background image

Thank you for purchasing a YITAHOME product. To ensure correct function and safety, 

please read and follow all the instructions before using the product.

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

1

2

SAFETY GUIDELINES

1. To avoid possible electric shock, turn off the electricity at the main fuse box or circuit panel before you begin installing 
     or servicing the fan.
2. Read and follow all instructions and safety guidelines carefully before installing.
3. Make sure all electrical connections comply with the local codes or ordinances and the National Electrical Code. If you 
     are unfamiliar with electric wiring, please consult a qualified and licensed electrician.
4. Make sure there is sufficient space to rotate the blades of the fan, which is at least seven (7) feet of clearance between 
     the floor and the fan blade tips. The fan should be mounted at least thirty (30) inches from walls and/or other upright 
     structures.
5. 

WARNING:T

he outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 

    100 pounds . To reduce the risk of fire, electric shock or personal injury, mount to the outlet box marked “acceptable for 
    fan support” and use mounting screws provided with the outlet box. The box must be supported directly by the building 
    structure.
6. 

WARNING: 

To reduce the risk of fire, electric shock or personal injury, mount to outlet box marked "acceptable for fan 

    support" and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of 
    lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in 
    doubt.
7. Electrical diagrams are for reference only. Light kits that are not packed with the fan, which must be UL listed and 
     marked suitable for use with the fan model you are installing . Switches must be UL. general-use switches. Refer to the 
     instructions packaged with the light kits and switches for proper assembly.
8. After assembling, check that all connections are firmly secured.
9. After making electrical connections, spliced conductors should be turned upward and pushed up carefully into outlet 
    box. The wires should be placed separately from the grounded conductor and the equipment-grounding conductor on 
    opposite side of the outlet box.
10. 

WARNING:

To reduce the risk of electrical shock and fire , do not use this fan with any solid-state fan speed control 

       device, or rheostat.
11. Do not operate the reverse switch until the fan has come to a complete stop. 12.Do not insert anything into the fan 
       blades while they are rotating.
13. 

WARNING: 

To reduce the risk of personal injury, do not bend the blade brackets (also referred to as "flanges") during 

       assembly or after installation. Do not insert objects into the blades.
14. To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
15. Do not use water or detergent when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be 
       suitable for cleaning.

NOTE:

 The important safety precautions and instructions on the manual are not meant to cover all possible conditions 

               and situations that may occur. It should be understood that common sense and caution are necessary factors 
               during the installation and operation of the fan.

NOTE: 

This product is not intended for use by persons (including children) with reduced physical, sensory or mental 

              capabilities that are different or impaired, or lack of experience and/or knowledge, unless such persons are 
               supervised and/or trained to operate the appliance by a person responsible for their safety.

NOTE: 

Children should be supervised to ensure that they do not use appliances as a toy.

NOTE: 

You must install a switch or circuit breaker that disconnects all power poles of at least 3 mm between each pole.

BEFORE YOU START

Tools Required

Contact a licensed electrician if 

you are not good at performing 

electrical work. It’s the licensed 

electrician who installs the fan, if 

required by the local code. Do not 

use the fan with a dimmer switch. 

Turn off power at breaker.

External Hexagonal 

Wrench

Wire 

Stripper

Phillips 

Screwdrive

Step Ladder

OFF

OFF

Product Instruction

Moun�ng Bracket

Downrod

Canopy

M4x14 Screws

 Hairclip Pin

 Clevis Pin

Fan Motor Assembly

Light Kit

Blade Bracket

Blades

ST5x35 Setscrew

Remote control

Glass shade

MED

1H

STOP

LOW

LIGHT

HI

ON/OFF

2H

4H

8H

Summary of Contents for ZSWY-V1

Page 1: ...7 8084 from Mon Fri 8 00 AM 16 30 PM PST Saturday 8 00 AM 12 00 PMPST or E mail us at after sale cs hotmail com Alternative method to contact us amazon com orders only 1 Log into your amazon account 2 Go to Your Orders and find the purchase 3 Click on Contact Seller CEILING FAN ZSWY V1 ASSEMBLY INSTRUCTIONS TLCFLS 0011 ...

Page 2: ... upward and pushed up carefully into outlet box The wires should be placed separately from the grounded conductor and the equipment grounding conductor on opposite side of the outlet box 10 WARNING To reduce the risk of electrical shock and fire do not use this fan with any solid state fan speed control device or rheostat 11 Do not operate the reverse switch until the fan has come to a complete sto...

Page 3: ...holes should be appropriate expansion screws flat washers nuts provided and tighten with a spanner 2 For wood ceiling secure the mounting bracket to the ceiling that is capable of carrying a load of at least 100lbs 45kgs with two long mounting screws and washers provided Be sure at least 0 12 30mm of the screw is threaded into the support 3 For installing the outlet box secure it directly to the bu...

Page 4: ...ews on the downrod and remove the lifting ball and safety pin 3 Pass the detached downrod through the wire and insert it into the downrod joint Make sure that it is aligned with the hole on the joint Pass through clevis pin and insert the hair clip 1 into the hole of clevis pin 2 then lock the downrod with the screw 3 4 Pass the detached lifting ball through the downrod then insert safety pin to j...

Page 5: ...to the remote control The fan s 4P plug should insert into the the remote control s 4P plug 2 Connect the remote control to the house s power line then connect the remote control s white wire to the house s white wire Connect the remote control s black wire to the house s black wire and connect all the fans green ground wires to the house of ground wires Secure wires 3 Connect the fan motor to the...

Page 6: ...omatically turns off after 2 hours 4H Fan automatically turns off after 4 hours 8H Fan automatically turns off after 8 hours OPERATING YOUR FAN WINTER TIME SUMMER TIME NOTE Wait for the fan to stop before reversing the direction of the blade rotation LIGHT ON OFF Fan Speed H Highest speed M Medium speed L Lowest speed 1 Restore electricity to the outlet box by turning the electricity on at the main f...

Page 7: ...press the FAN ON OFF buttons of transmitters for 5s Then the pairing is successfully activated and all functions will work normally IMPORTANT PAIRING BETWEEN REMOTE AND RECEIVER The first step of pairing must be performed within 30s after turning on the power supply 1 a When pairing multiple fans please ensure the isolation switch or the power supply to the first installed fan is turned off prior to ...

Page 8: ...ng down rod brackets and mounting hardware 6 Confirm the hanger ball is firmly seated in the mounting bracket 7 The ceiling beam must meet the minimum tensile test strength of 30KG for installation 8 Make sure the airfoils and brackets are NOT bent or deformed 9 Confirm the wire connections are not rattling against each other 10 Confirm the fan blades are not cracked If the fan blades are cracked repl...