Up To 20 Feet (6 m)

Up To 20 Feet (6 m)(GD Models)

21 To 100 Feet (6 to 30 m)(GD Models)

21To 50'Feet (6 to 15 m)

51 To 100 Feet (16 to 31 m)

101To 200 Feet (31 to 61 m)

Contactor Control

Amperage Control

Table 2-1.Cord Length And Size

Cord

Length

Conductor

size*

No.16
No.14
No.12
No.14
No.12
No.10

Cord

Length

Conductor

Size

Up To 200 

Feet (61m)

No.16

*AWG -American Wire Gauge

3. REMOTE AMPERAGE

On  most  welding  power  sources  or  welding  generators, 
when a Remote Foot Control is used, the Remote Foot Con-
trol functions as a fine amperage adjustment of the Amper-
age on the welding power source or welding generator. For 
example:  If  the  Amperage  Adjustment  Control  on  the  weld-
ing  power  source  or  welding  generator  is  set  at  the  mid-
point  position,  the  Remote  Foot  Control  provides  (from  its 
minimum to maximum positions) fine adjustment of one half 
of the welding power source or welding generator output. If 
full adjustment of the maximum output of the welding power 
source  or  welding  generator  from  the  Remote  Foot  Control 
is  desired,  rotate  the  Amperage  Adjustment  Control  on  the 
welding power source or welding generator to the maximum 
position. On some welding power sources or welding gener-
ators the Amperage Adjustment Control is inoperative when 
a Remote Foot Control is used.