background image

Section 3. Troubleshooting

 

 

Section 4. Reference

 

 

Control Menu 

 

 

DMX Protocol

 

 

Specification

 

Control Menu 

 

MENU1:

 

Dmx:15CH

 

(PRESS ENTER)

 

Dmx:15CH

 

Add:xxx

 

DMX512: Press UP/DOWN to set up 1-512 add value, 

always  remember  press  ENTER  to  save  your 

settings.

 

Test

 

Auto

 

AUTO:    Press ENTER to active auto running and to 

save the settings.

 

MENU2:

 

Test

 

(PRESS ENTER)

 

Test

 

Sound

 

SOUND:    Press ENTER to active auto running and 

to save the settings.

 

MENU3:

 

   Manual

 

(PRESS ENTER)

 

Manual

 

CH01

xxx

 

 

Manual

 

CH15 :xxx

 

Manual:  UP/  DOWN  adjust  value  0-255,  press 

ENTER  to  save.  (CH01-CH15  stands  for  15 

channels, same function as DMX console.)

 

Option

 

Pan:Yes

 

X/Pan 

clockwise 

and 

anti-clockwise 

setting: 

UP/DOWN  to  choose  Yes/No,  press  ENTER  to 

choose  and  save.  Choose  Yes  is  X  anti-clockwise 

running.

 

MENU4:

 

   Option

 

(PRESS ENTER)

 

Option

 

Tilt:Yes

 

Y/Tilt clockwise and anti-clockwise setting: UP/DOWN 

to choose Yes/No, press ENTER to choose and save. 

Choose Yes is Y anti-clockwise running.

 

 

Probable cause(s)

 

Remedy

 

No power to fixture

 

Check power cables

 

Primary fuse blown

 

Replace fuse

 

No  response  from 

fixture  when  power 

is applies

 

Secondary 

fuse 

blown

 

Replace fuse

 

Controller 

not 

connected

 

Connect controller

 

Incorrect 

addressing  of  the 

fixtures

 

Check address setting on fixture and controller

 

Bad 

data 

link 

connection

 

Inspect  cables  and  correct  poor  connections 

and/or broken cables.

 

Conflict 

between 

tracking  and  vector 

control

 

Eliminate scene cross-fade on controller 

 

Data 

link 

not 

terminated

 

Insert termination plug in output of last fixture

 

Fixture  resets  but 

does  not  respond 

correctly 

to 

controller(DMX 

mode operation)

 

Defective  fixture  or 

devices 

transmitting on link

 

Bypass  fixtures  one  at  a  time  until  normal 

operation is regained:unplug both connectors and 

connect them directly together

 

Colors  cannot  be 

mixed

 

Random 

color 

mixing is on

 

Turn off random color mixing 

 

Fixture  does  not 

reset correctly

 

Electronic 

or 

mechanical failure

 

Contact service technician

 

Lamp  missing  or 

blown

 

Disconnect fixture and replace lamp

 

No light, lamp cuts 

out intermittently,or 

burns out too 

quickly

 

Fixture  or  lamp  is 

too hot

 

Allow  fixture  to  cool.  If  problem  persists,contact 

service technician

 

Summary of Contents for YR-W1004H

Page 1: ...LED MINI WASH MOVING Model YR W1004H...

Page 2: ...1 Getting Started Unpacking Safety Instruction Section 2 Set Up Installation Controlling Board Machine Connection Section 3 Troubleshooting Troubleshooting Section 4 Reference Control Menu DMX Protoc...

Page 3: ...MOVING WASH LIGHT range Carefully unpack the box and check the contents to ensure that all parts are present and in good conditions If anything looks as if it has been damaged in transit notify the sh...

Page 4: ...it allows to connect to 4 fixtures at most Always disconnect from the power source before servicing or replacing fuse lamp and be sure to replace with same fuse lamp size and type Cut off power befor...

Page 5: ...place Running Temp 0 C 35 C Weight 3 4kg Size 201 4 196 317 4mm In order to keep life span of machine Better to turn off and cool down it after continuous using for 4 6 hours Section 2 Set Up Installa...

Page 6: ...near dimmer from dark to bright CH8 G dimmer Green linear dimmer from dark to bright CH9 B dimmer Blue linear dimmer from dark to bright CH10 A dimmer Amber linear dimmer from dark to bright CH11 U di...

Page 7: ...between pins 2 3 of the last fixture They are also readily available from specialty retailers MENU4 Option PRESS ENTER Option Sound xx Sound active sensitivity adjust setting UP DOWN adjust value 0 25...

Page 8: ...xture Check power cables Primary fuse blown Replace fuse No response from fixture when power is applies Secondary fuse blown Replace fuse Controller not connected Connect controller Incorrect addressi...

Reviews: