Device on/off button
Current temperature inside the
left
chamber
Current temperature inside the right chamber
The voltage at the current reaching the device
Temperature scale change button°C/°F
Settings change button
Slider for changing the target temperature inside the left ventricle
Slider for changing the target temperature inside the
right
ventricle
Cooling mode change buttons (MAX / ECO)
Control panel lock button on the device
Battery protection mode change buttons (H/M/L)
Setting the min temperature
Setting the m
ax
temperature
Setting the compressor start delay after starting the device (in minutes)
Left ventricular hysteresis setting - the compressor will start after exceeding the sum of the
set device temperature and hysteresis temperature.(example - cooling temperature set
on the device: -20°C, hysteresis temperature: +2°C, compressor restart temperature: -18°C)
Settings enabling leveling of differences between the real temperature of the inside of the left
ventricle of the device and the temperature set on the control panel (example - cooling
temperature of the left ventricle of the device: 0°C, actual temperature inside the ventricle:
-5°C,
temperature to be set to level the diffe5°C)
Setting delaying / accelerating the compressor off after reaching the temperature set on the
left ventricle control panel
Change the application theme
Changing the application language
Restoring the default settings of the application
Disconnecting the Bluetooth connection
Right ventricular hysteresis setting - the compressor will start after exceeding the sum of the
set device temperature and hysteresis temperature
.
(example - cooling temperature set on the
device: -20°C, hysteresis temperature: +2°C, compressor restart temperature: -18°C)
Settings enabling leveling of differences between the actual temperature of the inside of the
right chamber of the device and the temperature set on the control panel (example - cooling
temperature of the right chamber set on the device: 0°C, actual temperature insidethe
chamber: -5°C, temperature to be set to level the diffe5°C)
Setting delaying / accelerating the compressor off after reaching the temperature set on the
right ventricle control panel
-4°C