background image

5-75

IM 701730-17E

Commands

5

:MEASure:CONSt<x>

Function

Sets the constants to be used in the automated
measurement of waveform parameters of Dual
Area or queries the current setting.

Syntax

:MEASure:CONSt<x> {<NRf>}
:MEASure:CONSt<x>?

<NRf>=–9.9999E+30 to 9.9999E+30
<x>=1 to 4

Example

:MEASURE:CONST1 1.0000E+00
:MEASURE:CONST1? ->
:MEASURE:CONST1 1.0000E+00

:MEASure:CYCLe?

Function

Queries all settings related to the periodic
statistical processing of the automated
measurement of waveform parameters (Cycle
Statistics).

Syntax

:MEASure:CYCLe?

Example

:MEASURE:CYCLE? ->
:MEASURE:CYCLE:TRACE 1

:MEASure:CYCLe:ABORt

Function

Aborts the periodic statistical processing of the
automated measurement of waveform
parameters (Cycle Statistics).

Syntax

:MEASure:CYCLe:ABORt

Example

:MEASURE:CYCLE:ABORT

:MEASure:CYCLe:EXECute

Function

Executes the periodic statistical processing of
the automated measurement of waveform
parameters (Cycle Statistics).

Syntax

:MEASure:CYCLe:EXECute

Example

:MEASURE:CYCLE:EXECUTE

:MEASure:CYCLe:TRACe

Function

Sets the waveform used to determine the
period for the periodic statistical processing of
automated measurement of waveform
parameters (Cycle Statistics) or queries the
current setting.

Syntax

:MEASure:CYCLe:TRACe {OWN|<NRf>|
MATH<x>}
:MEASure:CYCLe:TRACe?

<NRf>=1 to 4 (1 to 2 on the DL1720E)
<x>=1 or 2 (1 on the DL1720E)

Example

:MEASURE:CYCLE:TRACE 1
:MEASURE:CYCLE:TRACE? ->
:MEASURE:CYCLE:TRACE 1

:MEASure:HISTory:ABORt

Function

Aborts the statistical processing within the
historical data of the automated measurement
of waveform parameters (History Statistics).

Syntax

:MEASure:HISTory:ABORt

Example

:MEASURE:HISTORY:ABORT

:MEASure:HISTory:EXECute

Function

Executes the statistical processing within the
historical data of the automated measurement
of waveform parameters (History Statistics).

Syntax

:MEASure:HISTory:EXECute

Example

:MEASURE:HISTORY:EXECUTE

:MEASure:MODE

Function

Sets the mode of the automated measurement
of waveform parameters or queries the current
setting.

Syntax

:MEASure:MODE {OFF|ON|STATistics|
CYCLE|HISTory}
:MEASure:MODE?

Example

:MEASURE:MODE ON
:MEASURE:MODE? -> :MEASURE:MODE ON

:MEASure:ONECycle

Function

Turns ON/OFF the automated measurement in
the one-cycle mode or queries the current
setting.

Syntax

:MEASure:ONECycle {<Boolean>}
:MEASure:ONECycle?

Example

:MEASURE:ONECYCLE ON
:MEASURE:ONECYCLE ->
:MEASURE:ONECYCLE 1

:MEASure:TLINkage<x>

Function

Turns ON/OFF the linked movement of the
cursors in the automated measurement of
waveform parameters or queries the current
setting.

Syntax

:MEASure:TLINkage<x> {<Boolean>}
:MEASure:TLINkage<x>?

<x>=1, 2

Example

:MEASURE:TLINKAGE1 ON
:MEASURE:TLINKAGE1 ->
:MEASURE:TLINKAGE1 1

Description

:MEASURE:TLINKAGE1

” sets the links for T-

Range1 and T-Range2 or queries the current
settings.  “

:MEASURE:TLINKAGE2

” sets the

links for T-Range3 and T-Range4 or queries the
current settings.

:MEASure:TRANge<x> (Time Range)

Function

Sets the measurement range of the automated
measurement of waveform parameters or
queries the current setting.

Syntax

:MEASure:TRANge<x> {<NRf>,<NRf>}
:MEASure:TRANge<x>?

<x>=1, 2
<NRf>=–5 to 5 div (10 div/displayed record

length steps)

Example

:MEASURE:TRANGE1 -4,4
:MEASURE:TRANGE1? ->
:MEASURE:TRANGE1 -4.00E+00,4.00E+00

Description

:Measure:TRANge1

” sets the measurement

range of Area1 during normal measurement
and during measurement on dual areas or
queries the current setting.

:Measure:TRANge2

” sets the measurement

range of Area2 during the measurement on
dual areas or queries the current setting.

5.17 MEASure Group

Summary of Contents for DL1720E

Page 1: ...Digital Oscilloscope Communication Interface IM 701730 17E 1st Edition DL1720E DL1740E DL1740EL...

Page 2: ...ions Operation Guide and basic operating procedures of the DL1720E DL1740E DL1740EL DL1740E DL1740EL IM 701730 51E Describes the serial bus signal analysis Serial Bus Signal Analisis function option F...

Page 3: ...f Adobe Systems incorporated For purposes of this manual the TM and symbols do not accompany their respective trademark names or registered trademark names The TCP IP software and TCP IP related docum...

Page 4: ...f the Ethernet Interface Option Describes the functions and specifications of the Ethernet interface Chapter 4 Before Programming Describes formats used when sending a command Chapter 5 Commands Descr...

Page 5: ...eatures in descriptions Procedure Carry out steps in the order shown The operating procedures are given with the assumption that you are not familiar with the operation Thus it may not be necessary to...

Page 6: ...mbols are referred to as BNF notation Backus Naur Form For detailed information refer to page 4 5 to 4 6 Symbol Description Example Example of Input Defined value CHANnel x x 1 to 4 CHANNEL2 One of th...

Page 7: ...ce Option 3 1 Names of the Parts and their Functions 3 1 3 2 Ethernet Interface Functions and Specifications 3 2 3 3 Connection via the Ethernet Interface 3 4 3 4 Setting up this Instrument Network 3...

Page 8: ...rt 6 1 Overview of the Status Report 6 1 6 2 Status Byte 6 2 6 3 Standard Event Register 6 3 6 4 Extended Event Register 6 4 6 5 Output Queue and Error Queue 6 5 Chapter 7 Sample Program 7 1 Before Pr...

Page 9: ...20pF 40Vpk _ MISC Key Page 1 5 Press to enter the communication settings such as the address and the timeout SHIFT Key CLEAR TRACE Key Press to switch from remote mode to local mode which allows key o...

Page 10: ...However it is not possible to connect more than 15 items of equipment including the controller to a single bus If you connect the instrument to more than one item of equipment make sure that a differ...

Page 11: ...al to Remote Mode Remote mode is activated when a REN Remote Enable message is received from a controller while local mode is active REMOTE is displayed on the upper right of the screen All front pane...

Page 12: ...sten Address no talk only capability Listener L4 Basic listener capability unlisten on MTA My Talk Address no listen only capability Service Request SR1 Full service request capability Remote Local RL...

Page 13: ...ey 5 Turn the jog shuttle to set the desired address Explanation When you make settings which can be made using the front panel keys of the instrument or when you output setup data or waveform data us...

Page 14: ...T Take Control are not supported Response to a Multi Line Message Universal Command LLO Local LockOut Invalidates SHIFT CLEAR on the front panel to disable switching to local mode DCL Device CLear Sam...

Page 15: ...ut DCL Device CLear PPU Parallel Poll Unconfigure SPE Serial Poll Enable SPD Serial Poll Disable In addition to the above commands a listener address talker address on secondary command can be sent in...

Page 16: ...pk _ MISC Key Page 2 5 Press to enter the communication settings such as the ID value SHIFT Key CLEAR TRACE Key Press to switch from remote mode to local mode which allows key operation However this i...

Page 17: ...is required for connection to the PC Data Transfer Rate The table below shows approximate response times for output of waveform data assuming the following configuration Model 701730 Controller PC Pe...

Page 18: ...When the DL1720E DL1740E DL1740EL receives a COMMunicate REMote OFF command from the PC the DL1720E DL1740E DL1740EL switches to the local mode regardless of the local lock condition REMOTE indication...

Page 19: ...multiple devices using USB hubs connect the instrument to the USB hub that is closest to the controller Do not mistakenly insert the USB cable to the GO NO GO output terminal This may cause damage to...

Page 20: ...key 5 Turn the jog shuttle to set the ID value Explanation Carry out the following settings when using a controller to set information that can be specified through key operation on the instrument or...

Page 21: ...k _ _ 1M 20pF 40Vpk _ MISC Key Page 3 5 Press to confirm the user name and password SHIFT Key CLEAR TRACE Key Press to switch from remote mode to local mode which allows key operation However this is...

Page 22: ...s approx 1 9 s 100000 approx 182 1 ms approx 401 5 ms approx 19 6 s 1000000 approx 1908 8 ms approx 3006 3 ms approx 197 2 s Switching between Remote and Local Mode When Switched from Local to Remote...

Page 23: ...User Verification Function The user must enter a user name and password for the Ethernet interface when connecting to the network The user name and password is set on the instrument in the Remote Cntl...

Page 24: ...ble or STP Cable Straight Cable Network Card Ethernet Personal Computer or Workstation DL1720E DL1740E DL1740EL 100BASE TX Compatible Hub or Router PERIPHERAL USB USB ISM 1 A N200 LINK ACT ETHERNET 10...

Page 25: ...the User Name If you do not wish to limit access use the anonymous setting If access is to be limited enter a user name of 15 characters or less 6 Use the jog shuttle SELECT to enter the Password of...

Page 26: ...ay be used The default value is anonymous Password Setting 15 characters or less may be used Setting the Timeout Time If the unit is not being accessed at the specified timeout time the connection to...

Page 27: ...nd this instrument during communications Messages sent from the controller to this instrument are called program messages and messages sent back from this instrument to the controller are called respo...

Page 28: ...end another program message until a response message has been received An error will occur if a program message is sent before a response message has been received in its entirety A response message w...

Page 29: ...ble to omit a colon Example ACQuire MODE NORMal STARt PMT When Concatenating Common Commands Common commands defined in IEEE 488 2 1987 are independent of hierarchical level Thus it is not necessary t...

Page 30: ...y levels When Separating Commands with PMT If a terminator is used to separate two commands each command is a separate message Therefore the common header must be typed in for each command even when c...

Page 31: ...ROBe 100 Voltage Time Physical value Frequency Current Example Time axis range TIMebase TDIV 1US Register Register value expressed as either binary octal decimal or hexadecimal Example Extended event...

Page 32: ...F 1 0 When Boolean is expressed in NRf form OFF is selected if the rounded integer value is 0 and ON is selected if the rounded integer is Not 0 A response message is always 1 if the value is ON and 0...

Page 33: ...ter string 1 CASE CASE If you input an NRf value the system converts the value after rounding to the nearest integer to the corresponding 8 character ASCII string If you set the value to 1 the name be...

Page 34: ...p EXECute CASE1 WAI CHANnel1 VDIV PMT The COMMunicate OPSE command is used to designate which commands are to be subject to the WAI command In the above example only auto setup is designated Since a W...

Page 35: ...o judge whether acquisition is in progress or not by reading bit 0 of the condition register Bit 0 is 1 if acquisition is in progress and 0 if acquisition is stopped Example TRIGger MODE SINGle STARt...

Page 36: ...ted to the vertical axis of the channel 5 20 CHANnel x BWIDth Sets the input filter of the channel or queries the current setting 5 20 CHANnel x COUPling Sets the input coupling of the channel or quer...

Page 37: ...r cursors 5 29 CURSor TY MARKer M x Queries all settings related to the specified marker cursor 5 29 CURSor TY MARKer M x JUMP Jumps the marker cursor onto the zoom waveform display frame 5 29 CURSor...

Page 38: ...eform CHANnel x BACK MATH x Sets the colors for waveform and computation channels or queries the current setting 5 36 DISPlay FORMat Sets the display format or queries the current setting 5 36 DISPlay...

Page 39: ...O and also the determination criteria 5 47 GONogo ACTion BUZZer Sets whether or not to sound an alarm when the determination is NO GO or queries the current setting 5 47 GONogo ACTion HCOPy Sets wheth...

Page 40: ...ent setting 5 51 HCOPy Group HCOPy Queries all settings related to the print of the screen image data 5 53 HCOPy ABORt Aborts printing or paper feeding 5 53 HCOPy COMMent Sets comments at the lower se...

Page 41: ...elated to the history search zone 5 59 HISTory ZONE EDIT x Queries all settings related to the search zone of the history search zone 5 59 HISTory ZONE EDIT x CONDition Sets the search condition of th...

Page 42: ...surement of waveform parameters 5 69 MEASure AMODe Sets the normal automated measurement of parameters NORMal and the automated measurement of parameters on dual areas AREA2 or queries the current set...

Page 43: ...re CYCLe ABORt Aborts the periodic statistical processing of the automated measurementof waveform parameters Cycle Statistics 5 75 MEASure CYCLe EXECute Executes the periodic statistical processing of...

Page 44: ...setting 5 80 PRESet CHANnel x USERdefine Queries all preset values when using user type presets 5 80 PRESet CHANnel x USERdefine LEVel Sets the preset value of the user type trigger level or queries...

Page 45: ...aveform number 5 89 SEARch SELect MAXimum Queries the detection count of the search zoom function 5 89 SEARch SPATtern Queries all settings related to the serial pattern search of the search zoom func...

Page 46: ...5 94 STATus SPOLl Executes serial polling 5 94 STOP Group STOP Stops the waveform acquisition 5 94 STORe Group STORe Queries information about the setting parameters that are stored to the internal m...

Page 47: ...orts are sent as an ACTion 5 105 TRIGger ACTion SAVE Sets whether or not to save the waveform data when the action is enabled or queries the current setting 5 105 TRIGger ACTion STARt Starts action on...

Page 48: ...ries the current setting 5 109 TRIGger WIDTh CONDition Sets the trigger condition or queries the current setting 5 110 TRIGger WIDTh TIME x Sets the pulse width or queries the current setting 5 110 TR...

Page 49: ...setting 5 117 ZOOM MODE Sets the zoom waveform display mode or queries the current setting 5 117 ZOOM PLINkage Turns the link ON OFF when moving the zoom box or queries the current setting 5 117 ZOOM...

Page 50: ...about acquisition This allows you to make the same settings that you can make using ACQ on the front panel ACQuire AVERage COUNt Space NRf INFinity EWEight Space NRf CLOCk Space INTernal EXTernal COU...

Page 51: ...ACQuire CLOCk Example ACQUIRE CLOCK INTERNAL ACQUIRE CLOCK ACQUIRE CLOCK INTERNAL ACQuire COUNt Function Sets the number of waveform acquisitions during normal mode envelope mode and box average or q...

Page 52: ...ple CALIBRATE DESKEW CALIBRATE DESKEW MODE 0 TARGET 1 TIME 0 0E 00 CALibrate DESKew MODE Function Turns the skew compensation ON OFF or queries the current setting Syntax CALibrate DESKew MODE Boolean...

Page 53: ...te Function Executes calibration Syntax CALibrate EXECute Example CALIBRATE EXECUTE CALibrate MODE Function Sets queries the ON OFF of the auto calibration Syntax CALibrate MODE AUTO OFF CALibrate Exa...

Page 54: ...n make using VERTICAL CH V DIV CHANnel x BWIDth Space FULL COUPling Space AC DC DC50 GND DISPlay Space OFF ON NRf LABel Space Character string Character string Frequency Voltage Voltage Voltage LSCale...

Page 55: ...d symbols displayed on the keyboard on the screen can be used In ASCII code and are expressed as 1EH and 1FH respectively CHANnel x LSCale Function Queries all settings related to the linear scaling o...

Page 56: ...s the probe attenuation current to voltage conversion ratio of the channel or queries the current setting Syntax CHANnel x PROBe NRf C10 C100 CHANnel x PROBe x 1 to 4 1 to 2 on the DL1720E NRf 1 10 10...

Page 57: ...roup The CLEar command is used to cler the trace This allows you to perform the same operation that you can perform using CLEAR TRACE on the front panel CLEar 5 6 CLEar Group CLEar Function Clears tra...

Page 58: ...ean COMMunicate LOCKout Example COMMUNICATE LOCKOUT ON COMMUNICATE LOCKOUT COMMUNICATE LOCKOUT 1 Description This is an exclusive commandfor the USB interface or Ethernet interface option 5 7 COMMunic...

Page 59: ...ets remote local It is in remote mode when it is set to ON Syntax COMMunicate REMote Boolean COMMunicate REMote Example COMMUNICATE REMOTE ON COMMUNICATE REMOTE COMMUNICATE REMOTE 1 Description This i...

Page 60: ...t you can make using CURSOR on the front panel CURSor TY DEGRee DX DY JUMP Space C1_Z1 C1_Z2 C2_Z1 C2_Z2 POSition x Space NRf REFerence x Space NRf RVALue Space NRf TRACe Space ALL NRf MATH x X x Y x...

Page 61: ...ion x Space NRf TRACe Space ALL NRf MATH x X x Y x XY HORizontal DY POSition x Space NRf TRA Ce Space XY1 XY2 Y x MARKer T POSition Space NRf TRACe Space XY1 XY2 X Y TYPE Space OFF HORizontal VERTical...

Page 62: ...90 CURSor TY DEGRee DX Function Queries the angle difference D between angle cursors in the T Y display Syntax CURSor TY DEGRee DX Example CURSOR TY DEGREE DX CURSOR TY DEGREE DX 180 00000E 00 CURSor...

Page 63: ...TY HORIZONTAL DY CURSOR TY HORIZONTAL DY 3 0000000E 00 Description When the linear scaling is ON the scaled value is queried CURSor TY HORizontal POSition x Function Sets the horizontal cursor positio...

Page 64: ...ARKER M1 POSITION 1 CURSOR TY MARKER M1 POSITION CURSOR TY MARKER M1 POSITION 1 0000000 CURSor TY MARKer M x TRACe Function Sets the waveform on which to use the marker cursor in the T Y display or qu...

Page 65: ...ICAL POSITION1 2 00E 00 CURSo TY VERTical TRACe Function Sets the target waveform of the vertical cursor of the T Y display or queries the current setting Syntax CURSor TY VERTical TRACe NRf MATH x PO...

Page 66: ...00E 03 CURSor XY MARKer TRACe Function Sets the waveform on which to use the marker cursor in the X Y display or quries the current setting DL1740E DL1740EL only Syntax CURSor XY MARKer TRACe XY1 XY2...

Page 67: ...y Syntax CURSor XY VERTical TRACe XY1 XY2 CURSor XY VERTical TRACe Example CURSOR XY VERTICAL TRACE XY1 CURSOR XY VERTICAL TRACE CURSOR XY VERTICAL TRACE XY1 CURSor XY VERTical X x Function Queries th...

Page 68: ...tence COLor PERSistence Space Time INFinity COLor Space RGB INTensity RGB MENU BACK Space NRf NRf NRf DIALog Space NRf NRf NRf FOCus Space NRf NRf NRf FORE Space NRf NRf NRf LINE Space NRf NRf NRf SEL...

Page 69: ...ce NRf MENU Space NRf GRID Space NRf SNAP Space NRf WAVeforn Space NRf INTERpolate Space OFF SINE LINE PULSe MAPPing Space AUTO FIXed USERdefine SMAPping CHANnel x Space NRf MATH x Space NRf SVALue Sp...

Page 70: ...S SNAP 15 15 15 ZONE1 0 0 15 ZONE2 15 4 11 ZONE3 11 15 4 ZONE4 0 7 15 GRID 8 8 8 CURSOR 13 13 13 MARKER 15 15 15 5 9 DISPlay Group DISPlay Function Queries all display settings Syntax DISPay Example D...

Page 71: ...HEXa DISPlay FORMat Example DISPLAY FORMAT QUAD DISPLAY FORMAT DISPLAY FORMAT QUAD Description QUAD and HEXa are not available on the DL1720E 5 9 DISPlay Group DISPlay GRATicule Function Sets queries...

Page 72: ...lects queries whether scaling values are displayed Syntax DISPlay SVALue Boolean DISPlay SVALue Example DISPLAY SVALUE OFF DISPLAY SVALUE DISPLAY SVALUE 0 DISPlay TLABel Trace LABEL Funcion Selects qu...

Page 73: ...Filename JPEG EXECute Space Filename MEASure EXECute Space Filename PNG EXECute Space Filename POSTscript EXECute Space Filename SETup EXECute Space Filename SNAP EXECute Space Filename TIFF EXECute...

Page 74: ...FF ON NRf ASCii EXECute ABORt HISTory Space ONE ALL RANGe Space MAIN Z1 Z2 Z1_Z2 TRACe Space ALL NRf MATH x BINary ABORt HISTory Space ONE ALL RANGe Space MAIN Z1 Z2 Z1_Z2 COMPression Space OFF ON NRf...

Page 75: ...ilename SETup EXECute ABORt SNAP EXECute ABORt NRf MATH x SNAP EXECute PLANe Space NRf ALL UNLoad BINary EXECute TRACe Space ALL 1 FLOPpy can be used when the built in floppy disk drive is available P...

Page 76: ...nd NRf FLOPpy can used when the built in floppy disk drive is available PCCard can be used when the built in PC card drive is available NETWork can be used when the Ethernet interface option is instal...

Page 77: ...ASCii BINary FLOat HISTory Function Sets whether to save all the waveform data or a selected waveorm or queries the current setting Syntax FILE SAVE ASCii BINary FLOat HISTory ONE ALL FILE SAVE ASCii...

Page 78: ...EXECute Function Executes the unloading of the various data that has been loaded This is an overlap command Syntax FILE UNLoad BINary SNAP EXECute Example FILE UNLOAD BINARY EXECUTE FILE UNLoad BINar...

Page 79: ...nd inquiries as when GO NO GO on the front panel is pressed GONogo ABORt ACTion BUZZer Space OFF ON NRf HCOPy Space OFF ON NRf MAIL MODE SAVE Space OFF ON NRf COUNt EXECute LOGic Space AND OR MODE Spa...

Page 80: ...e DONTcare HIGH Space DONTcare DONTcare LOW MAXimum MINimum NOVershoot Space NRf NRf DONTcare DONTcare NWIDth Space DONTcare DONTcare PERiod PNUMber Space NRf NRf DONTcare DONTcare POVershoot PTOPeak...

Page 81: ...n Space OUT IN TRACe Space MATH MODE Space Boolean SEND Space Block data TRANge Space NRf NRf NRf TLINkage Space ON OFF WAIT SEQuence Space SINGle CONTinue STOPcount Space NRf INFinity 1 Can be used w...

Page 82: ...print the screen image to the built in printer optional during NO GO determination or queries the current setting Syntax GONogo ACTion HCOPy Boolean GONogo ACTion HCOPy Example GONOGO ACTION HCOPY OF...

Page 83: ...TEM1 CONDITION OUT GONogo PARameter ITEM x CAUSe Function Queries whether or not the waveform parameter is the cause of the NO GO result Syntax GONogo PARameter ITEM x CAUSe x 1 to 4 Example GONOGO PA...

Page 84: ...on Selects single or continuous action or queries the current setting Syntax GONogo SEQuence CONTinuous SINGle GONogo SEQuence Example GONOGO SEQUENCE SINGLE GONOGO SEQUENCE GONOGO SEQUENCE SINGLE GON...

Page 85: ...H1 and 2 7 to 12 are determination zones 1 to 6 On the DL1720E X 1 2 5 7 8 or 9 1 to 2 are traces 5 is MATH1 7 to 9 are determination zones 1 to 3 NRf 0 to 5 00 div 0 01 steps left and right 0 to 8 00...

Page 86: ...ontain ASCII codes 0AH or 00H that stand for NL Hence care must be taken when programming the controller This command is used to save the zone data to the PC and set the data as zone data on the instr...

Page 87: ...tional built in printer You can make the same settings that you can make by pressing SHIFT then pressing COPY HCOPy ABORt COMMent Space Character string DIRection Space EXTPrinter PRINter NETPrint EXE...

Page 88: ...Rf 1 to 127 Example HCOPY EXTPRINTER SELECT 3 HCOPY EXTPRINTER SELECT HCOPY EXTPRINTER SELECT 3 Description If you specify an address at which no printer is connected an error occurs In this case NAN...

Page 89: ...E HCOPY NETPRINT TYPE PSCRIPT Description NRf is specified only when the type is set to BJ Can be used when the Ethernet interface option is installed HCOPy PRINter Function Queries all settings relat...

Page 90: ...PARameter ITEM x CONDition IN OUT OFF SOURce NRf MATH x TYPE AVERage Space NRf NRf AVGFreq Space AVGPeriod Space BWIDth x Space DELay Space DUTYcycle Space NRf NRf FALL Space FREQuency Space HIGH Spa...

Page 91: ...RECord Space NRf MINimum TIME Space NRf MINimum ZONE EDIT x CONDition Space IN OUT OFF HORizontal Space NRf NRf SOURce Space NRf MATH x VERTical Space NRf NRf LOGic Space AND OR TRANge Space NRf NRf S...

Page 92: ...ls see the User s Manual HISTory EXECute Function Executes the history search This is an overlap command Syntax HISTory EXECute Example HISTORY EXECUTE HISTory DMODe Display Mode Function Sets the dis...

Page 93: ...ameter or queries the current setting Syntax HISTory PARameter LOGic AND OR HISTory PARameter LOGic Example HISTORY PARAMETER LOGIC AND HISTORY PARAMETER LOGIC HISTORY PARAMETER LOGIC AND HISTory PARa...

Page 94: ...ion Use EDIT x to specify the desired search zone HISTory ZONE EDIT x HORizontal Function Sets the horizontal position of the zone of the history search zone or queries the current setting Syntax HIST...

Page 95: ...Ment Space SEND EXECute TONE Space COLor OFF GRAY REVerse COMPression Space OFF ON NRf FORMat Space BMP TIFF PSCript Space NRf SAVE ANAMing ON OFF Space CDIRectory Space Filename NAME Space DRIVe NETW...

Page 96: ...ames or queries the current setting Syntax IMAGe ANAMing Boolean IMAGe SAVE ANAMing Example IMAGE ANAMING ON IMAGE SAVE ANAMING IMAGE SAVE ANAMING 1 IMAGe SAVE CDIRectory Function Changes the director...

Page 97: ...itializing You can make the same settings using the Initialize menu of SETUP on the front panel INITialize EXECute UNDO INITialize EXECute Function Executes initializing Syntax INITialize EXECute Exam...

Page 98: ...ON NRf FFT POINts Space NRf SPOint Space NRf WINDow Space RECTangle HANNing FLATtop SMOothing Space OFF ON NRf LABel Space Character string INTegral SPOint Space NRf OPERation Space PLUS MATH1 NRf NRf...

Page 99: ...SPlay Function Sets whether or not to display computation waveforms or queries the current setting Syntax MATH x DISPlay Boolean MATH x DISPlay x 1 or 2 1 on the DL1720E Example MATH1 DISPLAY ON MATH1...

Page 100: ...ng Syntax MATH x SCALe CENTer NRf MATH x SCALe CENTer x 1 or 2 1 on the DL1720E NRf 9 9999E 30 to 9 9999E 30 Example MATH1 SCALE CENTER 1 MATH1 SCALE CENTER MATH1 SCALE CENTER 1 00000E 00 MATH x SCALe...

Page 101: ...een may not match the names used by communication commands A correspondence table is given in Appendix 4 MEASure CHANnel MATH x x ALL Space OFF ON NRf COPY DELay COUNt SDEViation MAXimum MEAN MEASure...

Page 102: ...STATistics CYCLe HISTory TRANge Space NRf NRf CONSt X Space NRf X COUNt SDEViation MAXimum MEAN MINimum STATe Space OFF ON NRf VALue CYCLe ABORt EXECute x TRACe OWN MATH Space NRf HISTory ABORt EXECut...

Page 103: ...le MiNus PLUS DIVision SDEVitation STATe Space ON OFF Character string UNIT Space USER X Space NRf AREA X TRACe COUNt MAXimum MEAN MINimum NONE x MATH Space Parameter ITEM x CONSt When the target chan...

Page 104: ...MEASURE CHANNEL2 RMS STATE 0 MEASURE CHANNEL2 SDEVIATION STATE 0 MEASURE CHANNEL2 TY1INTEG STATE 0 MEASURE CHANNEL2 TY2INTEG STATE 0 MEASURE CHANNEL2 XY1INTEG STATE 0 MEASURE CHANNEL2 XY2INTEG STATE 0...

Page 105: ...MEASURE MATH2 BWIDTH2 STATE 0 MEASURE MATH2 DUTYCYCLE STATE 0 MEASURE MATH2 FALL STATE 0 MEASURE MATH2 FREQUENCY STATE 0 MEASURE MATH2 HIGH STATE 0 MEASURE MATH2 LOW STATE 0 MEASURE MATH2 MAXIMUM STA...

Page 106: ...ction Copies the ON OFF state of all measurement parameters of one waveform to all other waveforms Syntax MEASure CHANnel x MATH x COPY x of CHANnel x 1 to 4 1 to 2 on the DL1720E x of MATH x 1 or 2 1...

Page 107: ...ANNEL1 DELAY REFERENCE SLOPE MEASURE CHANNEL1 DELAY REFERENCE SLOPE RISE MEASure CHANnel x MATH x DELay REFerence SOURce Function Sets the reference of the delay measurement between waveforms to the t...

Page 108: ...e CHANnel x MATH x DPRoximal UNIT Function Sets the distal mesial and proximal values of the automated measurement of waveform parameters in terms of a voltage or current or queries the current settin...

Page 109: ...on the DL1720E Parameter AVERage AVGFreq AVGPeriod BWIDth1 BWIDth2 DUTYcycle FALL FREQuency HIGH LOW MAXimum MINimum NOVershoot NWIDth PERiod PNUMber POVershoot PTOPeak PWIDth RISE RMS SDEViation TY1I...

Page 110: ...HISTory EXECute Function Executes the statistical processing within the historical data of the automated measurement of waveform parameters History Statistics Syntax MEASure HISTory EXECute Example ME...

Page 111: ...f MATH z NONE CONSt w MEASure USER x AREA y TRACe x 1 to 4 y 1 or 2 NRf 1 to 4 1 to 2 on the DL1720E z 1 or 2 1 on the DL1720E w 1 to 4 Example MEASURE USER1 AREA1 TRACE 1 MEASURE USER1 AREA1 TRACE ME...

Page 112: ...omitted If omitted the newest parameter in history is queried If NRf is appended queries the parameters from the newest waveform in history memory to the NRf waveform MEASure WAIT Function Waits for...

Page 113: ...00 CHANNEL8 0 0E 00 PHASe CHANnel x Function Sets the amount of phase shift of the waveform or queries the current setting Syntax PHASe CHANnel x time PHASe CHANnel x x 1 to 4 1 to 2 on the DL1720E ti...

Page 114: ...the front panel is pressed PRESet ALL PROBe Space NRf C10 C100 TYPE Space CMOS5 CMOS3 ECL USERdefine USERdefine LEVel Space OFFSet Space VDIV Space CHANnel x PROBe Space NRf C10 C100 TYPE Space CMOS5...

Page 115: ...hannels Syntax PRESet ALL USERdefine VDIV voltage voltage 2 mV to 10 V when the probe attenuation is 1 1 See the User s Manual Example PRESET ALL USERDEFINE VDIV 2V Description When set to the current...

Page 116: ...value or queries the current setting Syntax PRESet CHANNEL x USERdefine VDIV voltage PRESet CHANNEL x USERdefine VDIV x 1 to 4 1 to 2 on the DL1720E voltage 2 mV to 10 V when the probe attenuation is...

Page 117: ...These commands can be used to carry out the same operations as when SETUP on the front panel is pressed RECall SETup X EXECute RECall SETup x EXECute Function Recalls the setting parameters from the...

Page 118: ...o make the same settings and inquiries as when SHIFT ZOOM on the front panel is pressed SEARch EDGE COUNt Space NRf HYSTeresis Space NRf LEVel Space Voltage SLOPe Space RISE FALL SOURce Space NRf MATH...

Page 119: ...oltage Voltage NRf CLOCk HYSTeresis Space NRf LEVel Space SLOPe Space FALL RISE SOURce Space NONE NRf SPATtern CLEar CLOCk HYSTeresis Space NRf LEVel Space SLOPe Space FALL RISE SOURce Space NONE NRf...

Page 120: ...e SPATtern EDGE WIDTh PPATtern ASCRoll WIDTh HYSTeresis Space NRf NRf TIME x Space Time LEVel Space POLarity Space HIGH LOW MATH OUT IN SOURce Space NRf x Voltage TYPE Space TIMeout BETWeen When the t...

Page 121: ...on Example SEARCH ASCROLL DIRECTION LEFT SEARCH ASCROLL DIRECTION SEARCH ASCROLL DIRECTION LEFT SEARch ASCRoll SPEed Function Sets the speed for moving the zoom box of the auto scroll when using the s...

Page 122: ...POSition x x 1 or 2 NRf 5 to 5 div 10 div displayed record length steps Example SEARCH POSITION1 2 5 SEARCH POSITION1 SEARCH POSITION1 2 5000000 SEARch PPATtern Function Queries all settings related t...

Page 123: ...channel of the parallel pattern search using the search zoom function or queries the current setting Syntax SEARch PPATtern CLOCk HYSYeresis NRf SEARch PPATtern CLOCk HYSYeresis NRf 0 3 to 4 div 0 1...

Page 124: ...he clock channel of the serial pattern search using the search zoom function or queries the current setting Syntax SEARch SPATtern CLOCk HYSTeresis NRf SEARch SPATtern CLOCk HYSTeresis NRf 0 3 to 4 di...

Page 125: ...32 to 39 x 6 character string bits 40 to 47 x 7 character string bits 48 to 55 x 8 character string bits 56 to 63 The pattern is assigned the pattern number that is selected with the SEARch SPATtern...

Page 126: ...LOW SEARch WIDTh POLarity Example SEARCH WIDTH POLARUTY HIGH SEARCH WIDTH POLARITY SEARCH WIDTH POLARITY HIGH SEARch WIDTh SOURce Function Sets the target waveform of the pulse width search of the sea...

Page 127: ...TART and wait 0 START only No wait 36000 to 1 100 ms resolution wait period START and wait Example SSTART 100 SSTART 0 Description If the specified time period is positive data acquisition is started...

Page 128: ...TER14 NEVER FILTER15 NEVER FILTER16 NEVER QENABLE 1 QMESSAGE 1 STATus CONDition Function Queries the contents of the condition register and clears the register Syntax STATus CONDition Example STATUS C...

Page 129: ...STATus Group 5 26 STOP Group STATus QMESsage Function Selects queries whether message content is appended to responses to STATus ERRor Syntax STATus QMESsage Boolean STATus QMESsage Example STATUS QME...

Page 130: ...are to be stored to the internal memory at the specified number or queries the current setting Syntax STORe SETup x COMMent Character string STORe SETup x COMMent x 1 to 3 Character string Within 8 c...

Page 131: ...F ON NRf LANGuage Space CHINese ENGLish MLANGuage Space CHINese ENGLish JAPANese LCD AUTO BRIGhtness Space NRf MODE Space Time Space OFF ON NRf OCANcel Space OFF ON NRf BATTery MODE TIME Space OFF ON...

Page 132: ...MTTIME 09 00 SYSTem CLOCk SNTP EXECute Functions Execute date and time setting per SNTP server Syntax SYSTem CLOCk SNTP EXECute Example SYSTEM CLOCK SNTP EXECUTE SYSTem CLOCk SNTP GMTTime Functions Se...

Page 133: ...se SYSTem MLANguage Example SYSTEM MLANGUAGE ENGLISH SYSTEM MLANGUAGE SYSTEM MLANGUAGE ENGLISH SYSTem OCANcel Offset Cancel Function Sets whether or not to reflect the offset voltage to the measured r...

Page 134: ...se Example TIMEBASE TIMEBASE SOURCE INTERNAL TDIV 500 0E 06 TIMebase SOURce Function Sets the time base or queries the current setting Syntax TIMebase SOURce EXTernal INTernal TIMebase SOURce Example...

Page 135: ...oup keys SIMPLE and ENHANCED and LEVEL nob and POSITION DELAY TRIGger ABN COUNt Space NRf ACTion BUZZer Space OFF ON NRf STARt STOP SAVE Space OFF ON NRf HCOPy Space OFF ON NRf IMAGe Space OFF ON NRf...

Page 136: ...FALL IN OUT OFF WINDow Space OFF ON NRf HOLDoff TIME Space Time Time BTRigger CHANnel x Space DONTcare HIGH LOW CONDition Space ENTer EXIT DELay Space LOW CLOCk SLOPe Space FALL RISE SOURce Space NRf...

Page 137: ...LEVel Space SLOPe Space BOTH FALL RISE SOURce Space NRf EXTernal LINE SOURce CHANnel x Voltage Frequency Frequency COUPling Space AC DC HFRejection Space OFF PROBe Space NRf HYSTeresis Space HIGH LOW...

Page 138: ...I1080 24 I1080 50 I1080 60 P1080 24 P1080 25 P1080 60 P480 60 P720 60 WIDTh CHANnel x Space HIGH LOW IN OUT DONTcare CONDition Space TRUE FALSe TIME x Space OUT BETWeen TIMeout WINDow Space OFF ON NR...

Page 139: ...OUNt Function Sets queries the number of times the pattern for the A B n trigger should become true Syntax TRIGger ABN COUNt NRf TRIGger ABN COUNt NRf 1 to 100000000 Example TRIGGER ABN COUNT 1 TRIGGE...

Page 140: ...ns to 5 s Example TRIGGER ADB DELAY 1NS TRIGGER ADB DELAY TRIGGER ADB DELAY 1 0E 09 TRIGger ATRigger Function Queries all the pattern A settings Syntax TRIGger ATRigger Example TRIGGER ATRIGGER TRIGG...

Page 141: ...EL1 RISE Description Select from IN OUT when TRIGger OR WINDow ON is specified and from FALL RISE otherwise TRIGger OR WINDow Function Turns the OR trigger window ON OFF or queries the current setting...

Page 142: ...TRIGger SIMPle HFRejection OFF Frequency TRIGger SIMPle HFRejection Frequency 20 MHz 15 kHz Example TRIGGER SIMPLE HFREJECTION 20MHz TRIGGER SIMPLE HFREJECTION TRIGGER SIMPLE HFREJECTION 20 0E 06 Des...

Page 143: ...RCE CHANNEL1 TRIGGER SOURCE CHANNEL1 LEVEL 0 0E 00 COUPLING DC HFREJECTION OFF HYSTERESIS LOW CENTER 0 0E 00 WIDTH 2 000E 00 TRIGger SOURce CHANnel x COUPling Function Sets the trigger coupling of eac...

Page 144: ...s the current setting Syntax TRIGger TV LINE NRf TRIGger TV LINE NRf 5 to 1054 for NTSC 2 to 1251 for PAL or SECam 2 to 2251 other than NTSC PAL or SECam 8 to 2251 for 480 60P Example TRIGGER TV LINE...

Page 145: ...DTh TLINkage Function Turns the link ON OFF when changing the pulse width for the pulse width trigger or queries the current setting Syntax TRIGger WIDTh TLINkage Boolean TRIGger WIDTh TLINkage Exampl...

Page 146: ...RMat Space ASCii BYTE WORD LENGth OFFSet RANGe RECord RECord Space MINimum NRf SEND SIGN SRATe STARt Space NRf Space NRf TRACe Space NRf MATH x TRIGger TYPE MINimum WAVeform Function Queries all infor...

Page 147: ...form LENGth Function Queries the number of records total number of data points in the waveform designated by WAVeform TRACe Syntax WAVeform LENGth Example WAVEFORM LENGTH WAVEFORM LENGTH 1002 WAVeform...

Page 148: ...e record number specified by the WAVeform RECord command NRf in order WAVeform SIGN Function Queries the presence of the sign when querying the waveform specified with WAVeform TRACe in binary data fo...

Page 149: ...XAXIS SINGLE DISPLAY 1 TRANGE 5 00 5 00 XTRACE 1 TLINKAGE 0 YTRACE 2 XY x DISPlay Function Sets whether or not to display the X Y waveform or queries the current setting Syntax XY x DISPlay Boolean X...

Page 150: ...tion Sets the channel that is to be assigned to the X axis in the X Y display or queries the current setting Syntax XY x XTRace NRf MATH x XY x XTRace x of XY x 1 or 2 1 on the DL1720E x of MATH x 1 o...

Page 151: ...OOM key on the front panel ZOOM ALLOcation ALL Space OFF ON NRf CHANnel x Space OFF ON NRf MATH x Space OFF ON NRf FITMeasure Space Z1 Z2 FORMat Space MAIN SINGle DUAL TRIad QU AD HEXa MLINkage Space...

Page 152: ...MEAURE Z1 ZOOM FITMEAURE ZOOM FITMEAURE Z1 ZOOM FORMat Function Sets queries the zoom display format Syntax ZOOM FORMat MAIN SINGle DUAL TRIad QUAD HEXa ZOOM FORMat Example ZOOM FORMAT SINGLE ZOOM FOR...

Page 153: ...Example CLS Description The output queue will also be cleared if a CLS command is appended after the program message terminator For details of the registers and queue refer to Chapter 6 ESE standard E...

Page 154: ...E MODE 0 AVALUE 1 00000E 00 BVALUE 0 00000E 00 UNIT CHANNEL3 LABEL CH3 CHANNEL4 DISPLAY 1 VDIV 50 000E 00 POSITION 0 00 COUPLING DC PROBE 10 OFFSET 0 0E 00 BWIDTH FULL VARIABLE 50 000E 00 LSCALE MODE...

Page 155: ...ires about the current setting Syntax SRE NRf SRE NRf 0 to 255 Example SRE 239 SRE 239 Description NRf is the sum of the bits expressed as a decimal number For example if ESE 239 is set the service re...

Page 156: ...12 11 10 9 8 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Condition Filter Transit Filter Extended Event Register 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0...

Page 157: ...ESE query is used to check whether bits in that register are set to 1 or 0 For details of these commands refer to Chapter 5 6 2 Status Byte Overview of Status Byte 7 6 ESBMAVEES EAV 1 0 RQS MSS Bits 0...

Page 158: ...n the status byte are cleared except bit 4 MAV since the output queue cannot be emptied by the CLS command However the output queue will also be cleared if the CLS command is received just after a pro...

Page 159: ...MES 7 5 4 3 2 1 0 PRN TST CAL TRG HLD RUN HST 8 SUP 9 NGO 10 SCH 11 NSG 12 INI 13 FFT 14 0 15 6 7 5 4 3 2 1 0 8 9 10 11 12 13 14 15 Condition Register STATus CONDition Transition Filter 0 14 15 Exten...

Page 160: ...ored record by record in the output queue and is read out oldest item first newest item last The output queue is emptied in the following cases in addition to when read out is performed When a new mes...

Page 161: ...rface Conforms to USB Rev 1 0 Setting up the Visual Basic Standardmodule tmctl bas tmval bas Setting up the DL1720E DL1740E DL1740EL GP IB All the sample programs given in this chapter use address 1 f...

Page 162: ...7 2 IM 701730 17E 7 2 Image of Sample Program 7 2 Image of Sample Program...

