Manual Change for IM 01G05B02-01E 1st Edition : No.15-021-E Nov. 24 2015-00
This is the supplement for the original manual (No. IM 01G05B02-01E, 1st Edition) regarding the added and changed
items as below. Please also refer to this supplement when you read the manual.
Addition to the chapter
“2. Handling Precautions” (page 7) :
Attention!
The instrument must not be used in a corrosive atmosphere.
Changes to the section
“2.1 Scope of Delivery” (page 7) and the section “3.4.2 Rear Panel” (page 13):
Change the figure of a nameplate to as below.
Addition to the section
“2.3 General Precautions” (page 8) :
・
The power supply adapter and the AC cable are dedicated to US300PM. Please do not use them with other
devices.
・
Do not disassemble or remodel.
Addition to the chapter “4. Getting Started” (page 15) :
Attention!
The current outputs may temporarily turn unstable during the switch-on sequence and
parameter display / setting mode. Take care of your process not to be affected by this
behavior.
User’s
Manual
US300PM
Ultrasonic Flowmeter
Manual Change
No. 15-021-E