background image

E-2. Factory Reset

Factory reset will erase all of your se ngs and restore it to factory defaults. A er the factory reset, 
your device will remain in your Yolink account 

SET Bu on

14

Factory reset will be complete when the status light stops blinking

Hold the SET bu on for 20-25 seconds un l the status light blinks red and green alternately, 
then, release the bu on (

Hold the SET bu on longer than 25 seconds will ABORT the factory 

reset opera on

)

Summary of Contents for YS8005-UC

Page 1: ...Weatherproof Temperature Humidity Sensor YS8005 UC User Guide Rev 1 0 ...

Page 2: ... give us a chance to assist you before returning your purchase We at Customer Support are here for you If you need any assistance installing se ng up or using a YoLink product or our app Find addi onal support and ways to reach us at www yosmart com support and service Or scan this QR code with your smartphone Email us 24 7 at service yosmart com Call us 9AM to 5PM Pacific Standard Time at 949 825 ...

Page 3: ...F G H I In the Box 1 Introduc on 2 Set Up 4 Using the YoLink App 7 Maintenance 13 Specifica ons 17 Troubleshoo ng 19 Warning 20 Customer Service Warranty 22 Revised 04 08 2021 Copyright 2021 YoSmart Inc All rights reserved ...

Page 4: ...A In the Box 1 A Weatherproof Temperature Humidity Sensor B Quick Start Guide B A ...

Page 5: ...u can set high and low levels alerts for temperature and humidity When an alert level is reached the LED will blink red once and no fica ons will be sent to you via the YoLink app Available no fica on types are email and banner push no fica ons on your Apple or Android smartphone each configurable in app se ngs 2 Openings Used for temperature and humidity sensing SET Bu on Status LED Hanging Loop Ring...

Page 6: ...evice turned on Blinking Green Connec ng to Cloud Slow Blinking Green Upda ng Blinking Red Once Device alerts or device is connected to the cloud and is func oning normally Fast Red Every 30 Seconds Blinking Ba eries are low please replace the ba eries see page 15 Blinking Red And Green Alternately Restoring to Factory Defaults ...

Page 7: ...thernet patch cable included to your network router switch etc recommended Otherwise connect your Hub to your home 2 4 GHz Wi Fi network only when necessary Refer to the Hub set up manual for more informa on 1 Make sure your Hub is connected to the internet green LED indicator is blinking blue LED indicator is always on Download the YoLink app through Apple App Store or Google Play Store Search in...

Page 8: ...use 2 1 You will need to press the SET bu on once again if the device failed to connect to the cloud 2 Pressing the SET bu on at any other me a er this ini al process will result in the LED blinking red once only This indicates the device is connected to the cloud and is func oning normally 3 If the red LED does NOT blink as noted this may indicate a problem with the sensor Please see the troubles...

Page 9: ...knocked down 1 The sensor must NOT be submerged 2 For accurate readings do not obstruct the openings on the sensor 3 Do not place the sensor on or near sources of extreme heat or cold 4 While this device is designed for outdoor use refer to the environment opera ng range informa on on page 17 Use of this device for applica ons outside of the environmental opera ng range is likely to damage the sen...

Page 10: ...ls page refer to page 9 Latest Refresh me for Temperature Humidity Value Sensor refresh frequency refer to page 8 Device Alert History Historical log of temperature and humidity alerts logged with date me Latest Refresh Temperature Value Humidity Value Blue Normal Red Warning Chart for History Value of temperature and humidity Hourly last twenty four hours Daily last seven days Download the histor...

Page 11: ...wise the values will be refreshed automa cally once an hour a The SET bu on has been pressed b At least 0 9 F 0 5 C change over a period longer than 1 minute d At least 10 change over a period longer than 1 minute c At least 3 6 F 2 C change within 1 minute e Device alert level reached or restored to normal range SET Bu on ...

Page 12: ...ure and humidity alerts logged with date me j Device Model k Device EUI unique l Device SN unique m Connec on Status of sensor and Hub n Current Ba ery Level Shown red if ba ery level is low o Firmware Version ready now refer to page 13 indicates a new update is available p Remove Device From Current Account Tap to delete the device from your YoLink account A er changing Alert and or Calibra on se...

Page 13: ...humidity value low alert value or above the high alert value set below Slide to set the low temperature alert value Default is 64 F 18 C b c Slide to set the High temperature alert value Default is 95 F 35 C d Slide to set the low humidity alert value Default is 0 e Slide to set the high humidity alert value Default is 100 f Enable or disable re no fica on a er a temperature or humidity alert g Set...

