background image

EN
Recommended

1.     Branch pipe

2.     Main pipe approx. 1:100 Downward pitch away from the compressor

3.     Drain trap

4.     Shut-off valve

5.     Filter

6.     Regulator

7.     Oiler

8.     Coupling

9.     Air Hose (thick as poss)

10.   Air compressor

11.   Main pipe

 

Technical specifications

Brand

:  Yokota

Safety standard

:  EN ISO 11148-6

Power Supply (V)

:  AC 100 ~ 240V, 50/60 Hz

mm H

: 70

mm W

: 215

mm D

: 300

Before taking into use

Read and understand the contents of this manual before installing, operating, repairing, maintaining, changing accessories of this tool.

Only qualified and trained operators should install, adjust or use the tool.

Please fill some droplets of resin and acid free oil into the air inlet and let the tool run free for a couple of seconds. (E.g. Red Rooster
air tool oil: Order no. Atlub)

Before connecting the hose to the tool please check, whether the hose and the quick coupler are clean. Do this by letting air run freely
through hose and quick coupler, It is absolutely necessary, that quick coupler and hose have a sufficient diameter. Please note, that
the hose is never too big, but mostly too small!

Air pressure at the inlet of the tool during running has to be at the maximum of 6.3 bar. When this pressure is exceeded, unnecessary
wear and/or damage will occur. At the pressure of below 5.5 bar power loss will occur and if the pressure is excessively low, also
additional wear/damage will occur.

The quality of the compressed air must be good, which means clean, dry and this is best assured by means of an air filter. We advise
the use of a complete FRL (filter, regulator, lubricator) unit. The oiler has to be adjusted to approx. 3 to 6 droplets per minute. The air
hose between oiler and tool should never exceed a length of 6 to 8 meters.

In those cases, where it is possible, use of a centralized oiler is recommended by us. This system will allow use of less oil and assure a
perfect lubrication. When using a centralized oiler, oil consumption can be reduced by up to 80%.

If you intend not to use the tool for a longer period of time, it has to be oiled. Please fill some droplets of resin and acid free oil into the
air inlet and let the tool run free for a couple of seconds. 

Do not ignore safety precautions!

Safety

Do not modify this tool in any way, this can cause danger for the operator.

Make sure that this manual is accessible at all times for any relevant person, in case of loss of this manual ask your dealer for a new
copy or refer to our website.

Make sure that during operation of the tool no projectiles can be generated, this can be dangerous and may cause injuries.

Make sure that the work piece is securely fixed.

Make sure that the inserted tool or accessory is mounted correctly, if not it may cause high speed projectiles.

Make sure that no dangerous circumstances can occur for other persons in the work area.

Always wear safety glasses during operation of the tool. The grade of protection must be in relation to the risk of the operation.

Rotating mounted accessories can be easily entangled by rubber coated or metal reinforced gloves. Wear suitable gloves.

Keep fingers out of reach of the inserted tool or accessory.

Never hold the drive shaft, socket, bit, inserted/mounted tool/accessory with your hands while rotating.

For impact and impulse wrenches: Only use impact sockets, see our Action catalogue.

The use of safety-/working gloves is recommended.

Use ear protection as instructed by your employer or as required by occupational health and safety requirements.

Reasonable countermeasures have to be taken to keep the noise level as low as possible.

Disconnect the air supply before changing inserted tools, accessories, repairs or when the tool is not being used.

Always check that the mounted tool or accessory is not damaged. Breakage and flying fragments can cause injuries.

Summary of Contents for E-PDA-4

Page 1: ... E PDA 4 MANUAL EN www rami yokota com ...

Page 2: ......

Page 3: ...ended by us This system will allow use of less oil and assure a perfect lubrication When using a centralized oiler oil consumption can be reduced by up to 80 If you intend not to use the tool for a longer period of time it has to be oiled Please fill some droplets of resin and acid free oil into the air inlet and let the tool run free for a couple of seconds Do not ignore safety precautions Safety...

Page 4: ...ever use a damaged tool Tools shall be inspected periodically to verify that the ratings and markings required by the applicable part of the ISO 11148 series are legibly marked on the tool If not the user employer shall obtain replacement labels from the dealer or manufacturer Use only tight fitting gloves loose gloves can be trapped or entangled causing injuries Use the specified gloves for the a...

Page 5: ...in the normal waste bin The tool should be maintained regularly to minimize the noise emission and occurring vibration Disconnect the air supply during maintenance on the tool Intended use The user or the user s employer shall assess the specific use that can be present as a result of each use Never use the tool otherwise than the tool is designed for and as explained in this manual Damages as a c...

Page 6: ...Technical file available from Rami Yokota BV RAMIYOKOTA BV De Ruyterkade 120 1011 AB Amsterdam THE NETHERLANDS Date 09 03 2020 Place Amsterdam Signature N Nauta Managing Director RAMIYOKOTA BV ...

Page 7: ... www rami yokota com ...

Reviews: