Limit position setting:
1
.
A maximum of six different limit stop positions can be set. The furthest two
positions are called the UP and DOWN limit stop positions. The others are
called the middle limit stop positions;
2
.
When the first limit position is in the UP limit stop position (as below
illustration), all other limit positions can only be set below this position; the
same applies when setting the first DOWN limit stop position, all other limit
stop positions can only be set above this position;
3
.
Every limit stop position can be fine-tuned or deleted separately (The first
limit stop position can only be fine-tuned but can’t be deleted separately. It
can only be deleted by resetting the memory);
4
.
The motor will stop at the next limit stop position after accepting an UP/
DOWN instruction. When it reaches the UP limit stop position, any additional
UP instruction is cancelled out; when it reaches the DOWN limit stop
position, the DOWN instruction is also cancelled;
5
.
Pressing either the UP/DOWN button twice on the transmitter within 1
second will instruct the motor to go directly to the UP/DOWN limit stop
position without stopping at any middle limit stop.
The third limit stop position
The first limit stop position (Up limit position)
The third limit stop position
The third limit stop position
The second limit stop position
All the other
limit positions
can be set below
the first limit
position