4.3.3 Turning on/off the RJC Using the Switches on the
Front Panel.

This operation is only for thermocouple input.
Turn the selection switch to “7”.  Turn the adjustment switch coun-
terclockwise to turn off the RJC sensor after 1 second.  Turn the
adjustment switch clockwise to turn on the RJC sensor after 1
second.

NOTE

Be sure to set the selection switch back to the position
“0” after each adjustment.  Otherwise it may cause an in-
correct operation or malfunction because the positions
other than “0” are adjustment modes.

When the selection switch is set to the positions other
than “0”, the setting tool can not be used for the setting.

The RJC is turned on when the power is turned on again
after turned off.

5. SETTING PARAMETERS

Set the parameters using a PC (VJ77 Parameter Setting Tool) or the
Handy Terminal.  Refer to “6. List of Parameters” in this manual and the
User’s Manual for VJ77 PC-based Parameters Setting Tool (IM
77J01J77-01E) or the User’s Manual for JHT200 Handy Terminal (IM
JF81-02E).  Parameters are indicated inside the [  ].
The initial value of the input range is set up according to the selected
values of the input sensor type, input type and temperature unit.
Set the parameters as follows.

Setting regarding to the input: set sequentially from 1.
(1) Set the input sensor type.
(2) Set the input type.
(3) Set the temperature unit for temperature input.
(4) Set the input range.

5.1

Setting Thermocouple Type

Set the thermocouple type to be connected to the input in [D08: TC
TYPE].

Display

TYPE K

TYPE E

TYPE J

TYPE T

TYPE W3

Measuring Range

270 to 1372 

C

270 to 1000 

C

210 to 1200 

C

270 to   400

C

0 to 2300 

C

3mV

or more

Display

TYPE R

TYPE S

TYPE B

TYPE N

TYPE W5

 Measuring

span

3mV

or more

 Measuring

span

Measuring Range

50 to 1768 

C

50 to 1768 

C

0 to 1820 

C

270 to 1300 

C

0 to 2300 

C

TYPE W3:  W97Re3-W75Re25

(Tungsten 97% Rhenium 3% - Tungsten 75% Rhenium 25%)

The abbreviation of ASTM E988 Standard.

TYPE W5: W95Re5-W74Re26

(Tungsten 95% Rhenium 5% - Tungsten 74% Rhenium 26%)
The abbreviation of ASTM E988 Standard.

5.2

Setting RTD Type

Set the RTD type to be connected to the input in [D09: RTD TYPE].

Display

Pt100-68

JPt100

Pt50

Pt100-90

Type of Input

Pt100 (IPTS-68: JIS'89)

JPt100 (JIS'89)

Pt50 (JIS'81)

Pt100 (ITS-90: JIS'97)

Measuring range

200 to 660 

°

C

200 to 510 

°

C

200 to 649 

°

C

200 to 850 

°

C

Measuring span

10

°

or more

JPt100 (JIS '89) : R0 = 100 

, R100/R0 = 1.3916

Pt100 (IPTS-68) : R0 = 100 

, R100/R0 = 1.3850

Pt100 (ITS-90)

: R0 = 100 

, R100/R0 = 1.3851

5.3

Setting Temperature Unit

Set the temperature unit of the input range in [D19: UNIT].

5.4

Setting Burnout Action

Set the burnout action in [D43:BURN OUT].
Set "OFF", "UP", or "DOWN."

NOTE

Changing the input range and the burnout action
direction resets the input adjusted value and the wiring
resistance corrected value.

Execute the wiring resistance correction when the
burnout action direction or input wiring is changed.

5.5

Setting Input Range

Set the input range 0% in [D27:INPUT1L_RNG], and the input range
100% in [D28:INPUT1H_RNG].

5.6

Correcting Wiring Resistance

Correct the wiring resistance in [P01:WIRING R].
Select “EXECUTE” for correction, and “RESET” for resetting the cor-
rected value.
Perform wiring as the figure shown in “4.3.2 Correcting Wiring Resis-
tance Using the Switches on the Front Panel” before correcting the wir-
ing resistance.

6.

LIST OF PARAMETERS

A

A01

A07

A54

A56

A58

A60

B

B01

B07

B60

D

D01

D02

D03

D04

D07

D08

D09

D13

D19

D27

D28

D38

D39

D43

D49

D60

P

P01

P02

P03

P26

P27

P60

Q

Q01

Q03

Q60

MODEL

TAG NO

SELF CHK

DISPLAY1

INPUT1

OUTPUT1

STATUS

REV NO

MENU REV

SELF CHK

DISPLAY2

INPUT1

OUTPUT1

SELF CHK

SET (I/O)

TAG NO.1

TAG NO.2

COMMENT1

COMMENT2

SENSOR TYPE

TC TYPE

RTD TYPE

LINEARIZE

UNIT

INPUT1 L_RNG

INPUT1 H_RNG

OUT1 L_RNG

OUT1 H_RNG

BURN OUT

OUT1 DR

SELF CHK

ADJUST

WIRING R

IN1 ZERO ADJ

IN1 SPAN ADJ

OUT1ZERO ADJ

OUT1SPAN ADJ

SELF CHK

TEST

RJC

OUT1 TEST

SELF CHK

Parameter Display

Item

Model

Tag number

Self-check result

Display1

Input-1

Output-1

Status *

1

REV No.

MENU REV

Self-check result

Display2

Input-1

Output-1

Self-check result

Setting (I/O)

Tag number-1

Tag number-2

Comment-1

Comment-2

Input sensor type

Thermocouple type 

*2

RTD type 

*3

Linearization 

*4

Temperature unit 

*2, *3

Input-1 low range

Input-1 high range

Output-1 low range

Output-1 high range

Burnout

Direction of output-1 action

Self-check result

Adjustment

Wiring resistance correction

Input-1 zero adjustment 

Input-1 span adjustment

Output-1 zero adjustment 

Output-1 span adjustment

Self-check result

Test

ON/OFF of RJC 

*2

Forced output-1

Self-check result

*1 The displayed status is to let the service staff know the past records of the 

product.

*2 Displayed only when the parameter D07:SENSOR TYPE is set to “TC”.
*3 Displayed only when the parameter D07:SENSOR TYPE is set to “RTD”.
*4 Displayed only when the parameter D07:SENSOR TYPE is set to “mV”.

Reviews: