YOODA 35 R/S Series Manual Download Page 3

4. Connection

5. Range

3

Installation should be carried out by authorized persons, i.e. having appropriate permissions (min. SEP to 1 kV). The device 

is meant to be installed in places protected against adverse weather conditions. The device should be mounted in 

accordance with regulations and standards applicable in Poland and in EU. Wires connecting the receiver of electric energy 

with power source should be protected against overload and short circuit with protecting devices, which will turn off the 

power supply automatically. The device should be powered via a separate line, protected by a fast-acting fuse (e.g. WTS, 

S-cl.B), and never by a slow-acting fuse (cl. C or D). Protecting the system with such a fuse can cause loss of warranty 

rights. While connecting the device with power supply, you must use wires with suitable gauge. While choosing them, use 

tables with long-term load capacity of conductors with direct or alternating current. 

230 V AC

phase wire

neutral wire

earth conductor

L

N

brown phase wire

Power supply wire and 

antenna mounting method.

230 V / 50 Hz

yellow-green earth conductor
blue neutral wire

The range given by the manufacturer is a variable value, depending on the conditions in the environment in which the device 

works. Factors such as building structure, signal interference from other devices, etc. affect range.

230 V / 50 Hz

200 m

30 m

433,92 MHz

L1

open area

L2

 indoors

System operation 

frequency

20

Remote-controlled roller blind with a motor

L2

L1

Reviews: