YOKOGAWA CX1000 Installation And Connection Manual Download Page 2

Arrangement of the Control Input/Output Terminals
on the CX1206 and CX1200

Analog Control Input / Measurement Input 
Terminal Block

Input termials for the loops 1 and 2, 
and measurement terminals. 

Control Output Terminal Block

Output termials for the loops 1 and 2.

1

1

0

0

and : 

Terminal 

block 

number

Character Indicating the type 

of input/output signal

Terminal number

005

A

+

No screw terminal is attached.

For the maintenance use only. 

Do not wire.

Symbols

C

: Common

NO

: Normally Opened

NC

: Normally Closed

mA

: Current output

PULSE

: Voltage pulse output

Control Output Terminal (Terminal Block: 0)

Installed on the CX1206 and CX1200.

Contact 

input

Transistor

output

Control current/

voltage pulse output

relay contact 

output

LOOP1

LOOP2

1

Control relay 

contact output

LOOP1

LOOP2

2

025

026

027

028

029

030

022

023

019

020

016

017

018

013

014

015

010

011

012

007

008

009

004

005

006

4

5

6

3

4

C

5

6

C

mA

PULSE

C

mA

PULSE

C

NO

C

NO

C

NO

NC

C

NO

NC

C

1

2

3

001

002

003

Analog Control Input / Measurement Input Terminal  (Terminal
Block: 1)

Installed on the CX1206.

LOOP1

LOOP2

128

129

130

b

A

+

B

131

132

133

b

A

+

B

125

126

127

b

A

+

B

122

123

124

b

A

+

B

119

120

121

b

A

+

B

116

117

118

b

A

+

B

113

114

115

b

A

+

B

110

111

112

b

A

+

B

107

108

109

b

A

+

B

104

105

106

b

A

+

B

101

102

103

b

A

+

B

1

2

4

5

6

3

Channel number (Measurement input terminal)

PV

(RSP)

PV

(RSP)

PV

(RSP)

PV

PV1

PV2

PV1

PV2

(RSP)

During single loop control
During cascade control
During loop control with PV switching
[Control mode setting]

Analog Control Input Terminal (Terminal Block: 1)

Installed on the CX1200.

LOOP1

LOOP2

128

129

130

b

A

+

B

131

132

133

b

A

+

B

125

126

127

b

A

+

B

122

123

124

b

A

+

B

119

120

121

b

A

+

B

PV

(RSP)

PV

(RSP)

PV

(RSP)

PV

PV1

PV2

PV1

PV2

(RSP)

During single loop control
During cascade control
During loop control with PV switching
[Control mode setting]

Arrangement of the Measurement Input/Output
Terminals  on the CX1006 and CX1000

Measurement Input Terminal Block

Measurement input terminals

Measurement Alarm Option Terminal Block

Installed when you specified /A6, /A6R, /A4F, or 
/A4FR at the time of purchase.

1

1

0

0

and : 

Terminal 

block 

number

Measurement Alarm Option Terminal (Terminal Block: 0)

The measurement alarm option terminal block is the terminal block that you
specified as an option to the CX1006 or CX1000 at the time of purchase. The
following four types are available.
/ A6

Alarm output

025

026

027

028

029

030

019

020

010

011

012

NC

C

NO

NC

C

NC

C

NO

021

NO

NC

C

NO

016

017

018

NC

C

NO

06

05

04

03

02

01

034

035

036

NC

C

NO

/ A6R

Measurement remote input

Alarm output

025

026

027

028

029

030

019

020

010

011

012

007

008

009

004

005

006

3

4

5

6

7

8

NC

C

NO

NC

C

NC

C

NO

021

NO

NC

C

NO

016

017

018

NC

C

NO

06

05

04

03

02

01

034

035

036

NC

C

NO

C

1

2

001

002

003

/ A4F

FAIL 

output

Memory end 

output

Alarm output

025

026

027

028

029

030

019

020

010

011

012

NC

C

NO

NC

C

NC

C

NO

021

NO

NC

C

NO

016

017

018

NC

C

NO

04

03

02

01

034

035

036

NC

C

NO

/ A4FR

Measurement remote input

FAIL 

output

Memory end 

output

Alarm output

025

026

027

028

029

030

019

020

010

011

012

007

008

009

004

005

006

3

4

5

6

7

8

NC

C

NO

NC

C

NC

C

NO

021

NO

NC

C

NO

016

017

018

NC

C

NO

04

03

02

01

034

035

036

NC

C

NO

C

1

2

001

002

003

Measurement Input Terminal (Terminal Block: 1)

Installed on the CX1006.

116

117

118

b

A

+

B

113

114

115

b

A

+

B

110

111

112

b

A

+

B

107

108

109

b

A

+

B

104

105

106

b

A

+

B

101

102

103

b

A

+

B

Channel number (Measurement input terminal)

1

2

4

5

6

3

Input Wiring

Measurement Input Wiring

Lead wire resistance
per wire of 10 

 

or less.

Make the resistance of
the three wires equal.

A

b

B

b

A

B

b

A

B

b

A

B

b

A

B

• Thermocouple input

Compensation lead

• RTD input

DC voltage input

• DC voltage input

DC current input

Shunt resistor
Example: For 4 to 20 mA input,
shut resistance values should be
250 

 ±

0.1%.

• DC current input

+

+

Contact Input (DIGITAL IN) Wiring

2

1

4

6

3

5

C

1

2

3

4

5

6

C

• Relay contact input

• Transistor input

Relay Contact Input/Transistor Input

Input signal: no-voltage contact, open collector
Input condition: ON voltage, under 0.5 V (30 mADC); OFF voltage, leakage
current under 0.25 mA
Input format: photocoupler isolation (common)
Withstand voltage: 500 VDC, 1 min (between input terminal and earth)

Measurement Alarm Option Terminal Block Contact Input
(REMOTE) Wiring

C

1

2

3

4

5

6

7

8

C

1

2

3

4

5

6

7

8

• Relay contact input

• Transistor input

Relay Contact Input/Transistor Input

See “Relay Contact Input (DIGITAL IN) Wiring.”

Output Wiring

Control Output (LOOP1 and 2) Wiring

C

mA

C

PULS

+

4 to 20 mADC or
0 to 20 mADC

• 

Voltage pulse output

• 

Current output

Voltage pulse (12 V)

+

NC

C

NO

• Relay contact output

250 VAC, 3 A or
30 VDC, 3 A
(resistive load)

(when set to energized)

Current Output

Output signal: 4 to 20 mADC or 0 to 20 mADC
Resistive load: 600 

 or less

Voltage Pulse Output

Output signal: ON voltage=12 VDC
Resistive load: 600 

 or more

Relay Contact Output

Output signal: NC, NO, COM
Contact rating: 250 VAC (50/60 Hz)/3 A or 30 VDC/3 A (resistive load)

Contact Output (DIGITAL OUT) Wiring

C

6

5

4

3

C

NO

• Relay contact output of the control output terminal block

250 VAC, 1 A or
30 VDC, 1 A (resistive load)

• Transistor output of the control output terminal block

24 VDC/50 mA

C

3 to 6

 +

Pull-up resistor

 Connection example 

for a transistor output

Relay Output

Output form: relay contact
Contact rating: 250 VAC (50/60 Hz)/1 A or 30 VDC/1 A (resistive load)

Transistor Output

Output method: open collector output
Contact rating: 24 VDC/50 mA
A label indicating the terminal arrangement is affixed to the front and back
of the terminal cover of each terminal block.

Measurement Alarm Option Terminal Block Contact Output
(ALARM, FAIL, MEMORY) Wiring

C

NO

NC

250 VAC/3A, 
250 VDC/0.1 A(resistive load)

Relay Output

Output form: relay contact
Contact rating: 250 VAC (50/60 Hz)/1 A or 250 VDC/0.1 A (resistive load)

Label on the Back (For the  Analog Control Input / Measurement Input Terminal Block)

Label on the Front (For the Analog Control Output Terminal Block)

Terminal 
symbol

+

A

-

B

5

+

A

-

B

4

+

A

-

B

3

+

A

-

B

2

+

A

-

B

1

PV

PV

SNGL

PV

PV

CAS

PV1

PV1

PV2

PV2

PVSW

1

3

1

2

2

LOOP 2

CAT II

!

LOOP 1

RSP

(       )

RSP

(       )

RSP

(       )

RSP

(       )

+

A

-

B

6

b

b

b

b

b

b

CAT

DIGITAL-IN

004

005

006

001

002

003

007

008

009

010

011

012

013

014

015

016

017

018

019

020

022

023

025

026

027

028

029

030

DIGITAL-OUT

CTRL-OUT

DIGITAL-OUT

CTRL-OUT

During single-loop control

During cascade control

During loop control with PV switching

[Control mode setting]

Label on the Front of the Terminal Cover

The terminal numbers are written on the label on the front of the terminal cover. Terminal numbers are 
unique three-digit numbers. They are used to locate terminals on the wiring diagram, etc. The highest 
digit indicates the arrangement position of the terminal block; the lower two digits indicate the terminal 
position within the terminal block (top right terminal is assigned "01" bottom left terminal is assigned 
"36"). The terminals that cannot be used are indicated as "    ".

PV, PV1, PV2: PV input, (RSP): RSP input(not used during program control),    : unused terminal

Label on the Back of the Terminal Cover

Indicates the type of input/output signals for each terminal. 
You can select the control modes from "single loop control", "cascade control", and "loop control with 
PV switching" on the CX. The arrangement of the analog control input (PV) terminals are changed 
depending on the control mode selected. The terminal arrangement for these three control modes are 
written on the label on 

Analog Control Input Terminal

Reviews: