19
Yoder YS 480
6. Check to see that the burn grate is properly seated in the firebox.
BURN GRATE
FIREBOX
FIG 15
7. Place 1/8 cup (about a palm full) of pellets on the burn grate.
NOTE: This step is only necessary when the unit is first put into service
or if it runs out of pellets.
8. Reinstall the heat diffuser/drip pan and cooking grates (See FIG 14).
9. Turn the power switch “on.” This starts the combustion air fan and illuminates the
power light. Press the “start” pad on the control panel to activate the auger feed sys-
tem. (The default temperature set point is 350°F). If a higher or lower temperature
setting is desired, use the increase/decrease buttons to set the temperature. This can
be adjusted at any time after the start cycle is activated. (For cool/cold season or high
temperature cooking see the Selectable Heat Up Modes [Page 10]).
Once the start cycle is activated three lines will appear on the display panel from lower
left to upper right indicating “heat up” mode. Once the grate temperature reaches
110°F, the actual grate temperature is displayed, alternating with the mode lines.
If the grate temperature range is exceeded during the “heat up” mode, dashing lines
will appear from upper left to lower right indicating “cool down” mode. Once the target
temperature range is attained the lines will flash horizontal indicating “maintenance
mode”. The controller will display grate temperatures when the set point is between
150 to 495°F When the set point is between 500 to 600°F, the display will show the set
point and not the actual grate temperature.
Summary of Contents for YS 480
Page 1: ...OPERATION INSTRUCTIONS PELLET SMOKER YS 480 24 VERSION 7 2 July 2014...
Page 35: ...34 480 IGNITER AND THERMOCOUPLE COMPONENTS 04 09 10 02 14 08 07 03 12 06 02 01 11 03 05 13...
Page 38: ...37 480 CART 04 12 01 14 12 08 07 03 13 02 09 10 14 13 11 06 05...
Page 40: ...39 480 COMP CART 07 09 08 05 06 14 04 17 16 15 01 11 11 12 13 10 03 02...