background image

EN
Recommended

1.     Branch pipe

2.     Main pipe approx. 1:100 Downward pitch away from the compressor

3.     Drain trap

4.     Shut-off valve

5.     Filter

6.     Regulator

7.     Oiler

8.     Coupling

9.     Air Hose (thick as poss)

10.   Air compressor

11.   Main pipe

 

Technical specifications

Brand

:  Toku

Safety standard

: EN ISO 11148-7

Wheel size (mm)

:  45

RPM

:  18000

Power (kW)

:  0,28

Collet chuck (mm)

:  6

Airconsumption (l/s)

:  8,0

Weight (kg)

:  0,55

Airconnection

:  PT 1/4"

Hosediameter (mm)

:  10

Vibration level (m/s²)

:  1,3

Sound level (dB(A))

:  77

mm A

:  162

mm B

:  43

mm C

:  19

mm D

:  46

mm E

:  48

Maximum Airpressure (Bar)

:  6,3

Before taking into use

Read and understand the contents of this manual before installing, operating, repairing, maintaining, changing accessories of this tool.

Only qualified and trained operators should install, adjust or use the tool.

Please fill some droplets of resin and acid free oil into the air inlet and let the tool run free for a couple of seconds. (E.g. Red Rooster
air tool oil: Order no. Atlub)

Before connecting the hose to the tool please check, whether the hose and the quick coupler are clean. Do this by letting air run freely
through hose and quick coupler, It is absolutely necessary, that quick coupler and hose have a sufficient diameter. Please note, that
the hose is never too big, but mostly too small!

Air pressure at the inlet of the tool during running has to be at the maximum of 6.3 bar. When this pressure is exceeded, unnecessary
wear and/or damage will occur. At the pressure of below 5.5 bar power loss will occur and if the pressure is excessively low, also
additional wear/damage will occur.

The quality of the compressed air must be good, which means clean, dry and this is best assured by means of an air filter. We advise
the use of a complete FRL (filter, regulator, lubricator) unit. The oiler has to be adjusted to approx. 3 to 6 droplets per minute. The air
hose between oiler and tool should never exceed a length of 6 to 8 meters.

In those cases, where it is possible, use of a centralized oiler is recommended by us. This system will allow use of less oil and assure a
perfect lubrication. When using a centralized oiler, oil consumption can be reduced by up to 80%.

If you intend not to use the tool for a longer period of time, it has to be oiled. Please fill some droplets of resin and acid free oil into the
air inlet and let the tool run free for a couple of seconds. 

Do not ignore safety precautions!

Safety

Do not modify this tool in any way, this can cause danger for the operator.

Make sure that this manual is accessible at all times for any relevant person, in case of loss of this manual ask your dealer for a new
copy or refer to our website.

Risk of explosion or fire: Make sure that generated sparks and/or increased temperature of the work piece can not cause any
explosion or ignite a fire.

Make sure that during operation of the tool no projectiles can be generated, this can be dangerous and may cause injuries.

Make sure that the work piece is securely fixed.

Make sure that the inserted tool or accessory is mounted correctly, if not it may cause high speed projectiles.

Summary of Contents for TOKU MG-1B

Page 1: ... MG 1B MANUAL EN www rami yokota com ...

Page 2: ......

Page 3: ...At the pressure of below 5 5 bar power loss will occur and if the pressure is excessively low also additional wear damage will occur The quality of the compressed air must be good which means clean dry and this is best assured by means of an air filter We advise the use of a complete FRL filter regulator lubricator unit The oiler has to be adjusted to approx 3 to 6 droplets per minute The air hose...

Page 4: ...ction systems should be useded if possible and be maintained according manuafacturer s instructions Wear the appropriate clothing to feel comfortable at the workplace Cold exhaust air should be diverted from hands and body Air under pressure can cause injuries be aware of this Never direct the exhaust air to yourself or anyone else Do not use quick change couplings direct on the air inlet of the t...

Page 5: ...r is working properly a damaged silencer has to be replaced In case of disposal of the tool follow local regulations so as much as possible can be recycled Do not throw it in the normal waste bin Intended use The user or the user s employer shall assess the specific use that can be present as a result of each use Never use the tool otherwise than the tool is designed for and as explained in this m...

Page 6: ...E RAMIYOKOTA B V hereby declare that this product is conform the European Directive 2006 42 EG and the standard EN ISO 11148 7 Technical file available from Rami Yokota BV RAMIYOKOTA BV De Ruyterkade 120 1011 AB Amsterdam THE NETHERLANDS Date 09 03 2020 Place Amsterdam Signature N Nauta Managing Director RAMIYOKOTA BV ...

Page 7: ... www rami yokota com ...

Reviews: