IM 12B03D01-01E
5-2
5. Keypad and Display Functions
5.1 Keypad Functions
POWER
: Power On/Off key
Pressing and holding this key for at least one second when nothing is displayed on the
LCD, will turn the meter on. The meter will be turned off by pressing and holding this
key for at least two seconds when the meter is on. If no keys are pressed for a preset
time, the meter turns off power automatically. (Refer to Section 5.3 (7), “Set Auto Power
Off time (A.oFF) panel.”)
CAL
: Calibration key
When pressed during measurement,
mark turns on and the meter moves to
calibration mode. To return to measurement mode, press
CAL
or
MEAS
key.
HOLD
: HOLD key
When pressed during measurement,
mark turns on and the currently displayed
measured pH value and temperature are held. Pressing
HOLD
or
MEAS
key will turn
mark off and return the meter to measurement mode.
DATA
: DATA key
When pressed during measurement,
mark flash and the currently displayed
measured pH value and temperature are held temporarily. Pressing
F/ENT
key while
mark is flashing, will store the held data in memory. After the data is stored
successfully, the meter returns to measurement mode automatically. To cancel data
storage, press
DATA
or
MEAS
key while
mark is flashing.
mark will
turn off and the meter will return to measurement mode.
MEAS
: Measurement key
In measurement mode each press of this key cycles through three measurement display
panels. (Refer to Section 3.3, “Measurement Display Panel.”) Pressing this key in other
modes will return the meter to measurement mode. If you want to cancel any operation,
press this key to return to measurement mode.
: Setting change keys
Used to change settings.
Summary of Contents for PH71
Page 1: ...User s Manual IM 12B03D01 01E Model PH71 Personal pH Meter IM 12B03D01 01E 3rd Edition ...
Page 7: ...IM 12B03D01 01E 6 Contents ...
Page 17: ...IM 12B03D01 01E 1 10 1 Outline ...
Page 23: ...IM 12B03D01 01E 2 6 2 Preparation ...
Page 35: ...IM 12B03D01 01E 4 8 4 Calibration ...
Page 49: ...IM 12B03D01 01E 5 14 5 Keypad and Display Functions ...
Page 57: ...IM 12B03D01 01E 6 8 6 Maintenance ...
Page 73: ...IM 12B03D01 01E 8 10 8 Technical Information ...
Page 79: ...IM 12B03D01 01E 6 Appendix ...
Page 81: ...IM 12B03D01 01E MSDS 2 MSDS ...
Page 82: ...IM 12B03D01 01E MSDS 3 MSDS ...
Page 83: ...IM 12B03D01 01E MSDS 4 MSDS ...
Page 84: ...IM 12B03D01 01E MSDS 5 MSDS ...
Page 85: ...IM 12B03D01 01E MSDS 6 MSDS ...
Page 86: ...IM 12B03D01 01E MSDS 7 MSDS ...
Page 87: ...IM 12B03D01 01E MSDS 8 MSDS ...
Page 88: ...IM 12B03D01 01E MSDS 9 MSDS ...
Page 89: ...IM 12B03D01 01E MSDS 10 MSDS ...
Page 90: ...IM 12B03D01 01E MSDS 11 MSDS ...
Page 91: ...IM 12B03D01 01E MSDS 12 MSDS ...
Page 92: ...IM 12B03D01 01E MSDS 13 MSDS ...
Page 93: ...IM 12B03D01 01E MSDS 14 MSDS ...
Page 94: ...IM 12B03D01 01E MSDS 15 MSDS ...
Page 95: ...IM 12B03D01 01E MSDS 16 MSDS ...