21-6
IM DLM3054-01EN
Network Printer (Net Print)
You can print screen captures on a network printer.
The instrument can print to the following printers.
• HP inkjet printers (HP InkJet)
• HP Laser printers (HP Laser)
LPR Servers (LPR Server)
Specify the IP address of the printer server that the instrument will connect to. In a network with a DNS server,
you can specify the host name and domain name instead of the IP address.
LPR is a protocol used to print over a TCP/IP network.
LPR Name (LPR Name)
The name of the shared printer that the instrument will connect to.
Timeout (Timeout)
If the instrument cannot print for a certain amount of time, it disconnects from the network printer.
Selectable range: 0 s to 60 s
SNTP (SNTP)
The instrument clock can be set using Simple Network Time Protocol (SNTP). The instrument can be configured
to automatically adjust its clock when it is turned on.
SNTP Server (SNTP Server)
Specify the IP address of the SNTP server that the instrument will use. In a network with a DNS server, you can
specify the host name and domain name instead of the IP address.
Timeout (Timeout)
If the instrument cannot connect to the SNTP server for a certain amount of time, it aborts the operation.
Selectable range: 1 s to 60 s
Executing Time Adjustment (Set)
The instrument clock is synchronized to the SNTP server clock.
Automatic Adjustment (Adjust at Power On)
You can configure the instrument so that its clock is automatically synchronized to the SNTP server clock when
the instrument is turned on when it is connected to the network.
• If the time difference from GMT (Greenwich Mean Time) is set in the date/time setting, the instrument will
make appropriate adjustments to the time information received from the SNTP server.
• If you do not want the instrument to synchronize with an SNTP server, do not set the SNTP server IP
address.
21 Ethernet Communication (Network)