4-9
IM AQ7277-17EN
Commands
:ACQuire:SELection:DRANge?
Function Queris the selectable distance range.
Syntax
:ACQuire:SELection:DRANge?
Sample
:ACQUIRE:SELECTION:DRANGE? ->
:ACQUIRE:SELECTION:DRANGE 500,
1000, … ,4000000
Description The value that you can
specify varies depending on the
wavelength setting.
The selectable distance range varies
depending on the wavelength.
Setting the distance range
Auto: AUTO
500m: 500
1km: 1000
2km: 2000
5km: 5000
10km: 10000
20km: 20000
50km: 50000
100km: 100000
200km: 200000
300km: 300000
400km: 400000
:ACQuire:SELection:WAVelength?
Function Queris the selectable measured wavelength.
Syntax
:ACQuire:SELection:WAVelength?
Sample
:ACQUIRE:SELECTION:WAVELENGTH? ->
:ACQUIRE:SELECTION:WAVELENGTH
1.310E-6.1.550E-6
:ACQuire:SELection:PWIDth?
Function Queris the selectable pulse width.
Syntax
:ACQuire:SELection:PWIDth?
Sample
:ACQUIRE:SELECTION:PWIDTH? ->
:ACQUIRE:SELECTION:PWIDTH
3E-9.10E-9, … , 20E-6
:ACQuire:SELection:ATTenuation?
Function Queris the selectable attenuatio.
Syntax
:ACQuire:SELection:ATTenuation?
Sample
:ACQUIRE:SELECTION:ATTENUATION? ->
:ACQUIRE:SELECTION:ATTENUATION
0.00,2.50,5.00, …, 27.50
:ACQuire:SELection:SMPinterval?
Function Queris the selectable sampling interval.
Syntax
:ACQuire:SELection:SMPInterval?
Sample
:ACQUIRE:SELECTION:SMPINTERVAL? ->
:ACQUIRE:SELECTION:SMPINTERVAL
0.05,0.10,0.20,…,4.00
ANALysis Group
The commands in this group deal with waveform analysis.
:ANALysis:ASEarch:EXECute
Function Executes auto detection.
Syntax
:ANALysis:ASEarch:EXECute
Example
:ANALysis:ASEarch:EXECute
:ANALysis:ASEarch:NUMber?
Function Queries the number of auto detection events.
Syntax
:ANALysis:ASEarch:NUMber?
Example
:ANALysis:ASEarch:NUMber? ->
:ANAL:ASE:NUM 2
:ANALysis:BCOefficient
Function Sets the backscattering light level of the current
wavelength or queries the current setting.
Syntax
:ANALysis:BCOefficient {<NRf>}
:ANALysis:BCOefficient?
<NRf> = -10.00 to -64.99
(steps of 0.01)
Example
:ANALysis:BCOefficient -25.00
:ANALysis:BCOefficient? ->
:ANAL:BCO -50.00
:ANALysis:IOR
Function Sets the group refraction index of the current
wavelength or queries the current setting.
Syntax
:ANALysis:IOR {<NRf>}
:ANALysis:IOR?
<NRf> = 1.30000 to 1.79999
(steps of 0.00001)
Example
:ANALysis:IOR 1.48000
:ANALysis:IOR? -> :ANAL:GIND 1.48000
:ANALysis:CURSor:DELete
Function Clears the cursor.
Syntax
:ANALysis:CURSor:DELete
Example
:ANALysis:CURSor:DELete
:ANALysis:CURSor:DISTance
Function Sets the cursor position or queries the current
setting.
Syntax
:ANALysis:CURSor:DISTance {<NRf>}
:ANALysis:CURSor:DISTance?
<NRf> = Depend on distance range,
distance reference and IOR.
Example
:ANALysis:CURSor:DISTance 10.00
:ANALysis:CURSor:DISTance? ->
:ANAL:CURS:DIST 11.00
Description Depending on the distance range, distance
reference and group refraction.
4.3 Device-Specific Commands
1
2
3
4
5
App
Index