Removing Filters Internally Mounted...

Page 5: ...en using a 2 Stage thermostat the Timer should be discon nected The Inducer Motor is shifted to high speed by the control closing the contacts of 2LP The High Fire Pressure Switch The Control checks that 2LP is closed The Gas Valve is energized on 2nd Stage High Fire The Control simultaneously de energizes the Heat Low relay and energizes the Heat High relay providing 120 Volts AC to a different s...

Page 6: ...ess doors 2 Remove blower assembly mounting screws and slide the blower assembly out of the slots in the deck If the two shipping screws were not previously removed also remove and discard these two screws located on each front corner of the blower assembly 3 Loosen the blower wheel set screw that secures the blower wheel to the blower motor shaft 4 Remove the motor mount bolts 5 Slide the variabl...

Page 7: ...placement gaskets be avail able before removing vent motor 1 Remove six mounting screws that hold the vent motor to the restrictor plate The surface is gasketed and gasket can be reused if it is carefully removed It is necessary to remove this assembly to gain access to the restrictor plate mounting holes The assembly may be vacuumed if cleaning is necessary If any vent assembly parts are damaged ...

Page 8: ...Dirty Filter Improperly sized duct system Incorrect blower speed selection Incorrect firing rate Faulty blower motor Faulty Control 6 Flash Reason 1LP has opened five times during one call for heat Effect Control enters Soft Lockout It will automatically reset and try again after 1 hour Causes Restricted vent system Vent system that exceeds specifications High wind 7 Flash Reason Flame rectificati...

Page 9: ...OW INDUCER LOW STAGE PRESSURE SWITCH HSI 1ST STAGE MAIN VALVE FLAME SENSE LOW CIRCULATOR HEAT SPEED 1ST STAGE LOW PRESSURE SWITCH CLOSE RECOGNITION HSI WARM UP 17 SEC IGNITION ACTIVATION PERIOD 4 SEC TRIAL FOR IGNITION 7 SEC INTER PURGE 60 SEC HSI WARM UP 27 SEC IGNITION DEACTIVATION PERIOD 3 SEC HEAT FAN DELAY ON 30 SEC BURN TIME POST PURGE 15 SEC HEAT FAN DELAY OFF SELECTABLE 60 90 120 180 SEC O...

Page 10: ...035 19671 001 Rev A 0404 10 Unitary Products Group SECTION III REPLACEMENT PARTS LIST 28 38 39 32 27 3 30 26 5 10 9 22 24 6 20 11 2 37 29 8 23 12 7 35 17 19 21 13 1 16 15 25 4 41 12A 7 35 24 36 12 19 11 ...

Page 11: ...N GAS 20 BRACKET IGNITER 21 DECK BLOWER Rear 22 DECK FRONT 23 HEAT EXCHANGER ASS Y 24 MANIFOLD GAS 25 PANEL ACCESS BURNERS 26 PAN BASE 27 PANEL FRONT Blower 28 PANEL TOP 29 WRAPPER INSULATED 30 CHANNEL TOE PLATE 31 FILTER 32 PLUG WINDOW CLEAR 875 33 RETAINER FILTER 34 CLIP SPRING FILTER RETAINER 35 BRACKET ROLL OUT SWITCH MISCELLANEOUS 36 ORIFICE BURNER Natural 45 37 PLATE RESTRICTOR N Model PLATE...

Page 12: ...stage Heat One Stage Cool ALL MODELS 2TB17700424 THERMOSTAT Subbase for 2TH13700424 ALL MODELS 2ET07700324 THERMOSTAT Programmable ALL MODELS 2ET07700224 THERMOSTAT Deluxe Programmable One stage Heat One stage Cool with subbase ALL MODELS REPLACEMENT PART CONTACT INFORMATION This is a generic parts list To request a complete parts list refer to the contact information below Visit our website at ww...

Page 13: ...035 19671 001 Rev A 0404 Unitary Products Group 13 SECTION IV WIRING DIAGRAM FIGURE 9 Wiring Diagram ...

Page 14: ...035 19671 001 Rev A 0404 14 Unitary Products Group NOTES ...

Page 15: ...035 19671 001 Rev A 0404 Unitary Products Group 15 ...

Page 16: ...applies only to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or servicing 3 Damages resulting from accident abuse fire flood alteration or acts of God tampering altering defacing or removing the product serial number will serve to void this warranty 4 Damages ...

Reviews: