YOKOGAWA BA10 Instruction Manual Download Page 3

IM12B06W02-01EN-P

3

1. PREFACE

1.1 Introduction

Between measuring plant and control 
room, especially when the distance 
between these places is greater than 
the length of the standard appropriate 
sensor cables, the BA10 connecting
equipment can be an expedient method 
for connecting sensor cables to an 
extension cable which is connected to 
the measuring device. Although BA10 
enables longer distance connection it is 
not advisable to use it in pH measuring 
loops. For pH loops with long distance 
cable runs it is recommended to use 

digital Sencom configuration.

1.2 Unpacking and Checking 

Upon arrival of the purchased product, 
carefully unpack it and make sure the 
product has not been damaged during 
transportation.

Verify the model code on a name label 
adhered on the packaging box. For de-
tails of the model code, see subsection 6.

1.3 Warranty and Service

 

Yokogawa products and parts are guar-
anteed free from defects in workman-
ship and material under normal use 
and service for a period of (typically) 12 
months from the date of shipment from 
the manufacturer. Individual sales or-
ganizations can deviate from the typical 
warranty period, and the conditions of 
sale relating to the original purchase 
order should be consulted. Damage 
caused by wear and tear, inadequate 

maintenance, corrosion, or by the effects 

of chemical processes are excluded from 
this warranty coverage. In the event 
of warranty claim, the defective goods 
should be sent (freight paid) to the 
Service Department of the relevant sales 
Organization for repair or replacement 
(at Yokogawa’s discretion)

The following information must be 
included in the letter accompanying the 
returned goods: 

•  Model Code and Serial Number. 
•  Original Purchase Order and Date. 
•  Length of time in service and descrip-
tion of the process. 
•  Description of the fault and circum-
stances of the failure. 
•  Process/environmental conditions 
that may be related to the failure of the 
connection box
•  Statement as to whether warranty or 
non-warranty service is requested. 
•  Complete shipping and billing instruc-
tions for return of material, plus the 
name and phone number of a contact 
person that can be reached for further 
information.
•  Clean Statement 
   Returned goods that have been in 

contact with process fluids must be 

decontaminated and disinfected prior 
to shipment. Goods should carry a cer-

tificate to this effect, for the health and 

safety of our employees. Material Safety 
Data sheets must be included for all 
components of the process to which the 
connection box has been exposed. 

Summary of Contents for BA10

Page 1: ...Instruction Manual Model BA10 Junction box IM12B06W02 01EN P 1st edition ...

Page 2: ...g and Checking 3 1 3 Warranty and Service 3 1 4 Serial number 4 2 GENERAL SPECIFICATIONS 5 2 1 Junction box type BA10 5 2 2 Specifications 5 2 3 Shipping details 5 3 INSTALLATION 6 4 DIMENSIONS 7 5 WIRING 7 6 MODEL AND SUFFIX CODES 8 2 IM12B06W02 01EN P ...

Page 3: ...ons of sale relating to the original purchase order should be consulted Damage caused by wear and tear inadequate maintenance corrosion or by the effects of chemical processes are excluded from this warranty coverage In the event of warranty claim the defective goods should be sent freight paid to the Service Department of the relevant sales Organization for repair or replacement at Yokogawa s dis...

Page 4: ...uction Year code Year Year code Year Year code 2014 P 2026 3 2015 R 2027 4 2016 S 2028 5 2017 T 2029 6 2018 U 2030 7 2019 V 2031 8 2020 W 2032 9 2021 X 2033 A 2022 Y 2034 B 2023 Z 2035 C 2024 1 2036 D 2025 2 2037 E Month Month code January 1 February 2 March 3 April 4 May 5 June 6 July 7 August 8 September 9 October A November B December C Table 2 Production Month code 4 IM12B06W02 01EN P ...

Page 5: ...s Material Cast aluminium case with chemically resistant coating Rain and dust protection Meets IP 65 Terminals Screw type wires up to 6 mm2 Cable entries 2 holes with screw thread Weight Ca 2 kg Dimensions See Fig 6 dimensional drawing Fixing 140 x 110 mm indicated on reverse side of the box Note As delivered the box includes 2 cable glands PG 16 Figure 3 a hose connection for a 19 mm I D protect...

Page 6: ...ALLATION BA10 Figure 3 PG16 cable glands Figure 5 Grommet Figure 4 Hose connector for 19mm I D protection hose IM12B06W02 01EN P 6 Figure 1 BA10 junction box Figure 2 PG16 cable gland and grounding connection ...

Page 7: ...ENSIONS Figure 6 Dimensions BA10 in mm 5 WIRING BA10 wiring Figure 8 Example of connection diagram 1 Note 1 For details on connection please refer to respective analyzer sensor Instruc tion manual Figure 7 BA10 connection block ...

Page 8: ...Subject to change without notice Copyright Printed in The Netherlands 01 2201 IM12B06W02 01EN P 6 MODEL AND SUFFIX CODES Table 3 MS Code Model Suffix code Description BA10 Terminal box for normal use ...

Reviews: