background image

Controlling Board

 

1

2

3

4

5

6

 

1. Display

 

Display menu and selected function.

 

Button

 

MENU

 

  switch menu function  

 

UP

 

On function: page up

 

On numerical value: increase value

 

DOWN

 

On function: page down

 

On numerical value: reduce value

 

ENTER

 

  Settle selected function and value

 

 

3. DMX signal input

 

Control model by DMX signal

please use 3pin

/5pin

 XLR signal cable.

 

4. DMX Signal output

 

Transfer DMX signal to next model, please use 3pin

/5pin 

  XLR signal cable.

 

5. Power output

 

Connect to obtain power

, Neutric power connector is optional

 

(attention

please use connect to stated voltage.)

 

6

Power input

 

Connect to obtain power, Neutric power connector is optional

 

 
 

 

 

Machine Connection

 

 

Cable Connectors

 

Cables  must  have  a  male  XLR  connector  on  one  end  and  a  female  XLR  connector  on  the 

other end.

 

A word on termination: DMX is a resilient communication protocol, 

however errors still occasionally occur. Termination reduces signal errors, and therefore best 

practices include use of a terminator in all circumstances. If you are experiencing problems 

with  erratic  fixture  behavior,  especially  over  long  signal  cable  runs,  a  terminator  may  help 

improve performance.

 

To  build  your  own  DMX  Terminator:  Obtain  a  120-ohm,  1/4-watt 

resistor, and wire it between pins 2&3 of the last fixture. They are also readily available from 

specialty retailers

.

 

 

 

 

Master-Slave control model

 

Set  up  one  fixture  as  Master  fixture(triggering),other  fixtures  as  slave 

fixtures(receiving  trigger  signals).Set  up  all  fixtures

  same 

address  value  or 

following DMX controller performance(Attention: all fixtures use the same DMX 

channel-7 or 11CH)

 

 

 

Maximum 8 PCS fixtures connected by Daisy chain connection. 