Page 14: ... b 1 Edit name b 2 Edit trigger b 3 Edit behavior You must have at least one ac on device or you cannot set a behavior b 4 Edit when Set a me range for the automa on always or during specific days or mes b 5 Tap to save the se ngs c 1 Tap bu on to enable or disable the automa on 2 Swipe le to view the history logs and to edit or delete the automa on c Click to edit the automa on Swipe Le a b 1 b 2 ...

Page 15: ... on guide Tap in the upper le corner to go to My Profile Connect YoLink with Alexa to monitor the status of your devices through voice commands YoLink Humidity Sensor is integrated Weatherproof Temperature with Alexa and is also integrated with IFTTT com works as a trigger device using IFTTT 12 ...

Page 16: ...rs maximum To force an immediate update press the SET bu on on the device twice to make the device enter update mode In Firmware if a new version is listed as available ready now click it to start the firmware update process You may use your device during the update as it is performed in the background The LED light will slowly blink green during the update and the process will be complete within 2...

Page 17: ...your device will remain in your Yolink account SET Bu on 14 Factory reset will be complete when the status light stops blinking Hold the SET bu on for 20 25 seconds un l the status light blinks red and green alternately then release the bu on Hold the SET bu on longer than 25 seconds will ABORT the factory reset opera on ...

Page 18: ...ry replacement instruc ons closely 2 Do not mix old and new ba eries 3 Make sure that the bo om shell and sealed rubber pads are ghtly secured Otherwise the entry of water into the sensor may cause severe damage Use tweezers to take out the four s e a l e d r u b b e r pads at the base of the device 1 Use a screwdriver to u n s c rew t h e screws at the base of the device and remove the base 2 15 ...

Page 19: ...Remove the two old ba eries 3 Install new two AAA ba eries 4 Close and secure t h e b a s e b y reinstalling and g hte n i n g t h e four screws 5 Rea ach the four sealing rubber pads 6 16 2 x AAA ...

Page 20: ...ithium non rechargeable Humidity Value Accuracy 0 1 Alert Temperature 22 F 158 F 30 C 70 C Alert Humidity 0 100 135mA opera ng 35uA standby Device Current Draw Sensor Types Temperature Humidity 17 IP Ra ng IP67 Dimensions 2 44 x 2 44 x 0 87 inches 62 x 62 x 22 millimeters L x W x D ...

Page 21: ...9 41 F 140 F F 5 C 60 C 0 4 C 0 72 140 F 176 F F 60 C 80 C 0 75 C 1 35 Environment Working Temperature 22 F 158 F 30 C 70 C Working Humidity 95 non condensing Temperature Error Typical 40 14 40 10 F F 1 44 F C C 0 8 C 14 F 41 F F 10 C 5 C 0 4 C 0 72 41 F 140 F F 5 C 60 C 0 2 C 0 36 140 F 176 F F 60 C 80 C 0 4 C 0 72 Humidity Error Typical 77 F 25 C 0 20 80 100 3 5 20 80 2 ...

Page 22: ...press the SET bu on on the Weatherproof Temperature Humidity sensor once If sensor is out of range with Hub reloca ng the sensor or Hub may be required For a device with low ba ery indicators or alerts or if the condi on of the ba eries is in ques on replace the ba eries with two premium AAA lithium ba eries 2 Receive no fica ons out of the alert range Alert se ngs are not saved Refer to Details pa...

Page 23: ... Temperature Humidity Sensor only as outlined in this manual Improper use may damage the unit and or void the warranty Do not obstruct the opening on the housing Do not install or use this device outside of the temperature and humidity range listed in the Environmental sec on in Specifica ons on page 18 Do not install or use this device where it will be subjected to high temperatures and or open fla...

Page 24: ...all or use this device where it will be subjected to physical impacts and or strong vibra on Physical damage is not covered by the warranty Please contact Customer Service before a emp ng to repair disassemble or modify the device any of which can void the warranty and permanently damage the device 21 Install or use this device only in clean environments Extremely dusty or dirty environments may p...

Page 25: ...ir or replacement of the Weatherproof Temperature Humidity sensor only at YoSmart s sole discre on YoSmart will NOT be liable for the cost of installing removing nor reinstalling this product nor direct indirect or consequen al damages to persons or property resul ng from the use of this product This warranty only covers the cost of replacement parts or replacement units it does not cover shipping...

Page 26: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures FCC Statement Reorient or relocate the receiving antenna Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Increase the separa on between the equipment and receiver Consult the dealer or an experienced radio ...

Page 27: ...applicable to only Mobile Configura ons The antennas used for this transmi er must be installed to provide a separa on distance of at least 20 cm from all persons and must not be co located or opera ng in conjunc on with any other antenna or transmi er FCC RF Radia on Exposure Statement Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifica ons to t...

Reviews: