Yolco GX37 User Manual Download Page 6

7. 

 

Cleaning and maintenance

• Turn off the device and disconnect it from the external power supply before each cleaning.

• The device must not be cleaned under running water.

• Do not use aggressive cleaning agents for cleaning.

• Clean the outside and inside of the device with a damp cloth without the control panel, power section, modular battery socket or ventilation openings.
All sections mentioned above clean with dry and soft cloth.

 Manual defrosting
During long-term operation of the device, a layer of frost may appear inside it. This can reduce its performance. To defrost the device, disconnect it from the power supply, 
empty the cooling compartment and leave the lid open. After frost has condensed, wipe off the remaining water with a soft cloth or pout excess water out.

8.

 Troubleshooting the most

    

common faults

Foodstuffs have been frozen:
• Change the cooling temperature to higher, the set temperature is too low.

The device makes a sound of flowing liquid:
• This sound is normal.

Droplets of liquid appear around the fridge door:
• Liquid droplets appear due to the temperature difference between the device and its surroundings, and are normal.

When starting the device, the compressor makes a loud noise:
• It is normal for the compressor to work loudly at start-up
 
 The device does not work:
• Check if the device has been switched on with the button       .
• Check that the device is correctly connected to the power source.
• Check whether the power supply is functional.
• Check if the fuse has blown.

The device displays the F1 code:
• Code informing about 12 / 24V supply voltage drop. Change the protection setting to lower from H (high) to M (medium) or from M (medium) to L (low).

The device displays the F2 code:
• Code informing about fan overload. Switch the device off and on again after 30 minutes.

The device displays the F3 code:
• Code informing about activation of protection against too frequent compressor operation. Switch the device off and on again after 30 minutes.

The device displays the F4 code:
• Code informing about compressor overload. Switch the device off and on again after 30 minutes.

The device displays the F5 code:
• Code informing about compressor module overheating. Switch the device off and on again after 30 minutes.

The device displays the code F6 or F7:
• Code informing about temperature sensor error. Please contact the seller.

1

2

3

4

FUSE

FUSE

15 A

102mV

4.8 mΩ

340 A²s

Fuse specification

Current Rating

Voltage Drop

Cold Resistance

I2t

 Fuse replacement 

1. Untwist and remove the red ring from the plug 
2. Remove the screw and remove the housing 
3. Remove the tip of the plug 
4. Remove the fuse and replace it with a new one
with identical parameters 
5. Insert the plug tip 
6. Put the housing on and fix it with the screw 

 (CAUTION! Before screwing the housing, make sure
that the hole of the power cord contact is overlapped
with the hole in the plug housing).

7. Put the red ring and twist to secure it on the plug.

Summary of Contents for GX37

Page 1: ...indeed www yolco pl USER MANUAL PORTABLE COMPRESSOR REFRIGERATOR GX37 Instrukcja obs ugi dost pna r wnie na User manual also available at Bedienungsanleitung erh ltlich auch bei...

Page 2: ...ments Farm houses and by clients in hotels motels and other residential type environments Bed and breakfast type environments Catering and similar non retail applications This refrigeration appliance...

Page 3: ...V 12 4V 24 3V 25 7V 3 Description of operation and basic function The tourist fridge is used to cool food Thanks to high class insulation and an e cient compressor the cooling process is extremely fas...

Page 4: ...e on o button Settings button Temperature increase button Temperature reduction button Current temperature inside the deivice Temperature scale C F Battery protection mode H M L Battery charge indicat...

Page 5: ...tion Disconnecting the Bluetooth connection Setting the max temperature Setting the min temperature Setting the compressor start delay after starting the device in minutes Chamber hysteresis setting t...

Page 6: ...that the device is correctly connected to the power source Check whether the power supply is functional Check if the fuse has blown The device displays the F1 code Code informing about 12 24V supply...

Page 7: ...e in the equipment of dangerous substances mixtures and components Manufacturer Foshan Shunde Guanyuda Power Supply Co LTD Commercial registration number 9144060676734487XX Adress XiChongindustrial Ar...

Reviews: