For the non-contact thermometer (infrared thermometer), the field of view (spot size) is specified
depending on the distance from the thermometer to the measuring object as shown below.  The
temperature value displayed is the average temperature within the spot size.  To take an accurate
measurement, check the correlation between the size of object and the distance to it.

[Field of View]

* Remarks

ex.) The average temperature of surface of the circle 25 mm in diameter is measured at a distance of 300 mm

away from the measuring object.

* The laser beam points 13mm off to the left from the center of the field of view.  The laser marker functions as a

sighting method and not a sensing element.

* It is possible to take temperatures with this thermometer at a distance of 1,000 mm or more away from the

measuring object, unless there is any obstacle.  However, please note that the measuring field of view enlarges
in proportion to the measuring distance.  This thermometer has an optical resolution of 15:1 [D(Distance to the
measuring object):S(Spot size)].

[For Correct Measurement]

The optical resolution values stated in "Field of View" are at minimum 90% energy.  The size of measuring object
should be sufficiently larger than the field of view (spot size) shown in the above illustration.

Note. If any water drop is on the filter and/or the area around it, the thermometer measures temperature

of the water drop, which results in incorrect measurement.  Wipe up the filter and the area around
it completely before taking measurement.  (See "Maintenance" on page 16)

Field of View

9

OK

NG

INCORRECT

The measuring object is smaller
than the field of view.  The tem-
perature  of  background  influ-
ences on the measuring value.

CORRECT

The measuring object is big-
ger than the field of view.

53008-E  12.5.12 1:12 PM  ページ 8

Summary of Contents for 53008

Page 1: ...product in a place except for home Registration No Equipment Name Trade Name Manufacturer Country of Origin KCC REM IMY EEN326 Emission Thermometer Yokogawa Meter Instruments Corporation Yokogawa Met...

Page 2: ...surface of an ob ject into temperature This thermometer measures the surface temperature of solid and liquid without contacting them The temperature of gas cannot be measured by this thermometer Cont...

Page 3: ...sult in hazardous radiation exposure Safe Usage When operating the instrument be sure to observe the cautionary notes given below to ensure correct and safe use of the instrument If you use the instru...

Page 4: ...alue is near 0 reflect surrounding tempera tures As this thermometer s sensitiv ity to emissivity is fixed at 0 95 0 70 the displayed temperature could differ from the actual temperature of objects wh...

Page 5: ...0 Accuracy 0 95 0 to 200 C 2 C 201 to 500 C 1 Repeatability 1 C of reading value Display resolution 1 C Sighting method Non coaxial laser marker Class 2 HOLD time 15 seconds Continuous measurement mod...

Page 6: ...e is no button to turn ON OFF the power supply Pressing MEASURE button wakes up the thermometer The power supply turns off automatically after 15 seconds absence of pressing any button Name of Compone...

Page 7: ...s a Class 2 laser prod uct as defined by IEC60825 1 Safety of Laser Products Part1 Equipment classi fication and requirements In addition this instrument complies with 21 CFR 1040 10 except for deviat...

Page 8: ...matically after 15 seconds NOR HOLD can be changed into MAX MIN HOLD See Setting on page 15 Continuous Measurement Starting Continuous Measurement qPress and hold both of MEASURE button and SET ENTER...

Page 9: ...away from the measuring object unless there is any obstacle However please note that the measuring field of view enlarges in proportion to the measuring distance This thermometer has an optical resolu...

Page 10: ...ess and hold CALL button for two seconds or more in HOLD Mode refer to page 8 and CALL sign appears on the LCD display In CALL recalling mode the last record of tem perature data and the corresponding...

Page 11: ...page 14 Record Erasing HOLD mode Selections refer to page 15 rWhen each setting is completed it automatically turns to the next setting mode For example when setting of High Limit Temperature for Alar...

Page 12: ...Limit Temperature for Alarm cannot be set at lower temperature than Low Limit Temperature for Alarm Turning ON OFF Alarm Function qWhen the High Limit Temperature setting is completed the setting mod...

Page 13: ...the displayed value as the Low Limit Temperature for Alarm Note The Low Limit Temperature for Alarm cannot be set at higher temperature than High LimitTemperature for Alarm Turning ON OFF Alarm Funct...

Page 14: ...f data Emissivity Emissivity is a value that indicates the infrared energy emitted from the surface of an object Every object has its own emissivity value and it varies depending on the surface condit...

Page 15: ...The measured object is smaller than the field of view Adjust the measuring distance referring to the Field of view described in page 9 The thermometer is affected by a nearby heating source Cut off t...

Page 16: ...rmation or damage Periodical Inspection It is recommended that the thermometer be calibrated annually For further information please contact the vendor from which you purchased the product Battery Bat...

Page 17: ...17...

Page 18: ...18...

Reviews: