Instruction
1. Double temperature controllers are beside two sides of the machine and they can be used alone. The left one
can control the temperature of the left vat; the right one can control the temperature of the right one.
2. Shut on the power switch K1, and the green indicator is on, at that time electricity reaches the machine, Rotate
the temperature controller clockwise to the red point, at that time the yellow indicator is on and the green
indicator is off. The green indicator is on and the electric heating tube works again and the temperature goes up
again, It repeats again and again to make sure the temperature is constant in the setting range.
3. According to different food and adjust the needed temperature to get the deal result of making food.
Attention for installation
1. The using voltage of the machine must be coordinated with the supplied voltage.
2. User should install a suitable power switch or air switch.
3. There is a grounding screw behind this oven.The grounding blot should be connected with more than
2.5square mm copper wire according to safety rules for safety sake.
4. Before using this product,please check al parts and power supply and ground connection.
5.
The shell of this machine must be grounded well for safety sake!
Circuit diagram
(
Ⅰ
)14″/ 22″
(III)
22″+Fryer
(II )
29″
S---TEMPERATURE CONTROLLER S1---TEMPERATURE LIMITER
EH---HEATING TUBE HL1---POWER INDICATOR(GN)
HL2---HEATING INDICATOR(YE) SW---MICROSWITCH
E---GROUND PROTECTION
Basic parameter
Trouble
Cause
Resolution
1. Shut on power switch K1, the
indicator is not on
1. The fuse of the power switch is burned.
2. The connection of the power cord is not
well
1. Replace a suitable fuse.
2. Firm power cord.
1. The yellow indicator is not off.
2. The ascend of temperature
can not be controlled.
1. The connection of the indicator is wrong
2. The temperature controller is out of action
1. Correct it with the right connection
2. Replace temperature controller
1. The indicator is not on, but
temperature control is normal
1. The contact of the indicator is not well
2. Indicator is burned
1. Firm connection
2. Replace indicator