INSTALLATION
UNIT MODEL
CODE OF POWER SUPPLY KIT
30A
20A
15A
208-230 VOLT
N/A*
PWRCORD-
230V-20A
PWRCORD-
230V-30A
265-277 VOLT
N/A*
PWRCORD-
265V-20A
N/A*
N/A*
PWRCORD-
265V-30A
PTAC-07K-12B(43)
PTHP-07K-14B(43)
PTAC-09K-12B(43)
PTHP-09K-14B(43)
PTAC-12K-12B(43)
PTHP-12K-14B(43)
PTAC-12K-12B(45)
PTHP-12K-14B(45)
PTAC-15K-12B(45)
PTHP-15K-14B(45)
* Using these cords could result in damage to your unit.
Accessory
Power Supply Cord
or Hard Wire
Wire Clamp
SYSTEM CONFIGURATION
VENTILATION CONTROL
The ventilation control lever is located at left side of
unit, behind front panel.
NOTE:
The vent door shipping hardware must be
removed before using vent control lever. See
Installation Instructions.
When set at CLOSE, only the air inside the room is
circulated and filtered.
When set at OPEN, some outdoor air will be drawn
into room. This will reduce heating or cooling
efficiency.
Energy Tip: Keep the vent control at CLOSE. Room
air will be filtered and circulated.
Ventilation Control Location
ADJUSTING AIR DIRECTION
To adjust air direction:
1) Remove front panel.
2) Remove louver screws that hold louver insert in place (from back side of front panel).
O
3) Turn louver insert and rotate 180 .
4) Replace louver insert.
5) Replace screws and front panel.
Vent Control
(Pull lever
through label
to operate.)
PTAC-07K-12D(43)
PTHP-07K-14D(43)
PTAC-09K-12D(43)
PTHP-09K-14D(43)
PTAC-12K-12D(43)
PTHP-12K-14D(43)
PTAC-12K-12D(45)
PTHP-12K-14D(45)
PTAC-15K-12D(45)
PTHP-15K-14D(45)
N/A*
N/A*
INSTALLATION
HOW TO CONNECT
IMPORTANT: Please read following electrical safety data carefully.
ELECTRICAL SHOCK AND/OR UNIT OPERATION AND DAMAGE HAZARD
Failure to follow this warning could result in personal injury or death and/or unit operation and damage.
* Follow the National Electrical Code (NEC) or local codes and ordinances.
* For personal safety, this unit MUST BE properly grounded.
* Protective devices (fuses or circuit breakers) acceptable for unit installations are specified on the nameplate of
each unit.
* Do not use an extension cord with this unit.
* Aluminum building wiring may present special problems -- consult a qualified electrician.
* When unit is in STOP position, there is still voltage to electrical controls.
* Disconnect power to unit before servicing by:
1) Removing power cord (if it has one) from wall receptacle.
2) Removing branch circuit fuses or turning circuit breakers off at panel.
1) Remove front panel.
2) Remove junction box.
Remove junction box cover by removing three screws from front. Remove junction box by taking out top, rear
and side screws.
3) Connect accessory power supply cord or hard wire connector to unit connector.
Units must be installed using the appropriate
power supply kit. See Table 4 - POWER
CONNECTION CHART.
These connections must be followed.
4) Reinstall junction box and cover.
* Use wire clamp to attach power cord to basepan.
Secure with screws (included).
* Relace junction box and cover with screws
removed from Step 2. Tighten securely.
5) Replace front panel.
6) Connect power to unit.
Remove shipping
screw if present
Shipping Screw Location
Replacing Front Panel
Place tabs over top rail (1). Push Inward at
bottom until panel snaps into place (2).