5
INSTALLATION INSTRUCTIONS
2967-013A
STEP 1.
Attach the Residue Manager Assembly to th
e planter unit using 3) ½” bolts
and lock nuts.
2967-014A
STEP 1A
.
Attach the 2966-
293 adapter to the CIH row unit using the 1/2” x 3-1/2” bolts
and lock nuts then install the Residue Manager Assembly to the adapter using the 1
/2” x
1-
1/2” carriage bolts and flanged lock nuts.
INSERT 1/2” X 1” BOLT THROUGH
THE LOWER RIGHT HOLE IN ROW
UNIT FROM REAR AND THREAD
INTO THE MOUNT BRACKET
INSERT 1/2” X 1” BOLT
THROUGH THE LOWER LEFT
HOLE IN ROW UNIT FROM THE
REAR AND THREAD INTO THE
MOUNT BRACKET