YILKAR YK 135 MB Installation Instruction Download Page 10

1

3

5

MONOBLOCK UNIT - YK 135 MB

 1 Piece

310.01.YK135.01

1

MONOBLOCK GROUP - YK 135 MB R1

 1 Piece

500.22.YK135.02

2

AIR SUCTION GRILL COMPLETE - GRAY - YILKAR - 45X22

 1 Piece

501.24.HEIPL.08

3

HOSE - STEEL WIRE - SPIRAL 12 MM

12,5 mt

108.02.HC00M.12

4

AIR CONDITIONING - WEDGE CONNECTION COMPLETE - 20 MM

1 set

504.01.YKMON.01

5

U - DOUBLE - RAIL-EAR 70 CM COMPLETE

3 sets

502.51.UC005.01

6

WICK - LUGGAGE RUBBER

1 ADT

103.02.FT001.01

7

AIR CONDITIONING - HOSE CONNECTION GROMMET

1 Piece

504.01.YKMON.33

4

6

2

7

6

3. Overview

3.1 YK 135 MB Overview

3.1.1. YILKAR Monoblock Un t

EN

Summary of Contents for YK 135 MB

Page 1: ...YK 135 MB YILKAR SSH MT 01 09 EN The right to make changes is reserved Printed in Turkey Y lkar Airconditioned 2023 EN Installation Instruction...

Page 2: ...H MT 01 09 EN The right to make changes is reserved Printed in Turkey Y lkar Airconditioned 2023 00 03 01 2023 H K bra ahin First publication REVISION NO PUBLISH DATE REVISING PERSON REASON FOR REVISI...

Page 3: ...iption 3 1 YK 140 MB Overview 4 3 Monoblock Unit Mounting 4 3 1 YK 140 MB Unit Dimensions 4 3 2 Unit Positioning and Roof Mounting 1 2 1 ECE R 10 2 1 What is the YK 135 MB 2 2 How does it work 2 3 YK...

Page 4: ...ht to make changes is reserved Printed in Turkey Y lkar Airconditioned 2023 5 Commissioning the Air Conditioner 6 Spare Parts 7 Usage and Maintenance Recommendations 6 1 Condenser Spare Parts 6 2 Evap...

Page 5: ...and includes information on safe use of the device Please read this installation instruction carefully in order to fully install Y lkar air conditioner It is recommended to be stored in a safe and cl...

Page 6: ...irst from the date of installation of the product In case the product fails during the warranty period the time spent in repair is added to the warranty period This period starts with the delivery of...

Page 7: ...work only when the engines are turned off Before turning on the air conditioning unit disconnect the battery Please pay attention to the following rules for your own safety 1 2 Security and Legal Reg...

Page 8: ...cle warms up YK 140 MB is universal compact and economical with all its features 2 1 What is YK 135 MB 2 2 How does it work Vehicle roof air conditioners are heat machines that provide passenger therm...

Page 9: ...500 150 gr Evaporator Fan Flow Rate 2000 m h for 2 Blower Motors Condenser Fan Flow Rate 3400 m h for 2 Axial Fans Pressure Switch Low pressure 2 bar Fan Control 15 bar High pressure 25 bar Dimensions...

Page 10: ...L 08 3 HOSE STEEL WIRE SPIRAL 12 MM 12 5 mt 108 02 HC00M 12 4 AIR CONDITIONING WEDGE CONNECTION COMPLETE 20 MM 1 set 504 01 YKMON 01 5 U DOUBLE RAIL EAR 70 CM COMPLETE 3 sets 502 51 UC005 01 6 WICK LU...

Page 11: ...er air conditioning system becomes liquid by giving heat to the environment Evaporator Evaporator is an air conditioning system element that evaporates the R134a refrigerant coming from the condenser...

Page 12: ...24V options for the air conditioning system Relay Board Air Conditioner Hoses It is the pump of the system that compresses the R134a air conditioner gas in the compressor air conditioning system and...

Page 13: ...SER VALVE COMPRESSOR EVAPORATOR High Pressure Line Low Pressure Line In the above assembly diagram the flow direction of the R134a refrigerant and the low high pressure zones are shown on the componen...

Page 14: ...evaporator plastic covers just before this procedure Assembly Step 1 First of all cut the U connection profiles to the dimensions suitable for the roof of your vehicle Assembly Step 2 Assemble the U...

Page 15: ...les to be used for the monoblock unit should be marked on the roof in the vehicle as shown below and it should be mounted to the roof with a drill tipped trapezoidal M5 5x25 screw 24 connection screws...

Page 16: ...nections 3 for evaporator part opening and 1 for grommet 4 3 2 Unit Positioning and Roof Mounting 1760 1280 220 4 3 1 YK 135 MB Unit Dimensions 4 3 Monoblock Unit Mounting Before making any cuts on th...

Page 17: ...the vehicle with the central line on the vehicle in accordance with the mounting criteria Assembly Step 6 For YK 135 MB mark the places to be drilled the details of which are given in the technical dr...

Page 18: ...145 565 660 50 50 465 INSULATION 14 Assembly Step 7 Insulate the bottom of the monoblock unit on the roof of the vehicle with 10 mm PE ARMAFLEX according to the given dimensions MONOBLOCK UNIT BOTTOM...

Page 19: ...vibration damping on the vehicle roof to the drilled holes and insulate with SIMSON ISR 70 03 white mastic Assembly Step 10 Place the monoblock unit on the vehicle roof so that it coincides with the m...

Page 20: ...r part of the monoblock unit to the vehicle roof Insert the bolts from the bottom of the roof into the indicated connection holes and mount them with M10 washers and nuts from the top 16 M10X50 Bolt M...

Page 21: ...ges apply SIMSON ISR 70 03 white sealant around the area where the evaporator unit will be placed Attention should be paid to the sealing of the area between the condenser and the evaporator and it sh...

Page 22: ...MONOBLOCK UNIT TOP VIEW 18 DRIVE DIRECTION EN...

Page 23: ...emoving the existing plugs at the connection points it should be checked whether there is Nitrogen gas in it For the water discharge hose connection the clamps located behind the stage in the evaporat...

Page 24: ...hose types in compliance with SAE J 2064 type E standards available in Y lkar air conditioning system the minimum bending radius of these hoses and the unions used with these hoses are given in the t...

Page 25: ...5 4 4 1 3 Clamp and Plastic Adapters 1 First of all cut the hoses straight one 2 Lubricate the inner part of the hose where the union will pass 3 Put the unions on the hoses properly 2 3 4 Tighten the...

Page 26: ...ors Keep away from the moving elements and hot parts of the vehicle make the assembly by isolating it from all sharp edges and corners where the line will pass Bend the hoses to the minimum bending ra...

Page 27: ...y inserting these nails onto the surface 4 5 Electrical Connections The unit location should be ergonomically chosen as a flat surface in an area accessible to the driver Mounting surface dimensions s...

Page 28: ...o one side of the fuse Place the other M8 cable end on the terminal of the vehicle s battery Complete the assembly of the cabinet set by attaching the nuts with M5 washer Finally connect the D ACC sig...

Page 29: ...nd Circuit Diagram 25 Outdoor Temperature Sensor Internal Temperature Sensor COMPRESSOR GENERATOR TERMINAL BOX 80A Frame GND LOW PRESSURE SWITCH FOUR WAY SWITCH FAN BLOWER ENGINE FAN BLOWER ENGINE CON...

Page 30: ...Back Yellow 0 75 mm 8 Switch Common End Pink 0 75 mm 9 D ACC 1 NU Cable 0 50mm 10 Power Control 2 NU Cable 0 50mm 11 A C 3 NU Cable 0 50mm 12 FAN 1 4 NU Cable 0 50mm 13 FAN 2 5 NU Cable 0 50mm 14 FAN...

Page 31: ...robes in the unit 3 6 2 1 5 4 7 Set temparature Heating on Flap Closed Outside temparature Cooling on Fan speed Inside temparature 7 6 5 2 3 4 1 Flap Open 18 32 SET 21 Increase set temperature Decreas...

Page 32: ...ppears on the screen your air conditioner operates in cooling mode To start the heating mode press the heating button When the heating sign appears on the screen your air conditioner operates in heati...

Page 33: ...ture Sensor Open Circuit Cause of Occurrence The cable may have been cut or the socket may have come off The sensor may be faulty or broken Device Response When an error occurs the system shuts down a...

Page 34: ...missioning the air conditioner Before installing the fiber cover of the air conditioner make sure that the rubbers of the cover are fully inserted then place it parallel to the vehicle roof so that it...

Page 35: ...31 MONOBLOCK UNIT FINAL VIEW DRIVE DIRECTIO N EN...

Page 36: ...The system is vacuumed by the vacuum pump connected by the compressor This process ensures that the air and moisture remaining in the system are discharged from the system with the vacuum pump before...

Page 37: ...COMPACT FILTER 89 ALM X1 PIECE 104 09 CD002 89 4 PIPE 1301 5 8X18 U OUTLET TANK INLET QUICK X1 PIECE 101 12 01301 04 5 SENSOR COMPLETE 2 15 25 BAR 4 Way X1 PIECE 503 04 MDPP4 01 6 GROMMET 89 COMPACT W...

Page 38: ...RFGD04E 3 6 808 X1 PIECES 104 04 4SN01 01 12 CAPITAL BALANCING X1 PIECE 104 10 KD001 01 13 INION 5 8X18 U OR X1 PIECE 108 07 11001 01 14 PIPE 1307 FILTER VALVE ADDITIONAL CONNECTION X1 PIECE 101 12 0...

Page 39: ...MB x1 PIECE 321 02 YK135 02 DIGITAL AIR CONDITIONER CONTROL PANEL x1 PIECE 105 01 KU010 01 TERMINAL BOX x1 PIECE 503 92 KFSET 01 WICK LUGGAGE RUBBER 5 m 103 02 FT001 01 COMPRESS R VALEO TM16 x1 PIECE...

Page 40: ...parts should always be used during repairs Parts not approved by YILKAR may adversely affect the safety and proper operation of the unit In such cases the unit is out of WARRANTY For a fast and accura...

Page 41: ...f inactivity Check the condenser coil regularly and if necessary clean it using compressed air without damaging the aluminum fins When working close to heat exchangers be careful not to injure yoursel...

Page 42: ......

Page 43: ...Vehicle Heating Cooling and Ventilation Systems Phone 90 224 215 53 28 pbx Fax 90 224 215 99 24 Address K kbal kl Mah 580 Sok No 6 Osmangazi BURSA TURKEY www yilkarklima com...

Reviews: