YOKOGAWA vigilantplant YTA70 User Manual Download Page 4

P. 4

IM01C50C03-02EN

YTA70 HART 7 DD Menu Tree

Device setup

PV

Loop current

PV LRV

PV URV

Process 

variables

Dynamic 

variables

Diag/Service

Basic setup

Detailed 

setup

Review

Sensor

El/CJC 

Dev var 

status

Time stamp

Sensor data quality

Sensor limit status

El/CJC data quality

El/CJC limit status

PV

PV % rnge

Loop current

SV

TV

QV

Dyn var status

Dyn var assign

Time stamp

Status

Loop test

Calibration

Simulate

Dev var 

logging

Trend

Master reset

Tag

Long Tag

Range values

Sensor config

Sensor s/n

Sensors

Signal 

condition

Output 

condition

Device 

information

Sensor errors

ADC errors

Misc. errors

Cfg chng count

Reset cfg chng flag

Ext device status

Apply values

D/A trim

Override D/A trim

Enable dev var simultation

Disable dev var simultation

Read dev var max/min log

Reset dev var max/min log

Num trends support

Current date

Current time

Control

Dev var code

Sample interval

Date latest result

Time latest result

Result

Range configuration

PV unit

PV LRV

PV URV

PV LSL

PV USL

PV min span

Snsr config

Snsr type

Snsr wire

Snsr unit

Snsr damping

Process 

sensor

El/CJC

Error 

detection

PV % rnge

PV LRV

PV URV

Apply values

PV LSL

PV USL

PV min span

Analog output

HART output

Manufacturer

Tag

Long Tag

Descriptor

Message

Date

Write protect

Write enable

New 

password

Revision 

numbers

Max dev vars

Device profile

Snsr value

Snsr limit status

Snsr data quality

Snsr probe break detect

Snsr config

Snsr input trim

Snsr info.

El/CJC

El/CJC limit status

El/CJC data Quality

El/CJC probe break detect

El/CJC config

El/CJC trim

El/CJC Info.

No test performed

broken sensor

shorted sensor

broken and shorted sensor

Loop current

Loop current 

0%

Loop current 

100%

Loop current 

lower limit

Loop current 

upper limit

Set limit = 

NAMUR

Loop test

D/A trim

Override D/A 

trim

Broken sensor

Shorted 

sensor

Broken snsr value

NAMUR down

NAMUR up

Poll addr

Loop current 

mode

Num req 

preams

Num resp 

preams

Set real-rime 

clock

Dyn var 

assignment

Burst 

condition

Event 

notification

Total burst msgs

Burst message 1

Burst message 2

Burst message 3

Num events 

support

Event notif control

Event mask

Event notif retry 

time

Max update time

Event debounce 

interval

Knowledge

Burst mode

Burst command

Burst dev var

Burst trigger 

mode

Burst trigger 

level

Burst units

Update period

Max update 

period

Classification

Event status

Time first unack 

event triggered

Universal rev

Fld dev rev

Software rev

Hardware rev

Final asmbly 

num

Dev id

Dev ser nr

Chng 

universal rev

Shorted sensor value

NAMUR down

NAMUR up

F11E.ai

YTA70 HART 5 DD Menu Tree

1.Device 

        setup

2.PV 

3.Electr

4.Snsr1

5.PV AO

6.PV %rnge

1.Process 

   Variable

2.Diag/

    Service

 

3.Basic 

      Setup

4.Detailed 

      Setup

5.Review

1.PV

2.Electr

3.Snsr1

4.PV AO

5.PV % rnge

1.PV LRV

2.PV URV

3.PV unit

4.LSL

5.USL

1.PV

2.Snsr1 

3.PV unit

4.Sensor setup

5.Sensor info

1.PV AO

2.Output rnge

3.Sensor error 

              values

4.Loop test

5.Scaled 

            D/A trim

6.D/A trim

7.Override 

            D/A trim

1.Poll addr

2.Num req preams

3.Num resp preams

1.Process 

            sensor

2.Electr

1.Sensor config

2.Error detection

3.Cable 

         resistance

4.Snsr s/n

1.Broken sensor

2.Shorted sensor

1.Sensor errors

2.ADC errors

3.Misc. errors

1.Range values

2.D/A trim

3.Scaled 

          D/A trim

4.Override 

          D/A trim

1.Write protect

2.New password

1.Analog 

            output

2.HART 

           output

1.Status

2.Loop test

3.Calibration

4.Write 

 Protection

5.Read 

  max/min log

6.Reset 

 max/min

Online Menu

(Device setup) (Process Variables)

(Diag/Service)

1.Tag

2.Range 

           values

3.Sensor 

            config

4.PV Damp

5.Snsr s/n

(Basic Setup)

1.Sensors

2.Signal 

 condition

3.Output 

 condition

4.Device

   information

(Detailed setup)

(Status)

(Calibration)

(Range values)

1.PV LRV

2.PV URV

3.PV unit

4.LSL

5.USL

(Range values)

(Sensors)

1.PV LRV

2.PV URV

3.PV unit

4.PV % rnge

5.PV Damp

(Signal condition)

(Process sensor)

(Output condition)

(HART output)

(Analog output)

1.USL

2.LSL

3.Min span

1.AO 0%

2.AO 100%

3.AO lo lim

4.AO up lim

(Output range)

(Sensor error values)

(Sensor setup)

1.Enter value

2.Measure value

(Cable resistance)

1.Br(Sh) sensor

2.NAMUR down

3.NAMUR up

(Broken/shorted 

                   sensor)

F12E.ai

Device Variables Mapping (HART 7)

There are two device variables available.

 

1)   Sensor
2)   Electronics/CJC (El/CJC)

PV

SV

TV

QV

Mapping

Sensor

Electronics/CJC

F13E.ai

Burst Parameters (HART 7)

Command 

Parameter

Burst Command 

Burst Msg 

Trigger Mode

Burst Trigger 

Source

Burst Trigger 

Units

PV 
Temperature value 
assigned to PV

Cmd1: PV

Continuous

-

-

Window

PV

Depend on PV 
assignment

Rising

Falling

On-change

% range/Loop 
current

Cmd2: % range/
Current

Continuous

-

-

Window

% range

%

Rising

Falling

On-change

Process variables/
Loop current

Cmd3: Dyanamic 
variables/Current

Continuous

-

-

Window

PV

Depend on PV 
assignment

Rising

Falling

On-change

Process vars/% 
range/Loop current 
with status

Cmd9: Device 
variables with status

Continuous

-

-

Window

Sensor, El/CJC, 
PV, SV, TV, 
QV(*1)

Depend on 
burst trigger 
source

Rising

Falling

On-change

Process vars/% 
range/Loop Current

Cmd33: Device 
variables

Continuous

-

-

Window

Sensor, El/CJC, 
PV, SV, TV, 
QV(*1)

Depend on 
burst trigger 
source

Rising

Falling

On-change

Self diagnosis 
information

Cmd48: Additional 
device status

Continuous

-

-

(*1) Loop current and % range are selectable from menu but not available.

8.3 Parameters

YTA70 HART 7 DTM Menu Tree

F10E.ai

PV

PV % rnge

Loop current

SV

TV

QV

Dyn var status

Dyn var assign

Time stamp

Apply values

D/A trim

Clear D/A trim

Event status

First unack evt tgr

Device Configuration

Diagnostics

Process Variable

Basic setup

Detailed setup

Review

Configure/Setup

Tag

Long Tag

Range values

Sensor setup

Snsr s/n

Range configuration

PV unit

PV LRV

PV URV

PV LSL

PV USL

PV min span

Snsr config

Snsr type

Snsr wire

Snsr unit

Snsr cable resist

Snsr damping

Snsr error detection

Broken sensor

Shorted sensor

Sensors

Signal condition

Output condition

Device information

Process sensor

El/CJC

Snsr error detection

Snsr config

Snsr type

Snsr wire

Snsr unit

Snsr cable resist

Cable resist measurement

Snsr damping

Snsr trim

Snsr trim reset

Snsr zero trim

Snsr L trim

Snsr U trim

Snsr trim support

Snsr min L trim

Snsr max L trim

Snsr min U trim

Snsr max U trim

Snsr min diff trim

Snsr s/n

Snsr LSL

Snsr USL

Snsr probe conn

Snsr temp standard

Snsr min span

Snsr

Snsr limit status

Snsr data quality

Snsr probe break detect

Sensor setup

Snsr input trim

Snsr info.

Status

Loop test

Calibration

Simulate

Dev var logging

Trend

Num trends support

Current date

Current time

Control

Dev var code

Sample interval

Date latest result

Time latest result

Result

Device reset

Process variables

Dynamic variables

Process Variables

El/CJC

El/CJC limit status

El/CJC data Quality

El/CJC probe break detect

El/CJC config

El/CJC trim

El/CJC info

PV % rnge

PV LRV

PV URV

Apply values

PV LSL

PV USL

PV min span

Analog output

HART output

Loop current

Loop cur 0%

Loop cur 100%

Loop cur lower limit

Loop cur upper limit

Set limit = NAMUR

Loop test

D/A trim

Clear D/A trim

Broken sensor

Shorted sensor

Broken snsr value

NAMUR down

NAMUR up

Shorted snsr value

NAMUR down

NAMUR up

Poll addr

Loop current mode

Num req preams

Num resp preams

Set real-time clock

Dyn var assignment

Burst condition

Event notification

Total burst msgs

Burst message 1

Burst message 2

Burst message 3

Burst mode

Burst command

Burst dev var

Burst trigger mode

Burst trigger level

Burst units

Update period

Max update period

Classification

Num events support

Notif control

Event mask

Retry time

Max update time

Debounce interval

Knowledge

Manufacturer

Tag

Long Tag

Descriptor

Message

Date

Write protect (Write enable)

New password

Revision numbers

Max dev vars

Device profile

Universal rev

Fld dev rev

Software rev

Hardware rev

Final asmbly num

Dev id

Dev ser nr

Chng universal rev

Device Diagnostics

Sensor errors

ADC errors

Misc. errors

Cfg chng count

Reset cfg chng flag

Ext device status

Read dev var max/min log

Reset dev var max/min log

Diag/Service

Snsr

El/CJC 

Dev var status

Time stamp

Reviews: