1.  PREFACE

Thank you for purchasing our temperature sensor.
This User’s Manual gives instructions on handling, 

wiring, and maintenance of temperature sensors.
In order for the temperature sensor to be fully functional 

and to operate in an efficient manner, the manual must 

be carefully read.

■ Notes on the User’s Manual

• In no case does this manual guarantee the 

merchantability of the transmitter or its adaptability to 

a specific client need.

• Changes to specifications, structure, and 

components used may not lead to the revision of this 

manual unless such changes affect the function and 

performance of the products.

■ Warranty

• The warranty period of the instrument is written 

on the estimate sheet that is included with your 

purchase.

  Any trouble arising during the warranty period shall 

be repaired free of charge.

• Whether or not the defective instrument is repaired 

free of charge depends on the result of our 

inspection.

● The following conditions shall not be eligible for 

charge-exempt repair.

• Problems caused by improper or insufficient 

maintenance on the part of the customer.

• Trouble or damage caused by mishandling, 

misusage, or storage that exceeds the design or 

specification requirements.

• Trouble or damage was caused by modification or 

repair that was handled by a party or parties other 

than our consigned agent.

• Trouble or damage was caused by fire, earthquake, 

wind or flood damage, lightning strikes or other acts 

of God that are not directly a result of problems with 

this instrument.

■ Checking items after unpacking

When the temperature sensor is delivered, check 

the appearance for damage, and also verify that the 

configuration indicated in the “Model and Suffix Code” 

is in compliance with the specifications written on the 

order sheet.

CAUTION

Do not change the circuit or parts. The instrument 

modification will void the explosion proof 

certification.

2.  Notes on Safety

It is absolutely imperative that users of this equipment 

read and observe the safety instructions mentioned in 

this manual in order to ensure the protection and safety 

of operators.

2.1  Installation

• Lead cables linked with the temperature sensor, 

such as a compensating lead cable or extension lead 

cable, must be connected to terminals of receiving 

instruments. An incorrect connection may cause a fire 

or an explosion.

• When the temperature sensor is dropped, people 

may be injured since some temperature sensors are 

heavy. Pay attention to the handling of temperature 

sensors, especially resistance thermometers with 

ceramic insulators or protections, which are very 

delicate.

• Temperature sensors of flameproof type are 

approved when that they are used under 60°C or 

below, and that of temperature for Intrinsically safe 

type is 55°C or below.

  Confirm the ambient temperature is in accordance 

with those conditions.

• After wiring, confirm if O-ring packing is furnished 

and then close the cover surely in order to prevent 

permeation of dust or water. Especially for the 

explosion proof type, fasten the cover firmly using a 

hexagonal 17 mm wrench.

  Otherwise, it may be declined the capability of the 

explosion proof.

• Screws or flanges are used for installation of 

temperature sensors. In case of screwing, apply 

sealing tape or sealing agent for tapered thread and 

apply O-ring gaskets for parallel thread. Then fasten 

them firmly. In case of flange connection, insert 

specified gaskets and screw up all bolts equally.

■ Handling cautions for intrinsically safe type

TIIS intrinsically safe type (i3aG5)

Type

TC

TD

RB

Certification number

T28123

T28124

T28125

Combined barrier

BARD200

Two or less BARD200

Lext ≤ 2.2 mH

Cext ≤ 1 μF

BARD300

Internal inductance Lint

≤ 20 μH

Internal capacitance Cint

≤ 2 nF

Ambient temperature Ta

–10°C ≤ Ta ≤ 55°C (–14°F ≤ Ta ≤ 131°F)

Temperature Sensors

2nd Edition: July 2011(YK)

All Rights Reserved, Copyright © 2003, Yokogawa Electric Corporation

IM 06B00A01-01EN

IM 06B00A01-01EN

2nd Edition

Reviews: