IM CL360
13
Analogue Output (Output impedance: Approx. 1k
Ω
)
AC Output
Range
Measuring range
AC Output Voltage
Accuracy
200mA 0
to
200mA
2A 0
to
2A
20A 0
to
20A
±2.0% rdg
200A 0
to
200A
0 to 200mV
±2.5% rdg
0 to 500A
0 to 50mV
±3.0% rdg
1000A
501 to 1000A
50 to 100mV
±5.0% rdg
Voltage proportional to the current under test is output with “WIDE” frequency
characteristics regardless of the setting of the frequency selector or peak hold switch.
DC Output
Accuracy (Frequency Range)
Range Measuring range
DC Output
Voltage
Freq. Selector
Switch at WIDE
position
Freq. Selector
Switch at 50/60Hz
position
200mA 0
to
200mA
2A 0
to
2A
20A 0
to
20A
±3.0% rdg
±3.5% rdg
200A 0
to
200A
0 to 200mV
±3.5% rdg
±4.0% rdg
0 to 500A
0 to 50mV
±5.0% rdg
±5.5% rdg
1000A
501 to 1000A
50 to 100mV ±7.0% rdg
±7.5% rdg
General Specifications
●
Operating System : Dual integration
●
Measurement Function : AC current
●
Display : Field effect 3 - 1/2 digit liquid crystal display with maximum count
of 1999
●
Range selection : Manual
●
Overrange Indication : "1" is displayed on the highest digit except for
1000A AC range.
●
Response Time : Approx. 1 seconds.
●
Sample Rate : Approx. 3 times per second.
●
Temperature and Humidity for Guaranteed Accuracy : 23°C ±10°C, relative
humidity up to 85% without condensation
●
Operating Temperature and Humidity : 0 to 40°C, relative humidity up to
85% without condensation
14
IM CL360
●
Storage Temperature and Humidity : -10 to 50°C, relative humidity up to
80% without condensation
●
Effect of conductor position: Within 2% difference between maximum and
minimum values to a 10 mm-dia conductor, at every part inside the jaws
●
Effect of External Magnetic Field :
15mA AC max. in proximity to a 10mm-dia conductor carrying 100A AC.
●
Effect of Residual Current : 10mA AC max. when clamping on two
10mm-dia conductors, each carrying supply or return 100A AC current.
●
Power Source : 6LR61 or 6F22 DC9V battery
●
Battery Life : Approx. 60 hours (continuity)
●
Current Consumption : Approx. 5mA max.
●
Withstanding Voltage : 3700V AC, 50/60Hz for 1 minute between electrical
circuit and housing case or metal part of the jaws
●
Insulation Resistance : 10M
Ω
or greater at 1000V between electrical circuit
and housing case or metal part of the jaws
●
Conductor Size : Approx. 68mm diameter max.
●
Dimensions : Approx.130(W) x 250(H) x 50(D) mm
●
Weight : Approx. 570g
●
Safety Standard: EN 61010-1
EN
61010-2-032
AC 300V CAT III, AC 600V CAT II,
Pollution degree 2, indoor use
●
EMC Standard: EN 61326
EN
55022
●
Accessories : 6F22 battery······························ 1
Carrying case Model 93031 ······ 1
User’s Manual ··························· 1
●
Optional Accessories : Output cable with banana plug Model 91020
●
Peak Hold : Response time selectable from approx. 10ms and 100ms.
1/
2
of the peak current is displayed, which means an RMS reading will
be obtained when current having sinusoidal waveform in measured.
Peak hold reading varies by approximately ±1% max of full scale in the
first minute at 23°C ±10°C and relative humidity of 75% without condensa-
tion.
IM CL360
15
5. Calibration and After-sales Service
Should any failure occur while you are using the tester, follow the instructions
given below. If the tester still fails to operate correctly and needs repair, con-
tact the vendor from whom you purchased the instrument or the nearest
Yokogawa M&C sales office.
Condition Possible
Cause
Remedy
Display blanks after
power-on
Battery is improperly installed.
Battery is exhausted.
Install the battery correctly.
Replace the buttery.
Display reading
remains frozen.
Data hold button is pressed in.
Peak hold switch is at ON
position.
Release data hold button.
Set peak hold switch to OFF
position.
Transformer jaws buzz
when measuring large
current.
-----------------
This is not a failure
The lowest digit of
reading is unstable
-----------------
This is not a failure. The
instrument is highly accu-
rate, so it senses slight
variations in the current
under test.
Output cable
(Model 91020) does not
output voltage.
The cable is open circuit.
Check the cable for an open
circuit.
Calibration
It is recommended that the instrument be calibrated once every year.