IM 01C25B01-01E
9-10
9. GENERAL SPECIFICATIONS
9.3 OPTIONAL SPECIFICATIONS
T0912.EPS
Item
Description
Code
Factory Mutual (FM)
CSA Explosionproof Approval *
2
[For CSA C22.2]
Explosionproof for Class I, Division 1, Groups B, C and D
Dustignitionproof for Class II/III, Division 1, Groups E, F and G
[For CSA E60079]
Flameproof for Zone1, Ex d IIC T6...T4 Enclosure IP66 and IP67
Canadian Standards
Association (CSA)
CSA Intrinsically safe Approval *
2
*
3
[For CSA C22.2]
Intrinsically safe for Class I, Division 1, Groups A, B, C and D, Class II, Division 1,
Groups E,F and G, Class III, Division 1
Nonincendive for Class I, Division 2, Groups A, B, C and D, Class II, Division 2,
Groups E,F and G, Class III, Division 1
[For CSA E60079]
Ex ia IIC T4, Ex nL IIC T4
CENELEC ATEX (KEMA) Intrinsically safe Approval *
1
*
3
II 1G EEx ia IIC T4
FM Intrinsically safe Approval *
1
*
3
Intrinsically Safe for Class I, Division 1, Groups A, B, C and D, Class II, Division 1,
Groups E, F and G and Class III, Division 1 Hazardous Locations.
Nonincendive for Class I, Division 2, Groups A, B, C and D, Class II, Division. 2,
Groups F and G, and Class III, Division 1 Hazardous Locations.
CENELEC ATEX (KEMA) Flameproof Approval *
1
II 2G EExd IIC T4, T5, T6
FM Explosionproof Approval *
1
Explosionproof for Class I, Division 1, Groups B, C and D
Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G
Hazardous (classified) locations, indoors and outdoors (NEMA 4X)
Combined FF1 and FS1 *
1
*
3
Combined CF1 and CS1 *
2
*
3
FF1
FS1
KF2
KS2
CF1
CS1
CU1
Combined KF2, KS2 and Type n *
1
*
3
Type n: II 3G EEx nL IIC T4
CENELEC ATEX
KU2
FU1
IECEx Scheme
IECEx Intrinsically safe, type n and flameproof Approval *
1
*
3
Intrinsically safe and type n [No. IECEx CSA 05.0005]
Ex ia IIC T4, Ex nL IIC T4
Flameproof [No. IECEx CSA 05.0002]
Flameproof for Zone1, Ex d IIC T6...T4
SU2
Contact Yokogawa representative for the codes indicated as ‘-’.
*1: Applicable for Electrical connection code 2, 4, 7, and 9.
*2: Applicable for Electrical connection code 2 and 7.
*3: Not applicable for option code /AL.