Page 163: ...ot Terminator LF EOI Enable If sts CTL_OK Then Call DisplayError Dev InitGpib 1 GoTo PostProcces End If sts TmSetTimeout Dev timeout Timeout 10s If sts CTL_OK Then Call DisplayError Dev InitGpib 1 GoT...

Page 164: ...8192 Then ers Illegal device ID Else ers End If MsgBox Error No Str err Chr 13 ers vbExclamation Error End Sub Private Sub Command1_Click Dim sts As Long If StartFlag 1 Then Exit Sub End If StartFlag...

Page 165: ..._Click Dim sts As Long If StartFlag 1 Then Exit Sub End If StartFlag 1 Text1 Text START List1 Clear sts UsbGetWord Run Sample5 USB Get Word Data If sts 0 Then List1 AddItem END End If Text1 Text END S...

Page 166: ...UsbTdiv 1 GoTo UsbTdivEnd End If UsbTdiv 0 UsbTdivEnd Call CloseDevice Device Close End Function Private Function GetTdiv As Long Dim msg As String Command buffer Dim qry As String Query biffer Dim st...

Page 167: ...Sample Program 7 7 IM 701730 17E 7 GP IB USB 7 4 Sets Queries the T Div...

Page 168: ...nd If UsbGetWord 0 UsbGetWordEnd Call CloseDevice Device Close End Function Private Function GetWord As Long Dim msg As String Command buffer Dim qry As String Query biffer Dim sts As Long Dim vdv As...

Page 169: ...End If sts TmReceive Dev qry Len qry rlen If sts CTL_OK Then Call DisplayError Dev GetWord 1 Exit Function End If vdv Val qry msg WAVEFORM OFFSET Get Offset value sts TmSend Dev msg If sts CTL_OK Then...

Page 170: ...30 17E msg COMMUNICATE HEADER ON Query Header On sts TmSend Dev msg If sts CTL_OK Then Call DisplayError Dev GetWord 1 Exit Function End If GetWord 0 End Function GP IB USB 7 5 Data Output in Word For...

Page 171: ...1 Exit Function End If msg COMMUNICATE HEADER OFF Query Header Off for Get V div sts TmSend Dev msg If sts CTL_OK Then Call DisplayError Dev GetMeasure 1 Exit Function End If msg MEASURE MODE OFF Meas...

Page 172: ...v GetMeasure 1 Exit Function End If msg MEASURE TRANGE 5 5 Measure Time Range 5 5 sts TmSend Dev msg If sts CTL_OK Then Call DisplayError Dev GetMeasure 1 Exit Function End If msg SSTART 500 Start Sin...

Page 173: ...1 Exit Function End If sts TmReceive Dev qry Len qry rlen If sts CTL_OK Then Call DisplayError Dev GetMeasure 1 Exit Function End If Query 1 Average Left qry rlen 1 msg MEASURE CHANNEL1 FREQUENCY VAL...

Page 174: ...70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53...

Page 175: ...ge Check the header Chapter 5 120 Numeric data error Numeric value must be entered for NRf format 4 5 123 Exponent too large Use a smaller exponent for NR3 format 4 5 Chapter 5 124 Too many digits Lim...

Page 176: ...88 2 278 Macro header not found Does not conform to the macro function specified in IEEE488 2 Error in Communications Query 400 to 499 Code Message Action Reference Page 410 Query INTERRUPTED Check tr...

Page 177: ...urn Multiple Response Messages Refer to Chapter 5 Command List c Queries which Generate Response Data during Analysis of the Syntax Every query generates a response data when analysis of the syntax is...

Page 178: ...Size of Storage Area for Protected User Data for PUD and PUD PUD and PUD are not supported 18 Length of RDT and RDT Resource Name RDT and RDT are not supported 19 Change in Status Due to RST LRN RCL...

Page 179: ...ured Results P P PTOPeak P P Max MAXimum Max Min MINimum Min Avg AVERage Avg Rms RMS Rms Sdev SDEViation SDv High HIGH High Low LOW Low OShot POVershoot Ovr OShot NOVershoot Ovr Freq FREQuency Freq Pe...

Page 180: ...tus 5 88 current setting 5 119 current to voltage conversion ratio 5 21 cursor X Y display 5 30 CURSor Group 5 25 cursor measurement 5 27 cycle statistics 5 75 D data 4 1 4 5 data saving 5 42 data tra...

Page 181: ...roup 5 79 print external printer 5 53 print of screen image data 5 53 print operation 5 53 probe 5 107 probe attenuation 5 21 program message 4 1 program message unit 4 1 pulse width search 5 90 pulse...

Page 182: ...zoomed waveform 5 117 Command List ACQuire Group ACQuire 5 16 AVERage COUNt 5 16 AVERage EWEight 5 16 AVERage 5 16 CLOCk 5 16 COUNt 5 16 INTerleave 5 16 MODE 5 16 REPetitive 5 16 RLENgth 5 16 ASETup G...

Page 183: ...RGB MENU BACK DIALog FOCus FORE LINE SELect SHADow 5 35 RGB MENU 5 35 RGB OTHers CURSor GRID MARKer SNAP ZONE x 5 36 RGB OTHers 5 35 RGB WAVeform 5 36 RGB 5 35 SMAPping CHANnel x MATH x 5 37 SMAPping...

Page 184: ...5 59 ZONE LOGic 5 59 ZONE 5 59 IMAGe Group ABORt 5 61 COMMent 5 61 COMPression 5 61 EXECute 5 61 FORMat 5 61 IMAGe 5 61 SAVE ANAMing 5 61 SAVE CDIRectory 5 61 SAVE DRIVe 5 61 SAVE NAME 5 61 SAVE 5 61...

Page 185: ...8 PPATtern CHANnel x MATH x PATTern 5 88 PPATtern CHANnel x MATH x 5 87 PPATtern CLOCk HYSYeresis 5 88 PPATtern CLOCk LEVel 5 88 PPATtern CLOCk SLOPe 5 88 PPATtern CLOCk SOURce 5 88 PPATtern CLOCk 5 8...

Page 186: ...Rejection 5 108 SOURce CHANnel x HYSTeresis 5 108 SOURce CHANnel x LEVel 5 108 SOURce CHANnel x WIDTh 5 109 SOURce CHANnel x 5 108 SOURce 5 108 TRIGger 5 104 TV FIELd 5 109 TV FRAMe 5 109 TV LEVel 5 1...

Reviews: