- 57 -
4.4.3
Digital I/O
Digital input: Select Open or Close as the Trigger status for the digital input. Connect the
digital input of the Video Server to an external device to detect the current connection status.
Current Status: Display current status of digital input for recognizing whether digital input is
triggered or not.
User select “Close” in trigger condition. If digital input is not triggered, the current status
will show” inactive”; however, if digital input is triggered, the current status will
show ”active”.
User select “Open” in trigger condition. If digital input is not triggered, the current status
will show” active”; however, if digital input is triggered, the current status will
show ”inactive”.
Digital output: Select Active or Inactive to define the output status for the digital output.
Connect digital output pin of Video Server to an external device to determine the current status.
Active: User select “active” in output status. If event is not triggered, NC & COM circuit is
open, NO & COM circuit is close; if event is trigger, NC & COM circuit is close, NO &
COM circuit is open.
Inactive: User select “inactive” in output status. If event is not triggered, NC & COM
circuit is close, NO & COM circuit is open; if event is trigger, NC & COM circuit is open,
NO & COM circuit is close.
Set up the event source as DI on Event > Event settings > Trigger. Please refer to chapter 4.4.1
event setting for detailed information.