Introduction

This guideline explains how to improve communication quality of FN110 Field Wireless Communication Module 

(hereafter simply referred to as FN110) by attaching F9092EY (FN110 Attachment). This guideline also explains 

the effect of F9092EY.

. Regarding.This.Manual

•  The contents of this manual are subject to change without prior notice if there are future performance and/

or function improvements.

•  If any question arises or errors are found, or if any information is missing from this manual, please inform 

the nearest Yokogawa Sales office.

•  All rights reserved. No part of this manual may be reproduced in any from without Yokogawa’s written per-

mission.

. Reference.Documents

•  For details on installing field wireless devices in a system with the YFGW410 field wireless management 

station and YFGW510 field wireless access point, refer to Guidelines for Layout and Installation of Field 

Wireless Devices (TI 01W01A51-12EN).

•  For the usage of FN110, refer to FN110 User’s Manual (IM 01W03B01-01EN) and F9092EY User’s Manual 

(IM 01W03B01-02EN).

Revision.Information

Title:.Guidelines.for.Using.F9092EY.(FN110.Attachment)
Manual.No.:.TI.01W03A51-01EN

Edition

Date

Page

Revised.Item

1st

August 2015

-

New Issue

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation

Summary of Contents for FN110

Page 1: ...Musashino shi Tokyo 180 8750 Japan Tel 81 422 52 5634 Fax 81 422 52 9802 Contents Introduction 2 Revision Information 2 1 Usage of F9092EY 3 1 1 Purpose of using F9092EY 3 1 2 Guidelines on whether u...

Page 2: ...l please inform the nearest Yokogawa Sales office All rights reserved No part of this manual may be reproduced in any from without Yokogawa s written per mission Reference Documents For details on ins...

Page 3: ...ws the same installation point optimization as other Yokogawa field wireless devices 1 2 Guidelines on whether using F9092EY is necessary 1 Newly installed FN110 Using F9092EY is recommended 2 Existin...

Page 4: ...emote antenna cable to prevent obstacles from affecting wireless signals Unlike other Yokogawa wireless field devices FN110 does not suffer from signal attenuation by a remote antenna cable 5 Install...

Page 5: ...bracket to find the position with the lowest PER Adjust the bracket up or down 2 inch pipe Bracket FN110 2 inch pipe Bracket FN110 a Direct Mounting b Using Remote Antenna Cable Figure 1 4 1 Vertical...

Page 6: ...adiation pattern and increases the chance of improving communication quality Figure 2 illustrates the radiation pattern of FN110 before and after F9092EY applied using F9092EY smoothens the radiation...

Page 7: ...on Note 1 Attachment Dimension 50 mm H24 mm Material 316 SST t 1 0 mm Weight 34 g 2 Holder 1 Dimension W35 mm D28 1 mm H18 mm Material 316 SST t 1 5 mm Weight 12 g 3 Holder 2 Dimension W35 mm D1 5 mm...

Reviews: