<3. Installation>
3-7
IM 12K01B02-01E
3.4.4
Connecting Detector to Converter
• Run the cable connectors of detector through the cable clamps at the lower left of converter
case.
• Connect the connectors of the detector to CN1 and CN2 at the lower left of converter case.
• Securely fasten the round terminal of shield line, with a screw (M3), to the screw hole under
the connections CN1 and CN2.
CN1
2-pin connector
CN2
4-pin connector
Securely fasten the round terminal of shield line, with a screw (M3).
Detector cables
Converter
3.4.5
Connecting Float Switch Cable of Overflow Tank to
Converter
• Run the float switch cables of the overflow tank through the cable clamps at the lower left of
converter case.
• Connect the cables to the terminals No.7 and 8 at the lower center of converter inside.