background image

User's

Manual

Notes

•  The contents of this manual are subject to change without prior notice as a result of continuing 

improvements to the product’s performance and functionality. The figures given in this manual may 

differ from those that actually appear on your product.

•  Every effort has been made in the preparation of this manual to ensure the accuracy of its 

contents. However, should you have any questions or find any errors, please contact your nearest 

YOKOGAWA dealer.

•  Copying or reproducing all or any part of the contents of this manual without the permission of 

YOKOGAWA is strictly prohibited.

Conventions Used in This Manual

 

Improper handling or use can lead to injury to the user or damage to the instrument. 

This symbol appears on the instrument to indicate that the user must refer to the 

user’s manual for special instructions. The same symbol appears in the corresponding 

place in the user’s manual to identify those instructions. In the manual, the symbol is 

used in conjunction with the word “WARNING” or “CAUTION.”

 WARNING 

Calls attention to actions or conditions that could cause serious or fatal injury to the 

user, and precautions that can be taken to prevent such occurrences.

 CAUTION 

Calls attention to actions or conditions that could cause light injury to the user or 

cause damage to the instrument or user’s data, and precautions that can be taken to 

prevent such occurrences.

Note 

Calls attention to information that is important for the proper operation of the instrument.

French

 

Une manipulation ou une utilisation incorrectes risquent de blesser l’utilisateur ou 

d’endommager l’instrument. Ce symbole apparaît sur l’instrument pour indiquer 

à l’utilisateur qu’il doit se reporter au manuel de l’utilisateur afin d’y lire les 

instructions spécifiques correspondantes. Ce même symbole apparaît à la section 

correspondante du manuel de l’utilisateur pour signaler lesdites instructions. Dans le 

manuel de l’utilisateur, ce symbole est accompagné des termes AVERTISSEMENT et 

ATTENTION.

 AVERTISSEMENT 

Attire l’attention sur des gestes ou des conditions susceptibles de provoquer 

des blessures graves (voire mortelles), et sur les précautions de sécurité 

pouvant prévenir de tels accidents.

 ATTENTION 

Attire l’attention sur des gestes ou des conditions susceptibles de provoquer des 

blessures légères ou d’endommager l’instrument ou les données de l’utilisateur, et 

sur les précautions de sécurité susceptibles de prévenir de tels accidents.

Safety Precautions

This product is designed to be used by a person with specialized knowledge. To use this product 

correctly and safely, the general safety precautions described herein must be observed during all 

phases of operation. YOKOGAWA assumes no liability for the customer’s failure to comply with these 

requirements.

This manual is part of the product and contains important information. Keep this manual in a safe 

place so that you can refer to it immediately when using the product until you dispose of the product. In 

addition, before using the probe, read the manuals of the oscilloscope to thoroughly familiarize yourself 

with its specifications and operations.

The following symbols are used on this instrument.

  Handle with care. Refer to the user’s manual or service manual. This symbol appears on 

dangerous locations on the instrument which require special instructions for proper handling 

or use. The same symbol appears in the corresponding place in the manual to identify those 

instructions.

French

  À manipuler délicatement. Toujours se reporter aux manuels d’utilisation et d’entretien. Ce 

symbole a été apposé aux endroits dangereux de l’instrument pour lesquels des consignes 

spéciales d’utilisation ou de manipulation ont été émises. Le même symbole apparaît à l’endroit 

correspondant du manuel pour identifier les consignes qui s’y rapportent.

Notes about Usage

 WARNING

Purpose of the product

The product is used in combination with an oscilloscope to observe and measure electrical 

signals. Do not use for any other purpose.

Grounding of the measuring instrument

The protective grounding terminal of the oscilloscope must be connected to ground.

Grounding of the probe

Make sure to connect the ground lead or the equivalent accessory of the probe to the 

grounding potential.

Observe the maximum input voltage

Do not apply a voltage exceeding the maximum input voltage to the probe.

Be careful of electric shock

Never use the probe with wet hands or when the probe itself is wet. Doing so may cause 

electric shock. Be careful of electric shock when you connect the probe to the device under 

measurement.

Do not operate in wet or damp conditions

To prevent electric shock, do not operate the probe in wet or damp conditions.

Avoid exposed circuitry

To prevent electric shock, remove watches, rings or other metal jewelry. Do not touch 

exposed connections or components when power is present on the device.

Do not operate in explosive atmosphere

To prevent injury or fire hazard, do not operate the probe in an atmosphere of flammable or 

explosive gases or vapors.

Be careful of burns and frostbite

When the probe is connected to a device under measurement that is hot or cold, do not 

touch the probe directly. In such situations, the probe will also be hot or cold, and touching 

it may cause burns or frostbite. Also, be careful of burns and frostbite when you connect the 

probe to such device under measurement.

Do not operate with suspected failures

Stop using the probe if you suspect that the probe is damaged. Consult your nearest 

YOKOGAWA dealer.

Thank you for purchasing the Model 702906, 10:1 Passive Probe (Wide operating temperature range, 

for non-isolated BNC input). This user’s manual explains usage, specifications, and the handling 

precautions of the 702906. To ensure correct use, please read this manual thoroughly before beginning 

operation. After reading this manual, keep it in a safe place.

IM 702906-01EN

8th Edition

Do not operate with a damaged cable

Stop using the probe if the probe cable is torn and the inner metal is exposed or if a color 

different from the outer sheath appears.

Do not disassemble or modify

Do not disassemble or modify the product. YOKOGAWA assumes no liability if you 

disassemble or modify the product.

French

 AVERTISSEMENT

But du produit

Le produit est utilisé en association avec un oscilloscope pour observer et mesurer des 

signaux électriques. Ne l’utilisez pas à d’autres fins.

Mise à la terre de l’instrument de mesure

La borne de terre de protection de l’oscilloscope doit être connectée à la terre.

Mise à la terre de la sonde

Assurez-vous de connecter le fil de terre ou l’accessoire équivalent de la sonde au potentiel 

de mise à la terre.

Respectez la tension d’entrée maximale

N’appliquez pas une tension supérieure à la tension d’entrée maximale sur la sonde.

Faites attention au choc électrique

N’utilisez jamais la sonde les mains mouillées ou lorsque la sonde elle-même est mouillée. 

Cela pourrait provoquer un choc électrique. Faites attention au choc électrique lorsque vous 

connectez la sonde à l’appareil à mesurer.

N’opérez pas dans des conditions mouillées ou humides

Pour éviter un choc électrique, ne faites pas fonctionner la sonde dans des conditions 

mouillées ou humides.

Évitez les circuits exposés

Pour éviter les chocs électriques, retirez les montres, bagues ou autres bijoux en métal. Ne 

touchez pas les connexions ou composants exposés en présence de courant sur l’appareil.

N’opérez pas dans une atmosphère explosive

Pour éviter les blessures et les risques d’incendie, n’utilisez pas la sonde dans une 

atmosphère de gaz ou des vapeurs inflammables ou explosifs.

Attention aux brûlures et aux engelures

Lorsque la sonde est connectée à un appareil en cours de mesure qui est chaud ou froid, 

ne touchez pas directement la sonde. Dans de telles situations, la sonde sera également 

chaude ou froide et son contact peut provoquer des brûlures ou engelures. Faites également 

attention aux brûlures et aux engelures lorsque vous connectez la sonde à un tel appareil en 

cours de mesure.

N’opérez pas en cas de défaillances suspectées

Arrêtez d’utiliser la sonde si vous pensez qu’elle est endommagée. Consultez votre 

revendeur YOKOGAWA le plus proche.

N’opérez pas avec le câble de signal endommagé

Si le câble de signal est coupé et que le métal interne est exposé ou si une couleur différente 

de la gaine extérieure apparaît, arrêtez d’utiliser le câble.

Ne démontez ou modifiez pas

Ne démontez ou modifiez pas le produit. YOKOGAWA n’assume aucune responsabilité si 

vous démontez ou modifiez le produit.

Regulations and Sales in Various Countries or Regions

Waste Electrical and Electronic Equipment (WEEE)

 

(EU WEEE Directive valid only in the EEA* and UK WEEE Regulation in the UK)

 

This product complies with the WEEE marking requirement. This marking indicates 

that you must not discard this electrical/electronic product in domestic household 

waste. When disposing of products in the EEA or UK, contact your local Yokogawa 

office in the EEA or UK respectively.

 

* EEA: European Economic Area

UKCA Marking

 

This product complies with the UKCA (UK Conformity Assessed) marking.

Authorized Representative in the EEA (AR)

  Yokogawa Europe B. V. is the authorized representative of Yokogawa Test & Measurement 

Corporation for this product in the EEA. To contact Yokogawa Europe B. V., see the separate list of 

worldwide contacts, PIM 113-01Z2.

Disposal

  When disposing of YOKOGAWA products, follow the laws and ordinances of the country or region 

where the product will be disposed of.

1. Overview

  Model 702906 is a passive probe with attenuation ratio of 10:1 for non-isolated BNC input. It can 

be used for oscilloscopes with input impedances of 1 MΩ. The probe operates over a wide range of 

temperature from −40 °C to +85 °C.

2. Configuration and Part Names

 

yellow

green

magenta

cyan

red

orange

light blue

purple

4

3

2

Phase adjustment

screw

1

7

8

5

6

BNC connector

Probe tip

Probe ID pin

Probe cable

9

10

11

No. Standard Parts

Part No.

No. Optional Accessories 

(Sold separately)

Part No.

1. Probe main unit

7.

4Φ conversion adapter

 

(pincher tip end)

B8099NL

2. Pincher tip

B8099MR

3. Safety ground lead

B8099NK

8.

4Φ conversion adapter

 

(ground lead end)

B8099NM

4.

Marker tip (8 colors x 2) –

5.

Adjustment screwdriver –

9. Pincher tip

B9852MN (red)

 

B9852MM (black)

6. Manuals 

(see the table below)

10. Alligator clip adapter (red/black)

758929

11. Fork terminal adapter (red/black)

758921

Manual Title

Manual No.

Description

Model 702906 10:1 Passive Probe 

(Wide operating temperature range, 

for non-isolated BNC input)  

User’s Manual

IM 702906-01EN

This manual. Explains usage, 

specifications, and the handling 

precautions of the 702906.

Model 702906 10:1 Passive Probe 

(Wide operating temperature range, 

for non-isolated BNC input)

IM 702906-92Z1

Document for China

Safety Instruction Manual

IM 00C01C01-01Z1 Safety manual (European languages)

Inquiries

PIM 113-01Z2

List of worldwide contacts

  The “EN”, “Z1”, and “Z2” in the manual number are the language codes.

Model 702906 

10:1 Passive Probe

(Wide operating temperature range,  

for non-isolated BNC input)

8th Edition : May 2022 (YMI)

All Rights Reserved, Copyright © 2014, Yokogawa Test & Measurement Corporation

Printed in Japan

IM 702906-01EN  1/2

Reviews: