2-inch Pipe Mounting
2-inch pipe
Mounting fixture
Washer
Clamp screw
F0328.ai
Figure 3.4.4 2-inch Pipe Mounting
1. Pass the four clamp screws through the mounting
fixture.
2. position it on the 2-inch pipe, and then fasten the
AXG1A in place.
Panel Mounting
Panel cutout
172 (6.8)
R3MAX
Mounting fixture
Unit: mm
(approx. inch)
Washer
Screw
Clamp screw
203 (8.0)
F0329.ai
Figure 3.4.5 Panel Mounting
1. Fit the AXG1A into the panel.
2. Attach the mounting fixture to the AXG1A using the
screw and the washer, and secure the product with
the two clamp screws.
3.4.4 Mounting of AXFA11 Transmitter
AXFA11 Remote Transmitter can be mounted using
surface mounting, 2-inch pipe mounting, or panel
mounting, by the same process of AXG1A. Please refer
3.4.3. for the process.
IMPORTANT
Mounting fixture on equipment intended to be mounted
on a wall or ceiling shall withstand a force of four times
the weight of the equipment (AXFA11: 3.4 kg (7.5 lb)).
3.5 Changing Direction of
Cable Entry
IMPORTANT
The following types can not be changed direction of
cable entry after delivery.
• Submersible Type (Suffix code: -W)
• For District Heating and Cooling or Condensation-
proof (Optional code: DHC)
(1) The following tool is required.
• Hexagonal wrench (nominal size 5)
(2) Turn off the power to the flowmeter.
(3) Using the wrench, unscrew the four hexagonal bolts
at the neck of transmitter or terminal box.
F0330.ai
AXW Remote Sensor
AXW Integral Flowmeter
Transmitter
Terminal box
CAUTION
Do not loosen the screw at the opposite side of cable
entry (see the figure below).
F0331.ai
<3. Installation>
26
IM 01E24A01-01EN