background image

IM 05F01D02-03E (1)

This manual contains a parameter map as a guideline for setting parameters, and lists of parameters for recording User
Settings.

Contents

1. Basic Key Operation Sequence and Parameter Map
2. Lists of Parameters

1. Basic Key Operation Sequence and Parameter Map

NOTE

Changing the registered value of a setup parameter
may cause the registered value of an operating pa-
rameter to be initialized automatically. Thus, when
you have changed a setup parameter, always check
that the registered value of the operating parameter
is appropriate. If it is initialized to default, reset it to
the required value.

P V

AL1

2

3

4

S E T / E N T

P V

AL1

2

3

4

S E T / E N T

P V

AL1

2

3

4

S E T / E N T

P V

AL1

2

3

4

S E T / E N T

P V

AL1

2

3

4

S E T / E N T

P V

AL1

2

3

4

S E T / E N T

Yes

No

Alarm-4 setpoint 

C

B

Menu

Displayed only for UM350-

1, UM350-

2, UM330-

1, UM330-

2

Menu

A

If you become unsure of key operation during parameter 

setting, hold down the           key for more than 

3 seconds.  This returns you to the display at 

power-on (i.e., operating display).

?

SET/ENT

SET/ENT

key

SET/ENT

SET/ENT

key

SET/ENT

key

SET/ENT

key

Alarm-3 setpoint 

Alarm-1 setpoint 

Alarm-2 setpoint 

PV peak value

PV bottom value

PV input bias

PV input filter

Nothing is displayed.

Displays the

 operating

 parameter menu

 symbol “OP.PA.”

Displays a setpoint.

Displays a

 parameter

 symbol.

SET/ENT

Determine PV input type first. 

Settings herein are described in “

2. Setting PV Input Type 

(Setting First at Power-on) ” in 

Initial Settings User’s Manual 

 . 

 or        key

Password input

(No password is required 
when PWD = 0.)

Description of Operating Parameter Setting Display

Description of Operating Parameter Menu Display 

Power on

Display?

IN = OFF

Displays PV.

To switch the parameter display, press the             key. 

Display example

Display example

After PV input type (IN), input parameters 
such as PV input unit (UNIT), maximum 
value of PV input range  (RH), and 
minimum value of PV input range  (RL) 
will be displayed. 

Press the               key to register 
the value. 

2.

1.

Use the        or        key to set a numerical 
value.  See 

Instrument Input Range Codes  

in  

Initial Settings User’s Manual 

 . 

Blinks during

change.

Press this key for more 

than 3 seconds to 

move to the operating 

parameter setting 

display. 

SET/ENT

key

Press this key for 

more than 3 seconds

to move to the 

operating

 display. 

SET/ENT

key

Operating Display 

Operating Parameter Setting Display

B

C

Displayed first after power on.

Menu

Displayed only for indicators 
with communication functions

or

key

A

SET/ENT

key

SET/ENT

key

SET/ENT

key

SET/ENT

key

Alarm-2 type

Alarm-3 type

Alarm-1 hysteresis

Alarm-2 hysteresis

Alarm-3 hysteresis

Alarm-1 delay timer

Alarm-2 delay timer

Alarm-3 delay timer

Alarm-4 hysteresis

Alarm-4 type

Key lock

Alarm-4 delay timer

P V

AL1

2

3

4

S E T / E N T

P V

AL1

2

3

4

S E T / E N T

Displays a setpoint.

Displays a parameter.

Nothing is displayed.

Displays a menu, such as 
FUNC or I/O.

This parameter is not to be set.

Displayed only for UM350-

1,

UM350-

2, UM330-

1, UM330-

2.

Displayed only for UM350-

1,

UM350-

2, UM330-

1, UM330-

2.

Displayed only for UM350-

1,

UM350-

2, UM330-

1, UM330-

2.

1. Setting display can be switched (moved) using the            key. 

2. A numerical value is changed by 

   (1) Using the       or       key to change a displayed value (decimal point blinking) and 

   (2) Pressing the           key to register it. 

3. Pressing the           key on an operating display (for more than 3 seconds) brings you to the 

operating parameter setting display. 

4. Pressing the           key on the operating parameter setting display (for more than 3 seconds) 

returns you to the operating display. 

5. Pressing the           key on the setup parameter setting display (for more than 3 seconds) 

returns you to the operating display.  You cannot return to the operating parameter setting
display from the setup parameter setting display. 

Basic Key Operation Sequence

SET/ENT

SET/ENT

SET/ENT

SET/ENT

SET/ENT

Description of Setup Parameter Menu Display

Description of Setup Parameter Setting Display

Alarm/Communication 

related

Input related

Alarm-1 type

Protocol selection

Baud rate

Stop bit

Data length

Address

Minimum response time

Parity

PV input type

(PV INPUT terminals)

PV input unit

Maximum value of PV input range

PV input decimal point position

(displayed at voltage input)

Selection of 

PV input burnout action

Presence/absence of PV input 

reference junction compensation

Maximum value of PV input scale 

(displayed at voltage input)

Minimum value of PV input scale 

(displayed at voltage input)

Minimum value of PV input range

Retransmission output type

Maximum value of 

retransmission output scale

Minimum value of 

retransmission output scale

DI function selection

SELECT display-1 registration

SELECT display-2 registration

SELECT display-3 registration

SELECT display-4 registration

Password setting

Press this key for 

more than 3 seconds

to move to the 

operating

 display. 

SET/ENT

key

Setup Parameter Setting Display

IM 05F01D02-03E

User’s
Manual

4th Edition: Jan 31, 2005

Models UM350 / UM330
Digital Indicator with Alarms
User’s Manual

   Parameters