4. Connection
5. Range
3
Installation should be carried out by authorized persons, i.e. having appropriate permissions (min. SEP to 1 kV). The device
is meant to be installed in places protected against adverse weather conditions. The device should be mounted in
accordance with regulations and standards applicable in Poland and in EU. Wires connecting the receiver of electric energy
with power source should be protected against overload and short circuit with protecting devices, which will turn off the
power supply automatically. The device should be powered via a separate line, protected by a fast-acting fuse (e.g. WTS,
S-cl.B), and never by a slow-acting fuse (cl. C or D). Protecting the system with such a fuse can cause loss of warranty
rights. While connecting the device with power supply, you must use wires with suitable gauge. While choosing them, use
tables with long-term load capacity of conductors with direct or alternating current.
230 V AC
phase wire
neutral wire
earth conductor
L
N
brown phase wire
Power supply wire and
antenna mounting method.
230 V / 50 Hz
yellow-green earth conductor
blue neutral wire
The range given by the manufacturer is a variable value, depending on the conditions in the environment in which the device
works. Factors such as building structure, signal interference from other devices, etc. affect range.
230 V / 50 Hz
200 m
30 m
433,92 MHz
L1
open area
L2
indoors
System operation
frequency
20
Remote-controlled roller blind with a motor
L2
L1