MODULE CONFIGURATION TABLE
IMPOrTaNT:
Before starting any configuration, press briefly 23 times to unlock the module. The module will lock again
automatically after 6 hours. It can also be locked immediately with
21
short presses.
Presses*
Time
Reply
11
2 minutes
1 flash
12
4 minutes
2 flashes
13
8 minutes
3 flashes
14
15 minutes
4 flashes
15 30 minutes
5 flashes
16 60 minutes (1 hour) 6 flashes
17
120 minutes (2 hours) 7 flashes
18
240 minutes (4 hours) 8 flashes
19
unlimited
9 flashes
* The flashes are visible on the Stop LED
located on the lower part of the frontal panel
Presses*
Functions
Response on
LED of the module
20
Cycle mode (default) or Comfort/Eco toggle mode
10 flashes
21
Configuration lock
1 flash
23
Configuration unlock
3 flashes
24
Cycle of 6 (default) or 4 commands
4 flashes
28
Restore current state in case of mains power blackout
(active by default)
8 flashes
29
Standard Features (default) or wireless pilot wire
9 flashes
30
Full reset to factory settings
4 flashes
31
State light feedback: On/Off (active by default)
1 flash
DS1054-050B
Press the pushbutton to be connected on the transmitter (E),
5
times*.
The transmitter LED will start flashing for 30 seconds, indicating that the system is waiting for
connection.
* Each press must last less than 0.7 seconds
1
The Led will light up on transmitters only if radio transmission was successful.
P2
P11
DIRECT CONNECTION BETWEEN A YOKIS TRANSMITTER AND AN MFP6ARP
It is essential to involve the transmitter to the module to control a MFP6ARP via a transmitter.
The associated button will work according to the previously configured methods: Cycle (6 or 4 commands) or
Comfort/Eco, with or without timer.
The button can be reconfigured to ensure that pressing it forces the module in Eco mode.
To do this, press the button
10
time quickly and, when the LED flashes, press
4
times.
To return the button standard mode, press it
10
times and then
1
time.
The button can be reconfigured to ensure that pressing it forces the module in Comfort mode.
To do this, press the button
10
time quickly and, when the LED flashes, press
3
times.
To return the button standard mode, press it
10
times and then
1
time.
When the LED of the transmitter blinks, briefly press the "Connect" button of the MFP6ARP (on the front
of the module).
The transmitter LED will stop flashing.
Warning: the receiver must be powered.